• Title/Summary/Keyword: Dielectric breakdown characteristics

Search Result 329, Processing Time 0.025 seconds

A study on insulation Characteristics of XLPE by various additives (다양한 첨가제에 따른 가교폴리에틸렌의 절연특성 분석)

  • Song, Sang-Min;Kim, Gyu-Sik;Son, Won-Keun;Ryu, Boo-Hyung;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.193-196
    • /
    • 2001
  • XLPE is occasionally happened to deteriorate cable insulation characteristics. It is happened to do a breakdown state by the degradation of electrical characteristic and electrical breakdown strength. I prepared TR-XLPE (Tree-Retardant XLPE) as adding various additives to prevent its states. Various additives are treeing retardants, anti-oxidants. Treeing retardants three kinds of aromatic compounds as adding each additive. Anti-oxidants use quinone compound and cresol compound as adding each additive. In order to observe each electrical characteristics, I measured breakdown strength, relative dielectric constant$({\varepsilon}_r)$, dielectric loss tangent$(tan{\delta})$. TR-XLPE specimens as adding treeing retardants and anti-oxidants enhance breakdown strength, ${\varepsilon}_r$, $tan{\delta}$ than pure XLPE.

  • PDF

SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field (불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Breakdown Characteristics of Dry Air under 362 kV GIB (362 kV GIB 내에서 건조공기의 절연파괴 특성)

  • Han, Ki-Son;Ju, Hyung-Jun;Yoon, Jin-Yul;You, Hong-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics (강유전체에서의 전계분포 및 절연파괴)

  • 신병철;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF

Electrical properties variations of nitrided, reoxided MOS devices by nitridation condition (질화와 재산화 조건에 따른 모스 소자의 전기적 특성변화)

  • 이정석;이용재
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.343-346
    • /
    • 1998
  • Ultra-thin gate oxide in MOS devices are subjected to high-field stress during device operation, which degrades the oxide and exentually causes dielectric breakdown. In this paper, we investigate the electrical properties of ultra-thin nitrided oxide (NO) and reoxidized nitrided oxide(ONO) films that are considered to be promising candidates for replacing conventional silicon dioxide film in ULSI level integration. We study vriations of I-V characteristics due to F-N tunneling, and time-dependent dielectric breakdown (TDDB) of thin layer NO and ONO depending on nitridation and reoxidation condition, and compare with thermal $SiO_{2}$. From the measurement results, we find that these NO and ONO thin films are strongly depending on its condition and that optimized reoxided nitrided oxides (ONO) films show superior dielectric characteristics, and breakdown-to-change ( $Q_{bd}$ ) performance over the NO films, while maintaining a similar electric field dependence compared to NO layer.

  • PDF

A Study on the DC Dielectric Breakdown Properties of Epoxy Composites Containing Methacrylate/Polyurethane (Methacrylate/Polyurethane이 함유된 Epoxy 복합재료의 직류 절연 파괴 특성에 관한 연구)

  • Kim, M.H.;Kim, K.H.;Lee, D.J.;Ga, C.H.;Shin, S.K.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1357-1359
    • /
    • 1994
  • In this study, in order to improve the problem that dielectric breakdown strength decrease remarkably at high temperature, simultaneous interpenetrating polymer networks method was Introduced so that epoxy insulating material could have stable temperature characteristics and stable dielectric breakdown characteristics at whole temperature range. So network structure of epoxy/$SiO_2$ composite material was changed by adding MA and MA/PU into epoxy resin. DC voltage is applied into the specimen fabricated by this method, and then the result was compared and investigated.

  • PDF

Dielectric Breakdown Characteristics of $Al_2O_3$ Filled DGEBA/MDA/SN System ($Al_2O_3$가 충전된 DGEBA/MDA/SN 계의 절연열화 특성)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.209-211
    • /
    • 1996
  • The dielectric breakdown characteristics of DGEBA/MDA/SN system filled with $Al_2O_3$ under AC high electric field were investigated. As the filler content increased, the dielectric breakdown strength increased, but decreased at higher filler content than 5 phr. The probability of defects such as air bubbles, peel between filler and epoxy resin insulator, etc. increase proportionally to filler contents. Fillers blockade the treeing growth and relax the electric field at the tip of electrical tree and the treeing propagation rate decreases so that the strength showed higher strength at lower filler content than 5 phr.

  • PDF

Electrical Insulating Characteristics of Mixing Epoxy Resin (혼합 에폭시 수지의 전기 절연특성)

  • 홍경진;정우성;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.95-97
    • /
    • 1990
  • This study investigated electrical characteristic of solids and liquid epoxy resins by measuring dielectric breakdown and dielectric loss when epoxy resins were exposed to a mixing cure. It was found that mixing epoxy resins were superior to dielectric breakdown and hardness and has shorter curing time compare with those of pure liquid epoxy resins.

Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Song, Ki-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.264-269
    • /
    • 2010
  • This paper presents the analysis of the dielectric characteristics of a hot $SF_6$ gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real $SF_6$ gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.