• Title/Summary/Keyword: Dielectric Plate

Search Result 183, Processing Time 0.023 seconds

Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Ionizer and Dielectric-substance (이오나이저 및 유전체 방식을 도입한 다층 다단 다공성 플레이트 시스템의 집진특성)

  • Yoa, Seok-Jun
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.63-72
    • /
    • 2013
  • The main purpose of this study is to analyze the collection characteristics of multi-layer multi-stage porous plate system with ionizer and dielectric-substance experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with experimental parameters such as applied voltage, inlet velocity, stage number and inlet particle concentration, etc. In results, for multi-layer multi-stage porous plate system of inflow type, at 5 stage and $v_{in}$=2.58 m/s, the pressure drop becomes lower 15 $mmH_2O$ as 95 $mmH_2O$ than that of non-inflow type system. It is estimated that for the present system with ionizer and dielectric-substance, the collection efficiency represents 98.5% showing higher 5.2% comparing to that of multi-layer multi-stage porous plate system without ionizer and dielectric-substance at 5 stage, $v_{in}$=2.58 m/s and inlet concentration $3g/m^3$(fly ash).

Uncertainty and Compensation on the cell for Measurement of the Solid Permittivity Materials (고체 유전율 측정용 cell의 불확도 분석과 보상)

  • Kim, Han-Jun;Kang, Jeon-Hong;Yu, Kwang-Min;Hyun, Lee-Sei;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.482-483
    • /
    • 2007
  • For measurement of dielectric constants, the commercial parallel plate electrodes system with guard-ring electrode have been widely used up to now. The capacitance derived from the parallel plate electrodes capacitor with guard-ring electrode is calculated by the equation of ($C={\epsilon}\;{\cdot}\;\frac{area\;of\;electrod}{distance\;between\;electrodes}$). Therefore, in parallel plate electrode capacitor, the diameter of the guarded electrode, the gap size between guarded electrode and guard ring, and distance between two active electrode should be measured precisely to calculate dielectric constants from the measured capacitance. Consequently their mechanical measurement uncertainties are directly contributed. Especially the air-gap between the electrodes and dielectric specimen at the system must be existed and the measurement error derived from the air-gap is impossible to evaluate as measurement uncertainties. In this study, we analyze the uncertainty of the commercial dielectric constant test cell using 3 kinds CRMs.

  • PDF

Vertical β-Ga2O3 Schottky Barrier Diodes with High-κ Dielectric Field Plate (고유전율 필드 플레이트를 적용한 β-Ga2O3 쇼트키 장벽 다이오드)

  • Se-Rim Park;Tae-Hee Lee;Hui-Cheol Kim;Min-Yeong Kim;Soo-Young Moon;Hee-Jae Lee;Dong-Wook Byun;Geon-Hee Lee;Sang-Mo Koo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.298-302
    • /
    • 2023
  • In this paper, we discussed the effect of field plate dielectric materials such as silicon dioxide (SiO2), aluminum oxide (Al2O3), and hafnium oxide (HfO2) on the breakdown characteristics of β-Ga2O3 Schottky barrier diodes (SBDs). The breakdown voltage (BV) of the SBDs with a field plate was higher than that of SBDs without a field plate. The higher dielectric constant of HfO2 contributed to the superior reduction in electric field concentration at the Schottky junction edge from 5.4 to 2.4 MV/cm. The SBDs with HfO2 field plate showed the highest BV of 720 V, and constant specific on-resistance (Ron,sp) of 5.6 mΩ·cm2, resulting in the highest Baliga's figure-of-merit (BFOM) of 92.0 MW/cm2. We also investigated the effect of dielectric thickness and field plate length on BV.

A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide (평행판 도파관을 이용한 유전율 측정 방법)

  • Cho, Gyo-Yeong;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.199-203
    • /
    • 2012
  • This paper introduces a simple new procedure approach to determine the permittivity of dielectric slabs. The method uses a parallel plate waveguide which supports a TEM mode. The presence of the dielectric slab placed at the bottom of the waveguide makes the speed of the TEM wave slower. The relationship between the change of the speed and the permittivity of the dielectric slab allows the determination of the permittivity. The relationship is analyzed electromagnetically, and the results of measurements are in good agreement with the analysis.

