• Title/Summary/Keyword: Diaphragms

Search Result 161, Processing Time 0.027 seconds

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.10 no.3
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

Seismic assessment and retrofitting of Pombalino buildings by pushover analyses

  • Meireles, Helena;Bento, Rita;Cattari, Serena;Lagomarsino, Sergio
    • Earthquakes and Structures
    • /
    • v.7 no.1
    • /
    • pp.57-82
    • /
    • 2014
  • The heritage value of the mixed wood-masonry 18th century Pombalino buildings of downtown Lisbon is recognized both nationally and internationally. The present paper focuses on the seismic assessment of global response and retrofitting of a typical Pombalino building by nonlinear static analyses, performed by the research software Tremuri, which is able to model 3D configurations. The structure is modelled using nonlinear beams for masonry panels, while in case of the internal walls (frontal walls) an original formulation has been developed in order to take into account their specific seismic behaviour. Floors are modelled as orthotropic membrane finite elements: this feature allows to simulate the presence of both flexible and rigid diaphragms, being the first ones more representative of the original state while the second ones of retrofitted configurations. Seismic assessment has been evaluated by applying nonlinear static procedure and comparing the performance of different configurations (by considering various retrofitting strategies). Finally, assuming a lognormal cumulative distribution, fragility curves are obtained to be representative of Pombalino buildings: the most important application of such curves is for seismic risk and loss estimation analyses.

Performance Evaluation of Free breathing Fuel Cell by using Synthetic Jet Air Blower (Synthetic Jet Air Blower를 이용한 Free Breathing 연료전지의 성능 평가)

  • Choi, Jong-Pil;Ku, Bo-Sung;Jang, Jae-Hyuk;Seo, Young-Ho;Kim, Byeong-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2834-2838
    • /
    • 2008
  • An free breathing proton exchange membrane fuel cell (PEMFC) was developed. This paper presents a study of the several effect on the performance of a fuel cell such as air flow rate, opening ratio, and cathode structures. Especially, an air flow rate is critical condition to improve the fuel cell performance. In this paper, we developed a synthetic jet micro air blower to supply high stoichiometric air. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. In comparison with free convection fuel cells, the forced-convection fuel cell which equipped synthetic jet micro air blower brings higher performance and stability for long term test. Also, power consumption of the synthetic jet micro air blower is under 0.3W. The results show that the maximum power density was $188mW/cm^2$ at $400mA/cm^2$. The maximum power density was higher 40% than power density of free convection fuel cell.

  • PDF

Elastomeric High Barrier Materials for Vehicle (고차단성 자동차 부품용 고무소재)

  • Kim, Jin-Kuk
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.2-9
    • /
    • 2011
  • Permeability to gases and vapors is an important function in tires, rubber tubes and diaphragms. It mainly depends on the rubber material. Generally, permeability increases in the following order: silicone rubber > NR > EPDM > SBR > NBR > FPM > ECO > IIR. And, for an elastomer permeability is also very much dependent on compounding. Many research works are reported in the area of gas permeability for formed rubber,$^{1-7}$ however, few studies are found for unformed elastomer products. Incorporation of nano-particles, use of thermoplastic elastomers and applying high barrier multilayer coatings are the main approaches to obtain a high barrier elastomeric product. In this paper, barrier article for vehicle is introduced.

Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm

  • Choi, Sung-Mo;Yun, Yeo-Sang;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.303-317
    • /
    • 2006
  • The connection with combined cross diaphragm is developed for the connection of square CFT column and steel beam and proposed to be used for the frame with asymmetric span length. The structural characteristics of this connection lie in the penetration of the beam flange in the direction of major axis through the column for the smooth flow of stress. The purpose of this study is to analyze the dynamic behavior and stress flow of suggested connection and to evaluate the resistance to shock of connection. Four T-type CFT column-to-beam specimens; two with combined cross diaphragm and the others with interior and through diaphragms, the existing connection types, were made for cyclic load test guided by the load program of ANSI/AISC SSPEC 2002. The results show that the proposed connection is more efficient than existing ones in terms of strength, stress flow and energy absorption and satisfies the seismic performance required in the region of weak/moderate earthquakes.

Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections

  • Huang, Zhi;Jiang, Li-Zhong;Zhou, Wang-Bao;Chen, Shan
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1217-1238
    • /
    • 2016
  • Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.

A Study on the Strength of H Beam-to-Rectangular Tube Column Connections with Exterior Diaphragms by Simplified Tension Test (단순 인장 실험에 의한 외부 스티프너를 갖는 각형 강관기둥과 H형강보 접합부의 최대내력에 대한 연구)

  • Park, Jong Won;Kang, Hae Kwan;Lee, Sang Hoon;Kim, Young Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.25-35
    • /
    • 1998
  • A moment connection of H beam-to-rectangular tube column with external stiffeners was proposed. A formula to predict the ultimate strength of the connection was derived based on the yield line mechanism. Experimental investigation was performed to determine the applicability of the connection type and the strength formula. The ultimate strengths computed by the formula agreed well with the experimental values.

  • PDF

Structural Characteristic of Beam-to-Column Connections in Rectangular CFT Structures Considering Concrete Filling (충전성을 개선한 각형CFT 기둥-보 접합부의 구조 특성)

  • Park, Je Young;Lee, Myung Jea
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • CFT structures require a diaphragm to prevent buckling of steel at connections. An outer diaphragm has better concrete filling than a through diaphragm due to a large bore, but due to the larger size than the through diaphragm, it has poorer constructability and cooperation with building equipment. The building structure has a floor slab that was unified with the upper diaphragm, so the outer diaphragm was placed at the upper bound. Moreover, the through diaphragmwas placed at the lower connection to avoid obstruction of the building equipment. The CFT structure with the improved concrete filling showed the same structural behavior as the CFT structure with the use of the same type of diaphragms at the upper and lower connections.

Development of Synthetic-Jet based micro air pump for BOP system of mobile fuel cell (모바일 연료전지 BOP를 위한 Synthetic-Jet 기반 마이크로 에어펌프 개발)

  • Kim, K.S.;Choi, J.P.;Koo, B.S.;Jang, J.H.;Seo, Y.H.;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.247-251
    • /
    • 2008
  • This paper presents a micro air pump actuated by PZT actuator (synthetic jet actuator) for air supply for micro fuel cells. The synthetic jet actuators are usually created by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, in/outlet channel and PZT diaphragms. To design the micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. A prototype of the micro air pump, with a size of $mm{\times}mm{\times}mm$, was fabricated by PDMS replication process and was conducted performance test. To control the PZT actuator, we used the SP4423 micro chips that can be amplified input voltage to reduce the controller size and the power consumption. With a voltage of 3V at 100Hz, the air pump's pumping pressure is 600pa and its power consumption is only 0.1mW.

  • PDF

Lateral Load Distribution for Prestressed Concrete Girder Bridge (PSC 거더교의 하중횡분배에 관한 연구)

  • Park, Moon-Ho;Park, Jung- Hwal;Kim, Jin- Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.2
    • /
    • pp.157-166
    • /
    • 2001
  • The purpose of this study is to examine the accuracy of the code provisions on lateral load distribution factors of prestressed concrete girder bridges. Most designers in Korea use the lever method or lateral load distribution formula in the existing design codes. However, the methods do not account for the effect of bridge skew or direction of diaphragm. Therefore, this study analysed the prestressed concrete girder bridge with grillage model for various girder spacings, directions of diaphragms, span lengths, and skews, and compared the results with those of existing design code. It has been found that lateral load distribution factors were proportional to the girder spacing while they were not significantly affected by the change of span length, direction of diaphragm, and skew. For bending moments, lateral load distribution factors from the grillage analysis were 60%~68% of those from Korean bridge design code. Therefore, the code provisions result in very conservative design. For support reactions, however, lateral load distribution factors from the grillage analysis were slightly greater than those from Korean bridge design code. Therefore, the capacity of bearings of the bridge with a large skew should be determined by grillage analysis.

  • PDF