• Title/Summary/Keyword: Diaphragm material

Search Result 98, Processing Time 0.029 seconds

Deflection Analysis of MCA/Si diaphragm for MEMS (MEMS용 MCA/Si diaphragm 구조의 변위해석)

  • Kim, Jae-Min;Lee, Jong-Choon;Yoon, Suk-Jin;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.372-375
    • /
    • 2003
  • MCA deflection control is a important technology for the development of MEMS applications. In this study, deflection analysis at the MLA/Si diaphragm was investigated by Finite Element Method. Analysis of Si diaphragm combined with MCA has been implemented into the ANSYS (Solid5 and Solid45). On the basis of this structure, deflection versus MCA number of layers has been modelled and MCA/Si contact area characteristics with different diaphragm conditions were analyzed. Consequently, it is expected that fabrication technology of MCA/Si diaphragm could be usefully applied for the fabrication process of high-performance piezoelectric MEMS devices.

  • PDF

Simulation Results of Piezoelectric Microspeakers due to Structural Changes (구조변화에 따른 압전형 마이크로스피커의 모의해석)

  • Jeong, Kyong-Shik;Ur, Soon-Chul;Cho, Hee-Chan;Yi, Seung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.327-327
    • /
    • 2007
  • This paper reports the simulation results of piezoelectric microspeakers due to structural changes(diaphragm materials, corrugation width and electrode shapes). When we compared the dependence of diaphragm material properties, the microspeaker with LTO(Low Temperature Oxide) diaphragm shows higher deflection than that of silicon nitride diaphragm, even though the resonant frequencies are almost same in both cases. In case of circular-electrode microspeaker, the deflection of diaphragm is about $16\;{\mu}m$ at 20 V, and it decreases as the corrugation width is decreased. However, the deflection of diaphragm with the square-electrode reveals almost twice times higher value at the same applied voltage than the circular one, and it increases as the corrugation depths are decreased from $30\;{\mu}m\;to\;10\;{\mu}m$. The first resonant frequency of microspeakers present about 1.8 kHz in circular-electrode and 1.2 kHz in square-electrode, respectively.

  • PDF

Rubber Material Development and Performance Evaluation of Diaphragm Seal for Steam Generator Nozzle Dam

  • Woo, Chang-Su;Song, Chi-Sung;Lee, Han-Chil;Kwon, Jin-Wook
    • Elastomers and Composites
    • /
    • v.55 no.3
    • /
    • pp.222-228
    • /
    • 2020
  • Rubber materials, used in nuclear power plants, need high heat-oxidation resistance to curing or cracking under a heat aging environment. This is because they are applied to environments with high temperature, high humidity, and radiation exposure. Nuclear radiation causes additional hardening or degradation, therefore, rubber materials need radiation resistance that satisfies the general and any accidental conditions produced in the power plant. Therefore, in this study, we developed a rubber material with excellent heat and radiation resistance for the diaphragm seal of a nuclear steam generator nozzle dam. The rubber material greatly improved the reliability of the steam generator nozzle dam. In addition, 30 inch and 42 inch diaphragm seals were manufactured using the developed rubber material. A nozzle dam was installed in a nuclear power plant and tested under the same conditions as a steam generator to evaluate safety and reliability. In the future, the performance and safety of diaphragm seals developed through field tests of nuclear power plants will be evaluated and applied to currently operating and new nuclear power plants.

The Effect of Curvature Radius and Material of Diaphragm on the Valve Opening Time in Diaphragm Type S/R Valve (S/R 밸브에서 격막의 곡률반경과 재료가 밸브 개구시간에 미치는 영향)

  • Cheon, Heung-Kyun;Hwang, Jae-Gun;Cho, Tae-Seok;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2961-2966
    • /
    • 2007
  • When the pressure at the weak spot established at a certain part of a high pressure vessel or piping system exceeds a design pressure, this weak spot is burst, and the pressurized gas emitted through the weak spot will cause a compression wave system. In this connection, in the present study, an experimental study by using a conventional shock tube facility is performed to estimate the effects of the material of diaphragm, curvature radius and thickness of materials on the valve opening time in diaphragm. Pressure sensor having 500kHz in natural frequency is installed at 35mm downstream of the rupture diaphragm to measure the static pressure history of propagating and being accumulated compression wave. 4 kinds of materials are used as diaphragm that is aluminium, copper, stainless steel and zinc. The diaphragm radii of curvature R are ${\infty}$, 120mm and 60, respectively. And the depth for $90^{\circ}$ groove is 0.04mm. It is found that the smaller the tensile strength and elongation of the rupture diaphragm is, the smaller the radius of curvature of the rupture diaphragm is, and for the same conditions the thinner the thickness of the rupture diaphragm is, the shorter the valve opening time becomes. Also, the tensile strength, elongation and the radius of curvature of the rupture diaphragm for the same conditions are smaller, the maximum pressure rise caused by the coalescences of the compression wave is smaller. Finally the pressure ratio is higher, the valve opening time is shortened and gradient of pressure increment is more steepen.

