• 제목/요약/키워드: Diameter Ratio

검색결과 3,095건 처리시간 0.039초

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

2벽면 확대 사각채널에서 리브 피치가 열전달과 마찰계수에 미치는 효과 (Effect of Rib Pitch on Heat Transfer and Friction Factor in a Two Wall Divergent Channel)

  • 안수환;이명성;정성수;배성택
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.175-180
    • /
    • 2014
  • Experimental investigations of the heat transfer and friction factors in the ribbed divergent rectangular channel with the channel exit hydraulic diameter to inlet hydraulic diameter ratio of 1.16 were performed. The surface heaters were mounted onto the two opposite walls. The main experimental parameter is the ratio of rib pitch (p) to height (e), at which the ratios (p/e) of 6, 10, and 14 are considered in the channel with ribs on one wall only. The straight ribbed square channel is also considered as a comparison. The major findings are that the ratio of p/e = 6 shows the highest values in the heat transfer and the ratio of p/e = 10 indicates the greatest friction factor in the ribbed divergent channel. Editor's note:No major changes or corrections needed. Well written.

Pull-Out Behaviour of Hooked End Steel Fibres Embedded in Ultra-high Performance Mortar with Various W/B Ratios

  • Abdallah, Sadoon;Fan, Mizi;Zhou, Xiangming
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.301-313
    • /
    • 2017
  • This paper presents the fibre-matrix interfacial properties of hooked end steel fibres embedded in ultra-high performance mortars with various water/binder (W/B) ratios. The principle objective was to improve bond behaviour in terms of bond strength by reducing the (W/B) ratio to a minimum. Results show that a decrease in W/B ratio has a significant effect on the bond-slip behaviour of both types of 3D fibres, especially when the W/B ratio was reduced from 0.25 to 0.15. Furthermore, the optimization in maximizing pullout load and total pullout work is found to be more prominent for the 3D fibres with a larger diameter than for fibres with a smaller diameter. On the contrary, increasing the embedded length of the 3D fibres did not result in an improvement on the maximum pullout load, but increase in the total pullout work.

참여기체를 가진 무한 원형관 계의 복사 열전달 증진 (Augmentation of Radiative Heat Transfer in an Infinite Cylindrical Pipe Enclosing a Participating Gas)

  • 변기홍
    • 대한기계학회논문집
    • /
    • 제16권10호
    • /
    • pp.1955-1962
    • /
    • 1992
  • 본 연구에서는 무한 원형관 안의 복사에 참여하는 참여가스에 면을 도입시키 면, 참여가스로부터 원형관 벽면으로의 복사 열유속(radiatve heat flux)이 증진 또는 감소되는 현상을 연구하는 데 있다. 참여가스는 흡수, 방사 특성이 온도와 파장에 변하지 않는 회체가스(gray gas)이거나, 화석 연료 연소시 연소가스의 성분이며, 복사 에 참여하는, 수증기와 이산화탄소의 혼합물이다. 편의상, 이 가스를 실제가스(real gas)라 부르기로 한다.도입면은 동축 무한 원형관(coaxial Infinite cylinder)이다. 참여가스의 성분, 계의 직경, 동축 무한 원형관 사이의 직경비, 면의 방사율, 면과 가 스의 온도가 열전달 증진에 미치는 영향을 연구하고자 한다.

신생아 모발 표면을 둘러싸고 있는 비늘에 관한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of Scales Surrounding the Surface of Newborn Hair)

  • 정희중;진현숙;장아영;장은주;장병수;김경숙
    • 융합정보논문지
    • /
    • 제10권5호
    • /
    • pp.216-223
    • /
    • 2020
  • 본 연구는 신생아 두피 모발의 기저부에서부터 말단부위까지의 외부형태와 모발 가로 직경 대비 모발 표면에 노출된 비늘의 장축 직경 비율을 주사전자현미경으로 관찰하였다. 신생아 모발은 두피에 인접한 부위에서 부터 모발의 끝부분으로 갈수록 완만하게 가늘어지는 것을 확인하였다. 본 연구에서 모발의 두께가 커질수록 노출된 비늘의 장축 직경 비율은 상대적으로 작아지는 것으로 확인되었지만 모발 표면의 노출된 비늘 장축 직경은 모발의 굵기에 관계없이 비슷한 길이로 나타났다. 결론적으로 가는 모발이나 굵은 모발 표면에 노출된 비늘의 장축 직경은 크게 변화하지 않는 것을 확인하였다.

미소초점엑스선원 개발을 위한 전산모사 (Computer Simulation for Development of Micro-Focus X-ray Generator)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.403-408
    • /
    • 2011
  • MFX tube를 개발하기 위하여, MFX tube 내에서 전계방출음극으로부터 방출된 전자의 궤적을 SIMION 프로그램을 이용하여 전산모사하였다. 전자의 출발위치와 상관없이 emitter에서 방출된 전자빔을 한곳에 집중시킬 수 있는 optimum extractor voltage Ve가 존재한다는 것을 알아내었다. Extractor voltage Ve는 source voltage Vs에 따라 변하지만, 두 전압의 비율(Ve/Vs)는 항상 일정하고, 그 값은 99.4%였다. Source와 extractor에 인가된 전압의 비율(Ve/Vs)이 99.4%일 때, 교차점에서의 빔 직경은 $1.2{\mu}m$였다. MFXG의 초점 크기는 교차점에서의 beam diameter보다 작을 수 없기 때문에, 교차점에서의 beam diameter을 작게 할 수 있는 조건을 찾는 것은 중요하다. 따라서 위의 두 결과는 MFX tube의 개발에 있어서 매우 중요한 결과로 판단된다.

