• 제목/요약/키워드: Dielectric barrier discharge (DBD)

검색결과 167건 처리시간 0.022초

Surface treatment of sol-gel bioglass using dielectric barrier discharge plasma to enhance growth of hydroxyapatite

  • Soliman, Islam El-Sayed;Metawa, Asem El-Sayed;Aboelnasr, Mohamed Abdel Hameed;Eraba, Khairy Tohamy
    • Korean Journal of Chemical Engineering
    • /
    • 제35권12호
    • /
    • pp.2452-2463
    • /
    • 2018
  • Surface treatment of sol-gel bioglass is required to increase its biomedical applications. In this study, a dielectric barrier discharge (DBD) plasma treatment in atmospheric pressure was performed on the surface of [$SiO_2-CaO-P_2O_5-B_2O_3$] sol-gel derived glass. The obtained bioglass was treated by plasma using discharge current 12 mA with an exposure period for 30 min. The type of discharge can be characterized by measuring the discharge current and applied potential waveform and the power dissipation. Apatite formation on the surface of the DBD-treated and untreated samples after soaking in simulated body fluid (SBF) at $37^{\circ}C$ is characterized by Fourier transform infrared spectroscopy (FTIR), X-Ray diffraction (XRD), inductively coupled plasma (ICP-OES) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS). We observed a marked increase in the amount of apatite deposited on the surface of the treated plasma samples than those of the untreated ones, indicating that DBD plasma treatment is an efficient method and capable of modifying the surface of glass beside effectively transforming it into highly bioactive materials.

여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화 (Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

Effects of Hydrophilic Surface Treatment on SUS Substrates by Using Dielectric Barrier Discharge

  • Joa, Sang-Beom;Kang, In-Je;Yang, Jong-Keun;Lee, Heon-Ju
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.458-458
    • /
    • 2012
  • Fuel Cell is used stacking metal or polymer substrate. This hydro property of substrate surface is very important. Usually, surface property is hydrophilic. The surface oxidation of SUS is investigated through plasma treatments with an atmospheric-pressure dielectric barrier discharge (DBD) for increasing hydrophilic property. The plasma process makes an experiment under various operating conditions of the DBD, which operating conditions are treatment time, plasma gas mixture ratio, the plasma source supply frequency. Two kinds of SUS substrate, SUS-304 and SUS 316L, were used. Discharge frequency has a crucial impact on equipment performance and gas treatment. After the plasma treatment of a SUS plate, highly improved wettability was noted. But, when high oxygen supply, the substrate damaged seriously.

  • PDF

평판형 전극으로 구성된 유전체 배리어 방전 반응기를 이용한 톨루엔 저감 특성 (Removal of Gaseous Toluene using a Plate-type Dielectric Barrier Discharge Reactor)

  • 박재홍;조윤신;윤기영;변정훈;황정호
    • 한국대기환경학회지
    • /
    • 제24권6호
    • /
    • pp.641-648
    • /
    • 2008
  • A plate-type dielectric barrier discharge (DBD) reactor was designed and tested for removal of gaseous toluene. The DBD reactor consisted of 9 parallel plate electrodes, four of which were grounded. An AC voltage of rectangular waveform ($5{\sim}8.5kV$, $60{\sim}1,000Hz$), was applied to the other five electrodes. The gaseous toluene passed through the DBD reactor and its concentration was measured by a real-time gas analyzer. The carbon monoxide (CO) and carbon dioxide ($CO_2$) which were produced by decomposition of toluene in the DBD reactor, were sampled and analyzed by a micro gas chromatography. The maximum toluene removal efficiency was 51.4%.

