• Title/Summary/Keyword: Diameter Ratio

Search Result 3,088, Processing Time 0.031 seconds

Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trial

  • Heba Ezzeldin Khorshid;Noha Ossama Issa;Amr Mohamed Ekram
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.101-113
    • /
    • 2023
  • PURPOSE. This randomized controlled trial aimed to evaluate the effect of implants' two different diameters and cantilever lengths on the marginal bone loss and stability of mplants supporting maxillary prostheses. MATERIALS AND METHODS. Ninety-six implants were placed in sixteen completely edentulous maxillary ridges. Patients were randomly divided into two groups: Group A, implants were placed with a cantilever to anterior-posterior AP spread length (CL:AP) at a ratio of 1:3; Group B, implants were placed with a CL:AP at a ratio of 1:2. Patients were further divided into four sub-groups: Groups A1, A2, B1, and B2. Groups A1 and B1 received small diameter implants while Groups A2 and B2 received standard diameter implants. Bone height and stability measurements around each implant were performed at 0, 4, 8 and 24 months after definitive prostheses delivery. RESULTS. Statistical analysis of the mean implant stability and height values revealed an insignificant difference between Group A1 and Group A2 at all the different time intervals while significantly higher values in Group B1 in comparison with Group B2. Results also showed significantly higher values in Group A1 in comparison with Group B1 and an insignificant difference between Group A2 and Group B2 at all the different time intervals. CONCLUSION. It can be concluded that the use of small diameter implants placed with a CL:AP at a ratio of 1:3 provided predictable results and that the 1:2 CL:AP significantly induced more critical bone loss in the small diameter implants group, which can significantly reduce long term success and survival of implants

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION ACCORDING TO THE THREAD DESIGNS AND THE MARGINAL BONE LOSS OF THE IMPLANTS (임프란트 나사형태와 치조골 흡수에 따른 응력분산의 3차원 유한요소법적 분석)

  • Kim, Il-Kyu;Son, Choong-Yul;Jang, Keum-Soo;Cho, Hyun-Young;Baek, Min-Kyu;Park, Sheung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.60-71
    • /
    • 2008
  • The objective of this study is to evaluate the stress distribution according to the thread design and the marginal bone loss of a single unit dental implant under the axial and offset-axial loading by three dimensional finite element analysis. The implants used had the diameter of 5mm and 4mm with 13mm in length and prosthesis with a conical type which is 6mm in height and 12mm in diameter. The thread designs were triangular, square and buttress. In the three dimensional finite element model with $15\times15\times20mm$ hexahedron and 2mm cortical thickness, implants were placed with crown to root ratio 7:12, 10:9, 13:6 and 16:3. And additionally the axial force of 100N were applied into 0mm, 2mm and 4mm away from the center of the implants. The results were as follows 1. The maximum von-Mises stress in cortical bone was concentrated to cervical area of implant, and in cancellous bone, apical portion. 2. Comparing the von-Mises stresses in cortical bone of 2mm and 4mm offset loading with central axial loading, it were increased to 3 and 5 times in diameter 4mm implant, and 2 and 4 times, in diameter 5mm implant. 3. The square threads were more effective than the triangular and butress as the longer diameter, the offset loading, and the worse crown to root ratio. 4. The von-Mises stresses were relatively stable until crown to root ratio 13:6, but it was suddenly increased at 16:3. From the results of this study, minimum requirement of crown to root ratio of implant is 2:1, and in the respect of crown to root ratio, diameter and offset loading, square threads are more effective than triangular and buttress threads.

Initial assessment of hemorrhagic shock by trauma computed tomography measurement of the inferior vena cava in blunt trauma patients

  • Lee, Gun Ho;Choi, Jeong Woo
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.181-188
    • /
    • 2022
  • Purpose: Inferior vena cava (IVC) collapse is related to hypovolemia. Sonography has been used to measure the IVC diameter, but there is variation depending on the skill of the operator and it is difficult to obtain accurate measurements in patients who have a large amount of intestinal gas or are obese. As a modality to obtain accurate measurements, we measured the diameters of the IVC and aorta on trauma computed tomography scans and investigated the correlation between the IVC to aorta ratio and the shock index in blunt trauma patients. Methods: We retrospectively analyzed the medical records of 588 trauma patients who were transferred to the regional trauma center (level 1) of Wonkang University Hospital from March 2020 to February 2021. We included trauma patients 18 years or older who met the trauma activation criteria and underwent trauma computed tomography scans with intravenous contrast within 40 minutes of admission. The shock index was calculated from vital signs before trauma computed tomography scan, and measurements of the anteroposterior diameter of the IVC (AP), the transverse diameter of the IVC (T), and aorta were made 10 mm above the right renal vein in the venous phase. Results: Overall, 271 patients were included in this study, of whom 150 had a shock index ≤0.7 and 121 had a shock index >0.7. The T to AP ratio and AP to aorta ratio were significantly different between groups. Cutoffs were identified for the T to AP ratio and AP to aorta ratio (2.37 and 0.62, respectively) that produced clinically useful sensitivity and specificity for predicting a shock index >0.7, demonstrating moderate accuracy (T to AP ratio: area under the curve, 0.71; sensitivity, 59%; specificity, 87% and AP to aorta ratio: area under the curve, 0.70; sensitivity, 55%; specificity, 91%). Conclusions: The T to AP ratio and AP to aorta ratio are useful for predicting hemorrhagic shock in trauma patients.