True Posterior Communicating Artery Aneurysms with High Risk of Rupture despite Very Small Diameter

  • Shin, Dong Gyu;Park, Jaechan;Kim, Myungsoo;Kim, Byoung-Joon;Shin, Im Hee
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권2호
    • /
    • pp.215-223
    • /
    • 2022
  • Objective : This retrospective study investigated the clinical and angiographic characteristics of ruptured true posterior communicating artery (PCoA) aneurysms in comparison with junctional PCoA aneurysms presenting with a subarachnoid hemorrhage. Methods : The medical records and radiological data of 93 consecutive patients who underwent three-dimensional rotational angiography and surgical or endovascular treatment for a ruptured junctional or true PCoA aneurysm over an 8-year period were examined. Results : The maximum diameter of the ruptured true PCoA aneurysm (n=13, 14.0%) was significantly smaller than that of the ruptured junctional PCoA aneurysms (n=80, 4.45±1.44 vs. 7.68±3.36 mm, p=0.001). In particular, the incidence of very small aneurysms <4 mm was 46.2% (six of 13 patients) in the ruptured true PCoA aneurysm group, yet only 2.5% (two of 80 patients) in the ruptured junctional PCoA aneurysm group. Meanwhile, the diameter of the PCoA was significantly larger in the true PCoA aneurysm group than that in the junctional PCoA aneurysm group (1.90±0.57 vs. 1.15±0.49 mm, p<0.001). In addition, the ipsilateral PCoA/P1 ratio was significantly larger in the true PCoA aneurysm group than that in the group of a junctional PCoA aneurysm (mean PCoA/P1 ratio±standard deviation, 2.67±1.22 vs. 1.14±0.88; p<0.001). No between-group difference was identified for the modified Fisher grade, clinical grade at admission, and 3-month modified Rankin Scale score. Conclusion : A true PCoA aneurysm was found to be associated with a larger PCoA and ruptured at a smaller diameter than a junctional PCoA aneurysm. In particular, the incidence of a ruptured aneurysm with a very small diameter <4 mm was significantly higher among the patients with a true PCoA aneurysm.

A simple test method to assess slump flow and stability of self-compacting concrete

  • Bouziani, Tayeb
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.111-116
    • /
    • 2018
  • Establishment of test methods to assess the fresh properties of self-compacting concrete (SCC) are required to ensure the homogeneity in fresh and hardened states. This paper discusses the suitability of a simple test method for assessing the slump flow and stability of SCC by testing on self-compacting mortar (SCM) fraction. The proposed test method aims at investigating slump flow diameter test and sieve stability test of SCC by testing SCM fraction with a plunger penetration apparatus. A central composite modeling design was performed to evaluate the effects of water/cement ratio (W/C), superplasticizer dosage (SP) and powder marble content (MP) on slump flow diameter, stability and plunger penetration test of fresh SCC. The responses of the derived statistical models are slump flow (Sf), sieve stability (S) and plunger penetration (P). Relationships obtained in this study show acceptable correlations between plunger penetration test value and slump flow diameter test results and stability. It should note that the developed relationships are very useful to predict slump flow diameter and stability of studied SCC mixtures by carrying out a simple plunger penetration test on its mortar, which can save labour and time in laboratory experiments.

태양열 온수 저장조의 성층 온수 추출에 관한 연구 (Thermally Stratified Hot Water Extraction)

  • 박이동;정운철;성상우
    • 태양에너지
    • /
    • 제11권2호
    • /
    • pp.34-40
    • /
    • 1991
  • Thermal stratification enhancement for the higher extraction efficiency of hot water storage tank was experimentally studied with transparent fiber glass cylindical tank($350{\ell}$, D=516mm, H=1680mm). Height to diameter ratio (H/D =1,2,3), flow rate(Q= 8,10,12LPM), inlet-outlet temperature differences(${\Delta}T=20,25,30^{\circ}C$), and geometry of inlet-outlet port were the parameters. In particular, three kind of distributors were used for geometry of inlet-outlet port. As a result, it was possible to get extraction efficiency of 95% by using the distributor having variable diameter but keeping a constant diameter of perforation. So it is recommendable to design the distributor so that the main pipe decrease in diameter toward the dead end.

  • PDF

다패스 열교환기에서의 유량분배 특성 (Flow Distribution Characteristics in a Multi-Pass Heat Exchanger)

  • 김민수;강수진;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.737-742
    • /
    • 2006
  • This paper numerically investigates to evaluate the performance according to the number of passes and the inlet/outlet diameter in a multi-pass multi-branch heat exchanger. A JF factor is used as an evaluation characteristic value to consider the heat transfer rate and the pressure drop simultaneously. It estimates the performance according to the number of passes and the inlet diameter of the reference heat exchanger. When the ratio of the inlet diameter to the header height is about 0.5, the optimum number of passes is selected along with the inlet diameter.

  • PDF