• Title/Summary/Keyword: Diaphragms

Search Result 161, Processing Time 0.026 seconds

Experimental Study on the Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Kuen;Lee, Jong-Sung;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.345-348
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light gas gun can develop an extremely high pressure in a very short interval of time. This can be employed efficiently in the application of ultra-high pressure liquid jets. In general, the two-stage light gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. The first diaphragm is installed downstream of the high pressure tube and the second, downstream of the compression tube. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at diaphragm opening. It is found that the rupture pressure of the first diaphragm has a dominant influence on projectile velocity. It is also observed that at pressures greater than 14 bar, the pressure in the launch tube exceeds that in the compression tube.

  • PDF

Aging Characteristics of Low Pressure LPG Regulators for Domestic Use (가정용 LPG 저압조정기의 경년특성에 관한 연구)

  • Kim Young-Gyu;Kwon Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1999
  • Experimental works were carried out to evaluate how the lapse of time affects the performance characteristics and the service life of low pressure LPG regulators for domestic use. Experimental results showed that the operating pressure of safety devices deviated from the opening pressure value and the closing pressure value from just 1 year after service, and the operating pressure of regulators used for 7${\~}$8 years notably deviated from the reference value of the adjusting pressure and the closing pressure. And the material properties of springs and diaphragms deteriorated after 5${\~}$6 years of service. Thus, it is estimated that low pressure LPG regulators have approximately 6 years of service life. However, it is highly recommended that regulators exceeding 5 years of service should be replaced for the safety of consumer and accident prevention even if they are operating normally.

  • PDF

Experimental Study on a Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Keun;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.10-15
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light-gas gun can produce an extremely high pressure in a very short interval of time. In general, the two-stage light-gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. This can be employed efficiently in the application of ultra-high pressure liquid jets. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at the frist diaphragm opening. In the present study result was found that the rupture pressure of the first diaphragm has a dominant influence on piston acceleration.

Fabrication and Performance Evaluation of Flat-Type Multilayer Piezoelectric Ceramic Ultrasonic Transmitter (평판형 적층 세라믹 초음파 압전 트랜스미터의 제조와 성능 평가)

  • Na, Yong-hyeon;Lee, Min-seon;Cho, Jeong-ho;Paik, Jong-hoo;Lee, Jung Woo;Jeong, Young-hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.207-212
    • /
    • 2019
  • A flat-type piezoelectric ceramic ultrasonic transmitter was successfully fabricated for application in acoustic devices with cone-free diaphragms. The transmitter, possessing a center frequency of 40.6 kHz, exhibited a higher displacement characteristic for a multilayer type compared with a single layer type. Surface roughness treatment of an Al elastic diaphragm influenced a slight increase (1.1 dB) in the sound pressure level (SPL) at $10V_{rms}$ due to the enlarged surface area. The fabricated multilayer piezoelectric ceramic ultrasonic transmitter showed increasing SPL with increasing input voltage, with a maximum SPL of approximately 123.6 dB at $10V_{rms}$. This implies a doubly increased SPL density of $3.6dB/mm^3$, superior to that of a commercial open-type transmitter with a cone.

Experimental Study on Two-Seam Cold Formed Square CFT Column to Beam Connections with Asymmetric Diaphragms (상하 이형 다이아프램으로 보강된 2심 냉간성형 각형 CFT 기둥-보 접합부의 실험적 연구)

  • Oh, Heon Keun;Kim, Sun Hee;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.35-45
    • /
    • 2013
  • The concrete-filled tube column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. It suggests that pipe should be produced by welding two sides together where two shapes are joined after a channel is pre-welded onto the three sides in order to form an internal diaphragm. The upper diaphragm of the connection used the horizontal plate and the lower diaphragm used the Vertical plate. This research performed 6 monotonic tension experiments describing the connection upside and downside in order to evaluate the structural capability of the offered connection. And the cyclic loading experiment was performed about 2 T-Type column to beam connections. As to the experimental result edge cutting geometry, there was no big effect. An increase in the number of holes of the plate ultimate strength was increased by 5% and The thickness of the plate increases, the maximum strength was increased by 4%. T-Type connections until it reaches the plastic moment showed a stable behavior.