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

음이온 생성을 위한 표면 유전체장벽방전의 설계조건 연구 (A Study of The Surface Dielectric Barrier Discharge Design Conditions for Generating Negative Air Ions)

  • 신상문;김정윤;김종수;최재하;최원호
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.114-122
    • /
    • 2014
  • This paper describes a study of the design conditions of a planar surface dielectric barrier discharge (DBD) reactors for generating negative air ions. The capacity of negative air ion generated by the surface DBD reactor is affected by the shape, area ratio and the location of the discharge and induction electrodes of it. To study the optimal design conditions of DBD reactors, the electrodes printed on the substrate of a PCB board is utilized to conduct kind of experiments: the distance of the each electrode along with the X-Y axis, the area ratio of the discharge electrode to induction electrode, and the symmetrical and asymmetrical location of two electrodes. The ion generation capacity is inverse proportional to the gap increases along with X-Y axis. And the optimum ion concentration generated by the ionizer was inspected when the electrodes area ratio was 3 and 5 times of the symmetrical and asymmetrical experimental condition respectively.

유전체 장벽 방전에 의한 벤젠의 분해 (Decomposition of Benzene by Dielectric Barrier Discharge)

  • 이용훈;이재호;박동화
    • 공업화학
    • /
    • 제18권3호
    • /
    • pp.213-217
    • /
    • 2007
  • 본 연구에서는 유전체장벽방전을 이용하여 휘발성 유기화합물의 일종인 벤젠의 분해 경향과 분해 생성물의 선택성에 대해서 연구하였다. 유전체장벽방전의 공정변수에 따른 벤젠의 분해율과 분해 생성물의 선택성을 높이기 위해서 반응기 내부에 촉매(H-ZSM-5, Na-Y)를 사용하였다. 실험은 대기압에서 수행하였으며, 방전전압, 체류시간, 농도 등의 공정변수에 따른 분해율을 조사하였다. 유전체 장벽방전만을 사용하는 방법과 비교하여 여기에 촉매를 동시에 사용하는 하이브리드 방전이 같은 전압과 체류시간조건에서 보다 효과적인 벤젠의 분해 방법임을 확인하였다.

2계면 플라즈마 방전시스템(DBD System)의 특징 및 소독제로서 방전수의 사용가능성에 대한 연구 (Study on the Characteristics of Dielectric Barrier Discharging System and Usability as a Disinfectant)

  • 류승민;박희경;이봉주
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.529-536
    • /
    • 2004
  • Innovated technique to inactivate microorganisms has been developed. This technique uses plasma discharge in 2-phase (Air-Water). Dielectric Barrier (two phase) Discharging system is able to produce new oxidants for microorganisms. Products from discharging are $HNO_2$, $NO_2{^-}$, $HNO_3$, $NO_3{^-}$ and ozone but many other radicals can be generated as well. DBD water has low concentration of ozone (about 0.5mg/L), $NO_2{^-}$, $NO_3{^-}$ (about 10mg-N/L, 20mg-N/L respectively) and lots of $H^+$. These products play an important role in oxidation. Oxidation power by KI titration methods is approximately equivalent to $50mg-O_3/L$. Surprisingly stored DBD water could oxidize KI and maintain stable pH (about pH3) even after several days. Stored DBD water for 5 days has also more than 4log disinfection power to E. coli. However, DBD water cannot be used for drinking water directly due to it's toxicity. Additional process to neutralize pH and decrease toxicity must be applied.

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

평판형 유전체 장벽 방전 반응기에서 Acetonitrile의 분해 특성 (Decomposition of Acetonitrile by Planar Type Dielectric Barrier Discharge Reactor)

  • 송영훈;김관태;류삼곤;이해완
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.105-112
    • /
    • 2002
  • A combined process of non-thermal plasma and catalytic techniques has been investigated to treat toxic gas compounds in air. The treated gas in the present study is $CH_3$CN that has been known to be a simulant of toxic chemical agent. A planar type dielectric barrier discharge(DBD) reactor has been used to generate non-thermal plasma that produces various chemically active species, O, N, OH, $O_3$, ion, electrons, etc. Several different types of adsorbents and catalysts, which are MS 5A, MS 13X, Pt/alumina, are packed into the plasma reactor, and have been tested to save power consumption and to treat by-products. Various aspects of the present techniques, which are decomposition efficiencies along with the power consumption, by-product analysis, reaction pathways modified by the adsorbents and catalysts, have been discussed in the present study.