• 제목/요약/키워드: Diameter ratio

검색결과 3,070건 처리시간 0.033초

길이 대 직경 비와 입구 모서리 반경에 따른 회전 오리피스의 송출 특성 (Discharge Characteristics of Rotating Orifices with Length-to-Diameter Ratios and Inlet Corner Radii)

  • 하경표;강세원;고상근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.957-966
    • /
    • 2000
  • The effect of rotation on the discharge coefficient of orifices with various length-to-diameter ratios and two different inlet corner radii was studied. Length-to-diameter ratios of the orifices range from 0.2 to 10, while the inlet shapes are square edged, or round edges of radius-to-diameter ratio of 0.5. From the experiment, we found that rotational discharge coefficient and Rotation number, when based on ideal exit velocity of the orifice considering momentum transfer from the rotor, describe the effect of rotation very well. In this study, the discharge coefficients of rotating orifices are shown to behave similar to those of the well-known non-rotating orifices. For both rotating and non-rotating orifices, the discharge coefficients increase with the length-to-diameter ratio until a maximum is reached. The flow reattachments in the relatively short orifices are responsible for the increase. The coefficient then decreases with the length-to-diameter ratio due to the friction loss along the orifice bore. The length-to-diameter ratio that yields maximum discharge coefficient, however, increases with the Rotation number because the increased flow-approaching angle requires larger length-to-diameter ratio for complete reattachment. The length-to-diameter ratio for complete reattachment is shorter for round edged orifices than that of square edged orifices by about a unit length-to-diameter ratio.

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향- (A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice -)

  • 이병화;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

보텍스 생성실 지름비가 에너지 분리에 미치는 영향 (The Effect of a Vortex Chamber Diameter Ratio on Energy Separation)

  • 유갑종;이병화;최인수
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.667-673
    • /
    • 2001
  • As an alternative cooling method to reduce environmental hazard, vortex tubes have been studied for energy separation into cold and hot streams. Hence, the experiments were carried out systematically to find the best ratio of vortex chamber diameter to tube diameter. Also, the work was don to investigate how inlet pressure and geometric ratios of vortex tube affected temperature differences at tow needs as ell as cooling capacity and cooling efficiency. The result showed that the maximum temperature differences at the both ends and the maximum cooling efficiency were obtained when the ratio of vortex chamber diameter was about 1.45, while the inlet pressure ws not higher than 0.7 MPa.

  • PDF

충격파관 저압실/고압실 직경비에 따른 압력변동에 대한 수치해석 (A Numerical Study on Pressure Variation in a Shock Tube by Changing the Diameter Ratio of Low-Pressure (Driven) to High-Pressure (Driver) Part)

  • 왕위엔강;김철진;손채훈;정인석
    • 한국연소학회지
    • /
    • 제21권4호
    • /
    • pp.16-22
    • /
    • 2016
  • Pressure and temperature variations in a shock tube have been studied numerically by changing the diameter ratio of a driven part to a driver part. There are five cases where the adopted diameter ratios are 40%, 50%, 60%, 80%, and 100% respectively. The diameter of the driver part remains unchanged meanwhile the shock tube driven part diameter increases from 40% to 100% of the driver part. In the 100% ratio case, the driver part and driven parts have the same diameter of 66.9 mm. As the diameter ratio decreases, the pressure in the shock tube and available test time are increased.

전.후방 캔 압출공정의 성형특성 연구 (A Study on the Forming Characteristics of Forward and Backward Extrusions)

  • 심지훈;최호준;옥정한;함병수;황병복
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.86-92
    • /
    • 2005
  • In this paper a forward-backward can extrusion process are analyzed by using rigid-plastic FEM simulation. FEM simulation is conducted to investigate forming characteristics such as deformation modes fur different process parameters. Design parameters such as thickness ratio, punch angle, friction factor and diameter ratio are selected to study the effect of them on the pattern of material flow. The analysis is focused mainly on the influences of the design factors on deformation pattern in terms of forming load, extruded length ratio and volume ratio. It is known for the simulation that the forming load, the length ratio and the volume ratio increase as the thickness ratio (TR), the wall thickness in forward direction to that in backward direction, decreases. The various punch angles have slight influence on the forming load. length ratio and volume ratio. However friction factor have little effect on the forming characteristics such as the forming load, volume ratio and so on. In addition the forming load increases as diameter ratio (DR), the outer diameter of a can in forward direction to that in backward direction, increases. Furthermore the extruded length ratio is lowest with a certain value of DR=0.85 among diameter ratios. Pressure distribution exerted on the die-material interface is illustrated schematically.