The Effect of Phrenic Nerve Paralysis After Pediatric Cardiac Surgery on Postoperative Respiratory Care (소아 심혈관 수술 후 발생한 횡격신경마비가 술후 호흡관리에 미치는 영향)

  • 윤태진;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1118-1122
    • /
    • 1996
  • From January 1990 through December 1995, 43 patients underwent diaphragmatic plication for the management of phrenic nerve palsy .complicating various pediatric cardiovascular surgery. Their mean age at plication was 11.1 months and sex ratio was 31 males to 12 females. In order of decreasing incidence, the primary cardiovascular procedures included modified Blalock-Taussig shunt (7), total correction for the Tetralogy of Falloff (7), arterial switch operation (6), unifocalization for the pulmonary atresia with VSD (3), modified Fontan operation (3), VSD patch closure (3) and others. The involved sides of diaphragm were right in 17, left in 2) and bilateral in 3. Extensive pericardial resection with electocauterization of resected margin was thought to be the most common cause of phrenic nerve palsy (20). The interval between primary operation and plication ranged from the day of operation to 98 days (median 11 days). The methods of plication were central pleating technique(plication with phrenic nerve branch preservation) in 41, and other technique In 2. 10 patients died after plication (7: early, 3; late), and the causes of death were thought to be unrelated to plication itself. Among the 36 early survivors, extubation or cessation of positive pressure ventilation could be accomplished between 1 and 24 days postoperatively(mean : 4.5). Cumulative follow-up was 92 patient years without major complications. Postoperative follow-up fluoroscopy was performed in 6 patients, and the location and movement of plicated diaphragms were satisfactory in 5 patients. We concluded that diaphragmatic plication with preservation of phrenic n rve branch could lead to cessation of positive pressure ventilation and complete recovery of diaphragmatic function in the long term, unless the phrenic nerve was irreversibly damaged.

  • PDF

Characteristics of Electrolyzed Water Manufactured from Various Electrolytic Diaphragm and Electrolyte (전기분해 격막 및 전해액에 따른 전해수의 특성 비교)

  • 정진웅;김종훈;김병삼;정승원
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2003
  • This study was carried out to investigate the efficacy of surface sterilization and the physicochemical properties of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Physical properties of electrolyzed water manufactured from the diaphragm system were the most effective at the following conditions; the distance between diaphragms was 1.0 mm and the supplying rate of 20% NaCl was 6 mL/min. The ORP, HClO content and pH at above conditions were 1,170 mV, 100 ppm and 2.5, respectively. And two stage electrolyzed system was more effective than one stage electrolyzed water manufactured from non-diaphragm system, with 4 mL/min supplying rate of 20% NaCl, was similar to the most effective diaphragm system. But ORP, HClO content and pH were abut 800 mV, 200 ppm and 9 level, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORP of 750 mV in non-diaphragm system and 1,150 mV in diaphragm system, and HClO content of 100 ppm. Twelve kinds of microorganism tested were sterilized within 30 seconds from initial total counts of 10$\^$5/∼10$\^$6/cfu/ml by electrolyzed water. Though the ORP and HCIO contents of electrolyzed water manufactured from various electrolyte were higher in order of NaCl>KCl>CaCl$_2$, there were no difference between the electyolytes in the efficacy of sterilization. Salmonella typhi and Vibrio Proteolyticus were also sterilized by electrolyzed water manufactured from elctrolytes of NaCl CaC1$_2$and KCl

Multimode fiber-optic pressure sensor based on dielectric diaphragm (유전체 다이아프램을 이용한 다모드 광섬유 압력센서)

