• 제목/요약/키워드: Diameter of water drop

검색결과 122건 처리시간 0.025초

세관내 액단상의 열전달과 압력강하에 관한 연구 (The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes)

  • 김세웅;홍진우;손창효;노건상;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;김봉구
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;이강희;김봉구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.782-787
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change or the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural Integrity of the material capsule called 04M-l7U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19 6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's In-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

  • PDF

헬리컬 코일관 내 초임계 $CO_2$의 압력강하 특성 (Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;노건상;구학근;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.216-221
    • /
    • 2005
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a helically coiled tube were investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a double pipe type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. It was made of a copper tube with the inner diameter of 4.85 [mm], the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were 200${\sim}$600 [kg/$m^2$s] and the average pressure varied from 7.5 [MPa] to 10.0 [MPa]. The main results were summarized as follows: The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

액체 로켓용 충돌형 Triplet 인젝터의 미립화 특성에 관한 연구 (A study on spray characteristics of the triplet impinging stream type injector for liquid rocket)

  • 박성영;김선진;박승운;김유
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1005-1014
    • /
    • 1996
  • An experimental investigation has been carried out to examine the influence of injector design variables and operating conditions on the resultant drop size for triplet impinging streams injectors. The variables studied in this investigation are pressure drop, impinging angle, orifice length to diameter ratio, and impinging point distance. Droplet-size data are obtained using water as the propellant simulant by Malvern Particle Analyzer System. Drop size decreases with increasing impinging angle and pressure drop while other injector parameters remain constant at the same point. But it is found that there is no noticeable droplet-size change which results from change in orifice length to diameter ratio or impinging point distance within the investigated range.

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

Rheology and pipeline transportation of dense fly ash-water slurry

  • Usui, Hiromoto;Li, Lei;Suzuki, Hiroshi
    • Korea-Australia Rheology Journal
    • /
    • 제13권1호
    • /
    • pp.47-54
    • /
    • 2001
  • Prediction of the maximum packing volume fraction with non-spherical particles has been one of the important problems in powder technology. The sphericity of fly ash particles depending on the particle diameter was measured by means of a CCD image processing instrument. An algorithm to predict the maximum packing volume fraction with non-spherical particles is proposed. The maximum packing volume fraction is used to predict the slurry viscosity under well dispersed conditions. For this purpose, Simha's cell model is applied for concentrated slurry with wide particle size distribution. Also, Usui's model developed for aggregative slurries is applied to predict the non-Newtonian viscosity of dense fly ash - water slurry. It is certified that the maximum packing volume fraction for non-spherical particles can be successfully used to predict slurry viscosity. The pressure drop in a pipe flow is predicted by using the non-Newtonian viscosity of dense fly ash-water slurry obtained by the present model. The predicted relationship between pressure drop and flow rate results in a good agreement with the experimented data obtained for a test rig with 50 mm inner diameter tube. Base on the design procedure proposed in this study, a feasibility study of fly ash hydraulic transportation system from a coal-fired power station to a controlled deposit site is carried out to give a future prospect of inexpensive fly ash transportation technology.

  • PDF

충돌분류에 의한 액적의 크기 및 속도특성에 관한 실험적 연구 (An Experimental study on the drop size and velocity characteristic of drop by impinging jets)

  • 한재섭;김선진
    • 한국분무공학회지
    • /
    • 제4권4호
    • /
    • pp.30-37
    • /
    • 1999
  • The breakup characteristics of liquid sheet formed by the liquid rocket injector has a close relation with the combustion efficiency. In this paper, basic characteristics of droplet size and velocity distribution were measured with PDPA for the Like Doublet Impinging Injector. Test variables were the angle of impact, the diameter of orifice and jet velocity. Water was used as test fluid. As a result, for impingement angle less than 90 degree, following correlations were obtained between drop size and design parameters : $D_{32}({\mu}m)=295.0{\times}V^{-0.09}\times(2\theta)^{-0.1}{\times}d^{0.072}$. For impingement angle greater than 100 degree, drop sizes were increased but eventually converged to a certain limiting value.

  • PDF

루프 히트파이프의 작동에 영향을 미치는 인자에 대한 이론적 분석 (A Theoretical Analysis on the Factors Affecting the Operation of Loop Heat Pipe)

  • 이기우;전원표;이욱현;박기호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1107-1116
    • /
    • 2004
  • In this paper, the effects of diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.