  • PDF

Thick-Film Strain-gage Ceramic-Pressure Sensor (세라믹 다이어프램을 이용한 후막 스트레인 게이지 압력센서)

  • 이성재;박하용;민남기
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.987-993
    • /
    • 2001
  • In this paper, we presents the construction details and output characteristics of a thick film piezoresistive strain gage. The thick film was printed on the ceramic diaphragm back side by screen printing and cured at 850$^{\circ}C$. The strain distribution and deflection on ceramic diaphragm were performed with finite-element method(FEM tool ANSYS-5.3). Various thick film strain gage characteristics were analysed, including nonlinearity, hysteresis, stability and sensitivity of thick film strain gages.

  • PDF

Studying Acoustical Properties of Micro-Speaker as a Function of Diaphragm Material (진동판의 재질에 따른 마이크로스피커의 음향특성연구)

  • Oh Sei-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.222-228
    • /
    • 2006
  • The acoustical property of micro-speaker had been investigated as a function of the diaphragm material in this study. Young's modulus and the density of material is deeply related to the determination of sound velocity and stiffness. As a result, it was appeared that the resonance frequency of micro-speaker was PEI < PPS < PET < PEN. This experimental result was in an excellent agreement with the theoretical one. The increasing ratio of sound pressure level to the frequency between 20Hz and the resonance frequency ($f_s$) and the high resonance frequency ($f_h$) were not affected by the diaphragm material.

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Cho, Hee-Chan;Yi, Seung-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.556-561
    • /
    • 2008
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small and constant at low frequency region and shows about 70 dB at 10 kHz. However, in case of a compressively stressed composite diaphragm, the SPL of the fabricated microspeakers shows higher output pressure than those of a tensile-stressed diaphragm. It produces more than 66 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with $20V_{peak-to-peak}$, sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone. From the experimental results, it is superior to have a compressively composite diaphragm in order to produce a high SPL in piezoelectric microspeaker.

Computer Simulation of Deformation Behavior of the Rubber Diaphragm (고무 다이아프램의 변형거동 전산해석)

  • Cho, Seong-Do-Seong;Kim, Wan-Doo
    • Elastomers and Composites
    • /
    • v.35 no.1
    • /
    • pp.4-11
    • /
    • 2000
  • A rubber diaphragm is a critical element of accumulators. The material of a diaphragm is nitrile rubber so as to recover and adjust the large deformation under external pressure fluctuation. The performance of accumulators is influenced by the deformation behaviors of the diaphragm. A large deformation behavior of the diaphragm has been investigated using the commercial finite element program MARC K7.1. The several elastic moduli have been used in linear analysis and Ogden's coefficients have been used in non-linear analysis. As a result, it has been shown that the deformation behavior with a elastic modulus of $0.3 kg/mm^2$ is similar to the behavior of non-linear analysis. And, the modified diaphragm shape to reduce the stress concentration has been proposed.

  • PDF

A Study on Performance Characteristics with the Control System of CNG Regulator (CNG 레귤레이터의 제어 방식에 따른 성능특성 연구)

  • Seo, Ji-Won;Yang, Jeong-Jik;Kim, Jin-Ho;Lim, Jong-Wan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2017
  • The domestic vehicles remodeling the "CNG Bi-fuel Kit" are mostly in operation with installing the mechanical regulator applying the Diaphragm. However, due to the material characteristics of Diaphragm and characteristics of mechanical pressure control method, various problems are happening. This study tries to deduce the improvement plan through the checking of performance characteristics according to the pressure control method of CNG regulator and progress of comparative analysis. According to the test result, the decompression method applying the Diaphragm has advantage compared to the method applying the Piston. Furthermore, it was confirmed that through the electronic pressure control, it is possible to improve the general performance of the regulator.

A Study on Fabrication of Piezorresistive Pressure Sensor (벌크 마이크로 머쉬닝에 의한 다결정 실리콘 압력센서 제작 관한 연구)

  • 임재홍;박용욱;윤석진;정형진;윤영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.677-680
    • /
    • 1999
  • Rapid developing automation technology enhances the need of sensors. Among many materials, silicon has the advantages of electrical and mechanical property, Single-crystalline silicon has different piezoresistivity on 야fferent directions and a current leakage at elevated temperature, but poly-crystalline silicon has the possibility of controling resistivity using dopping ions, and operation at high temperature, which is grown on insulating layers. Each wafer has slightly different thicknesses that make difficult to obtain the precisely same thickness of a diaphragm. This paper deals with the fabrication process to make poly-crystalline silicon based pressure sensors which includes diaphragm thickness and wet-etching techniques for each layer. Diaphragms of the same thickness can be fabricated consisting of deposited layers by silicon bulk etching. HF etches silicon nitride, HNO$_3$+HF does poly -crystalline silicon at room temperature very fast. Whereas ethylenediamice based etchant is used to etch silicon at 11$0^{\circ}C$ slowly.

  • PDF