  • 김명규;권대혁;김진섭;박재희;이정희;손병기
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.3
    • /
    • pp.220-226
    • /
    • 1997
  • An optical intensity-type pressure sensor has been fabricated by coupling multimode optical fiber with 100 nm-Au/30 nm-NiCr/150 nm-$Si_3N_4/300 nm-SiO_2/150 nm-Si_3N_4$ optical reflection layer supported by micromachined frame-shape silicon substrate, and its characteristics was investigated. For the application of $Si_3N_4/SiO_2/Si_3N_4$ diaphragm to the optical reflection layer of the sensor, NiCr and Au films were deposited on the backside of the diaphragm by thermal evaporation , respectively, and thus optical low caused by transmission in the reflection layer could be decreased to a few percents. Dielectric diaphragms with uniform thickness were able to be also reproduced because top- and bottom-$Si_3N_4$ layer of the diaphragm could automatically stop silicon anisotropic etching. The respective pressure ranges in which the sensor showed linear optical output power-pressure characteristics were 0~126.64 kPa, 0~79. 98 kPa, and 0~46.66 kPa, and the respective pressure sensitivities of the sensor were about 20.69 nW/kPa, 26.70 nW/kPa, and 39.33 nW/kPa, for the diaphragm sizes of 3$\times$3 $\textrm{mm}^2$, 4$\times$4 $\textrm{mm}^2$, and 5$\times$5 $\textrm{mm}^2$, indicating that the sensitivity increases as diaphragm size increases.

  • PDF

Long-Term Behavior of Square CFT Columns with Diaphragm (격막이 설치된 각형 CFT 기둥의 장기거동에 관한 연구)

  • Kwon Seung-Hee;Kim Tae-Hwan;Kim Yun-Yong;Kim Jin-keun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1025-1032
    • /
    • 2005
  • This paper presents experimental and analytical studies on long-term behavior of square CFT columns with diaphragm. In order to investigate the effect of the diaphragm on the long~term behavior, experiments for six specimens with two diaphragms and three different column length, and three-dimensional finite element analysis for each specimen have been performed. The finite element models considering the interface behavior between the steel tube and the inner concrete were verified from comparison of the test results with the analysis results. From the test and the analysis results, the following conclusions were obtained. The confinement effect created by the diaphragm does not depends on column length and influences only a part of the whole column that is from the end to the depth which is the same to the width of the column. The shortening of the column with diaphragm which covers more than a half of the cross sectional area of the inner concrete is the same as that of the column under a load applied on the steel tube and the entire section of the inner concrete.

Effect of Puromycin Aminonucleoside on Podocyte P-Cadherin (Puromycin aminonucleoside의 사구체 족세포 P-cadherin에 대한 영향)

  • Ha, Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.79-85
    • /
    • 2013
  • Purpose: To test whether the expression of P-cadherin, a component of slit diaphragms between podocyte foot processes, would be altered by puromycin aminonucleoside (PAN) in a cultured podocyte in vitro. Methods: Rat glomerular epithelial cells (GEpC) were cultured with various concentrations of PAN. The distribution of P-cadherin was examined with a confocal microscope. Western blotting and reverse transcriptase-polymerase chain reaction (RT-PCR) were used to measure the change in P-cadherin expression. Results: This study found that P-cadherin was concentrated in the inner and peripheral cytoplasm with high concentrations of PAN under immunofluorescence views. Western blotting of GEpC revealed that PAN induced a decrease of P-cadherin in dose- and time-dependent manners. A high dose ($50{\mu}g/mL$) of PAN decreased P-cadherin expression by 21.9% at 24 h (P <0.05) and 31.9% at 48 h (P <0.01) compared to those without PAN. In RT-PCR, high concentrations ($50{\mu}g/mL$) of PAN also decreased P-cadherin mRNA expression, similar to protein suppression, by 23.5% at 48 h (P <0.05). Conclusion: Podocytes exposed to PAN in vitro concentrated P-cadherin internally, and reduced P-cadherin mRNA and protein expression. This could explain the development of proteinuria in experimental PAN-induced nephropathy.