Robust inverse identification of piezoelectric and dielectric effective behaviors of a bonded patch to a composite plate

  • Benjeddou, Ayech;Hamdi, Mohsen;Ghanmi, Samir
    • Smart Structures and Systems
    • /
    • v.12 no.5
    • /
    • pp.523-545
    • /
    • 2013
  • Piezoelectric and dielectric behaviors of a piezoceramic patch adhesively centered on a carbon composite plate are identified using a robust multi-objective optimization procedure. For this purpose, the patch piezoelectric stress coupling and blocked dielectric constants are automatically evaluated for a wide frequency range and for the different identifiable behaviors. Latters' symmetry conditions are coded in the design plans serving for response surface methodology-based sensitivity analysis and meta-modeling. The identified constants result from the measured and computed open-circuit frequencies deviations minimization by a genetic algorithm that uses meta-model estimated frequencies. Present investigations show that the bonded piezoceramic patch has effective three-dimensional (3D) orthotropic piezoelectric and dielectric behaviors. Besides, the sensitivity analysis indicates that four constants, from eight, dominate the 3D orthotropic behavior, and that the analyses can be reduced to the electromechanically coupled modes only; therefore, in this case, and if only the dominated parameters are optimized while the others keep their nominal values, the resulting piezoelectric and dielectric behaviors are found to be transverse-isotropic. These results can help designing piezoceramics smart composites for various applications like noise, vibration, shape, and health control.

Uncertainty Analysis and Compensation of the Cell for Permittivity Measurement of Solid Materials (고체재료의 유전율 측정용 Cell의 불확도 분석과 보상)

  • Kim, Han-Jun;Yu, Kwang-Min;Kang, Jeon-Hong;Han, Sang-Ok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • The commercial parallel plate electrodes system with guard-ring electrode have been widely used for measurement of dielectric constants of solid materials. And the specification of the electrodes system is about 1 % of measurement uncertainty. This measurement uncertainty is only estimated the error come from mechanical measurements such as the area of the electrodes and the gap between the electrodes except the error come from the air gap between the electrodes and dielectric specimen. Because it is impossible to measure the air gap. This study analyze the total measurement uncertainties of the commercial dielectric constant test cell using 3 kinds of Standard Reference Materials. As a results, the total measurement uncertainty is much bigger than 1 % and the most of the uncertainty can be reduced by compensation of the error values evaluated in this study.

Investigation of buckling behavior of functionally graded piezoelectric (FGP) rectangular plates under open and closed circuit conditions

  • Ghasemabadian, M.A.;Kadkhodayan, M.
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.271-299
    • /
    • 2016
  • In this article, based on the higher-order shear deformation plate theory, buckling analysis of a rectangular plate made of functionally graded piezoelectric materials and its effective parameters are investigated. Assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for the buckling analysis of an FGP rectangular plate are established. In addition to the Maxwell equation, all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. Considering double sine solution (Navier solution) for displacement field and electric potential, an analytical solution is obtained for full simply supported boundary conditions. The accurate buckling load of FGP plate is presented for both open and closed circuit conditions. It is found that the critical buckling load for open circuit is more than that of closed circuit in all loading conditions. Furthermore, it is observed that the influence of dielectric constants on the critical buckling load is more than those of others.

Simplified Ground-type Single-plate Electrowetting Device for Droplet Transport

  • Chang, Jong-Hyeon;Kim, Dong-Sik;Pak, James Jung-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The current paper describes a simpler ground-type, single-plate electrowetting configuration for droplet transport in digital microfluidics without performance degradation. The simplified fabrication process is achieved with two photolithography steps. The first step simultaneously patterns both a control electrode array and a reference electrode on a substrate. The second step patterns a dielectric layer at the top to expose the reference electrode for grounding the liquid droplet. In the experiment, a $5{\mu}m$ thick photo-imageable polyimide, with a 3.3 dielectric constant, is used as the dielectric layer. A 10 nm Teflon-AF is coated to obtain a hydrophobic surface with a high water advancing angle of $116^{\circ}$ and a small contact angle hysteresis of $5^{\circ}$. The droplet movement of 1 mM methylene blue on this simplified device is successfully demonstrated at control voltages above the required 45 V to overcome the contact angle hysteresis.

In-line Variable Attenuator Based on the Evanescent Wave Coupling Between a Side-polished Single-mode Fiber and an Index Matched Dielectric Plate

  • Kim, Kwang-Taek;Kim, Hyo-Kyeom
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.17-20
    • /
    • 2004
  • An in-line variable attenuator has been proposed and demonstrated exploiting a side-polished single-mode (SM) fiber evanescently coupled with an index matched dielectric plate. The attenuation can be controlled by fine mechanical sliding of the index matched dielectric plate. We have achieved 49 ㏈ dynamic range and very low excess loss of 0.2 ㏈ at 1550 nm wavelength. The measured polarization dependent losses (PDL) were 0.1, 0.2, and 0.4 ㏈ at 10, 20, and 30 ㏈ attenuation, respectively. Wavelength sensitivity was measured to be -0.017/nm ㏈ at 20 ㏈ attenuation.