복부대동맥류의 직경비에 따른 정상유동 및 맥동유동에 관한 수치적 연구 (A Numerical Study on the Steady and Pulsatile Flow with Various Diameter Ratios of Abdominal Aortic Aneurysm)

  • 모정하;박상규
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.920-928
    • /
    • 2003
  • The objective of the present study was to investigate the characteristics of flow and wall shear stress under steady and pulsatile flow in the aneurysm. The numerical simulation using the software were carried out for the diameter ratios ranging from 1.5 to 3.0, Reynolds number ranging from 900 to 1800 and Womersley number, 15.47. For steady flow, it was shown that a recirculating vortex occupied the entire bulge with its core located closer to the distal end of the bulge and the strength of vortex increased with increase of the Reynolds number and diameter ratio. The position of a maximum wall shear stress was the distal end of the aneurysm regardless of the Reynolds number and diameter ratios. For the pulsatile flow, a recirculating flow at the bulge was developed and disappeared for one period and the strength of vortex increased with the diameter ratio. The maximum values of the wall shear stress increased in proportion to the diameter ratio. However, the position of a maximum wall shear stress was the distal end of the aneurysm regardless of the diameter ratios.

우리나라 소나무 및 일본잎갈나무의 지역별 형상비 추정 (Estimating Tree Shape Ratio by Region for Pinus Densiflora and Larix Kaempferi in Korea)

  • 강진택;고치웅;임종수;이선정;문가현
    • 한국산림과학회지
    • /
    • 제108권4호
    • /
    • pp.600-609
    • /
    • 2019
  • 본 연구는 우리나라 소나무와 일본잎갈나무의 지역별 형상비를 고려한 임분 밀도 관리의 필요성과 관리 방안을 제시하기 위하여 수행되었다. 전국을 대상으로 소나무 2,112본, 일본잎갈나무 2,030본을 벌채하여 흉고직경 및 수고, 지하고를 측정하고 지역별 형상비(수고/흉고직경)를 비교 분석하였다. 소나무의 형상비는 강원지방 소나무 72.3%, 중부지방소나무 64.0%, 소나무 평균 70.8%로 강원지방소나무가 중부지방소나무에 비하여 높게 나타났다. 지역별로는 영주 78.4%, 영월 77.5%순으로 높게 나타났으며, 직경별로는 소경목 90.4%, 중경목 71.7%, 대경목 56.1%로 나타났다. 형상비는 밀도가 높아질수록 수간의 직경에 대한 수고의 비율(형상비)이 높아지며, 70% 이하면 안정성이 높으나 80%를 초과하면 풍해 및 폭설피해로 위험해지기 때문에 일부 지역에서는 임분 밀도관리가 필요하다. 일본잎갈나무의 전체 평균 형상비는 90.6%이며, 지역별로는 평창 108.5%, 영주 105.4%, 단양 100.5% 순으로 나타났다. 경급별로는 소경목 104.9%, 중경목 92.7%, 대경목 73.4%로 전체적으로 일본잎갈나무의 형상비가 80% 이상으로 풍해 및 폭설피해의 위험에 노출되어 있어 빠른 시일 내에 적정 임분 밀도의 관리의 시업이 요구되어 진다.

유한요소 해석을 이용한 현장 콘크리트 부착강도 측정조건 (Measurement Conditions of Concrete Pull-off Test in Field from Finite Element Analysis)

  • 김성환;정원경;권혁;김현오;이봉학
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.185-192
    • /
    • 2002
  • The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesive and strength measurement method ignores the effect of stress concentration from shape of specimens. Therefore, this research calculates stress concentration coefficient as the ratio of drilling depth to drilling diameter($h_s/D$), the ratio of overlay thickness to drilling diameter($h_0/D$), the ratio of steel disk thickness to drilling diameter(t/D), the ratio of overlay elastic modulus to substrate modulus($E_1/E_0$), the distance from core to corner border(L_$_{corner}$) and the distance between cores(L_$_{coic}$) vary. The finite element method is adapted to analysis The results from 'the F.E.M analysis are as follows. The stress concentration effects can be minimized when the ratio of drilling depth to drilling diameter($h_s/D$) is 0.20~0.25, the elastic modulus ratio($E_1/E_0$) is 06~1.0, and the ratio of steel disk thickness to drilling diameter(t/D) is 3.0. The overlay thickness, the distance from specimens to corner border(L_$_{corner}$), the distance between cores(L_$_{coic}$) almost do not affect to the stress concentration.

  • PDF

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

An analytical investigation of soil disturbance due to sampling penetration

  • Diao, Hongguo;Wu, Yuedong;Liu, Jian;Luo, Ruping
    • Geomechanics and Engineering
    • /
    • 제9권6호
    • /
    • pp.743-755
    • /
    • 2015
  • It is well known that the quality of sample significantly determines the accuracy of soil parameters for laboratory testing. Although sampling disturbance has been studied over the last few decades, the theoretical investigation of soil disturbance due to sampling penetration has been rarely reported. In this paper, an analytical solution for estimating the soil disturbance due to sampling penetration was presented using cavity expansion method. Analytical results in several cases reveal that the soil at different location along the sample centerline experiences distinct phases of strain during the process of sampling penetration. The magnitude of induced strain is dependent on the position of the soil element within the sampler and the sampler geometry expressed as diameter-thickness ratio D/t and length-diameter ratio L/D. Effects of sampler features on soil disturbance were also studied. It is found that the induced maximum strain decreases exponentially with increasing diameter-thickness ratio, indicating that the sampling disturbance will reduce with increasing diameter or decreasing wall thickness of sampler. It is also found that a large length-diameter ratio does not necessarily reduce the disturbance. An optimal length-diameter ratio is suggested for the further design of improved sampler in this study.