NUMERICAL STUDY OF TURBINE BLADE COOLING TECHNIQUES (터빈 블레이드 냉각시스템에 관한 수치해석적 연구)

  • Kim, K.Y.;Lee, K.D.;Moon, M.A.;Heo, M.W.;Kim, H.M.;Kim, J.H.;Husain, A.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.530-533
    • /
    • 2010
  • This paper presents numerical analysis and design optimization of various turbine blade cooling techniques with three-dimensional Reynolds-averaged Navier-Stokes(RANS) analysis. The fluid flow and heat transfer have been performed using ANSYS-CFX 11.0. A fan-shaped hole for film-cooling has been carried out to improve film-cooling effectiveness with the radial basis neural network method. The injection angle of hole, lateral expansion angle of hole and ratio of length-to-diameter of the hole are chosen as design variables and spatially averaged film-cooling effectiveness is considered as an objective function which is to be maximized. The impingement jet cooling has been performed to investigate heat transfer characteristic with geometry variables. Distance between jet nozzle exit and impingement plate, inclination of nozzle and aspect ratio of nozzle hole are considered as geometry variables. The area averaged Nusselt number is evaluated each geometry variables. A rotating rectangular channel with staggered array pin-fins has been investigated to increase heat transfer performance ad to decrease friction loss using KRG modeling. Two non-dimensional variables, the ratio of the eight diameter of the pin-fins and ratio of the spacing between the pin-fins to diameter of the pin-fins selected as design variables. A rotating rectangular channel with staggered dimples on opposite walls are formulated numerically to enhance heat transfer performance. The ratio of the dimple depth and dimple diameter are selected as geometry variables.

  • PDF

Design Optimization and Numerical Study of O-ring using Taguchi Method (다구찌법을 이용한 O-링의 최적설계 및 수치적 연구)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.20 no.5
    • /
    • pp.259-265
    • /
    • 2004
  • The sealing performance of O-rings is affected by working conditions such as applied pressure, operation temperature, pre-compressed ratio and material properties. In this paper, a pressurized and compressed elastomeric bi-polymer O-ring in which is inserted into a rectangular groove is analyzed by non-linear MARC finite element program based on the Taguchi experimental method. O-rings with 9 different profile models are analyzed for design parameters that are related to the diameter ratio between outer diameter and inner one of bi-polymer O-ring, compressive ratio, groove angle and groove depth. The calculated FEM results showed that the affection ratio of design parameter dlD, which may control sealing pressure of O-rings, is the most influential parameter among the groove angle, groove depth and compression ratio.

Robust Design for Shape Parameters of High Pressure Thermal Vapor Compressor by Numerical Analysis (전산해석을 통한 고압열증기압축기 형상변수에 관한 강건 설계)

  • Park, Il-Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.931-937
    • /
    • 2008
  • A high motive pressure thermal vapor compressor(TVC) for a commercial multi-effect desalination(MED) plant is designed to have a high entraining performance and its robustness is also considered in the respect of operating stability at the abrupt change of the operating pressures like the motive and suction steam pressure which can be easily fluctuated by the external disturbance. The TVC having a good entraining performance of more than entrainment ratio 6.0 is designed through the iterative CFD analysis for the various primary nozzle diameter, mixing tube diameter and mixing tube length. And then for a couple of TVC having a similar entrainment ratio, the changes of the entrainment ratio are checked along the motive and suction pressure change. The system stability is diagnosed through the analyzing the changing pattern of the entrainment ratio.

Study on High Performance and Compact Absorber Using Small Diameter Heat Exchanger Tube

  • Yoon Jung-In;Phan Thanh Tong;Moon Choon-Geun;Kim Eun-Pil;Kim Jae-Dol;Kang Ki-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.463-473
    • /
    • 2006
  • The effect of tube diameter on heat and mass transfer characteristics of absorber in absorption chiller/heater using LiBr solution as a working fluid has been investigated by both of numerical and experimental study to develop a high performance and compact absorber. The diameter of the heat exchanger tube inside absorber was changed from 15.88mm to 12.70mm and 9.52mm. In numerical study a model of vapor pressure drop inside tube absorber based on a commercial 20RT absorption chiller/heater was performed. The effect of tube diameter, longitudinal pitch, vapor Reynolds number, longitudinal pitch to diameter ratio on vapor pressure drop across the heat exchanger tube banks inside absorber have been investigated and found that vapor pressure drop decreases as tube diameter increases, longitudinal pitch increases, vapor Reynolds number decreases and longitudinal pitch to diameter ratio increases. In experimental study, a system includes a tube absorber, a generator, solution distribution system and cooling water system was set up. The experimental results shown that the overall heat transfer coefficient, mass transfer coefficient. Nusselt number and Sherwood number increase as solution flow rate increases. In both of study cases, the heat and mass transfer performance increases as tube diameter decreases. Among three different tube diameters the smallest tube diameter 9.52mm has highest heat and mass transfer performance.

Behaviors of Mach Disk in Underexpanded Supersonic Moist Jet (초음속 습공기 제트에서 발생하는 마하디스크의 거동)

  • 백승철;김희동;권순범
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.87-90
    • /
    • 2003
  • It has been well known that the major feature of compressible flow fields might be different depending on their formation processes. The objectives of the present study is to investigates the effect of jet development on the time history of supersonic jet flow field, accompanying nonequilibrium condensation. Especially, the behaviors of Mach disk diameter and location in a supersonic moist air jet are presented in terms of nozzle pressure ratio and initial relative humidity. The relative humidity of moist air is controlled at the nozzle supply, and the nozzle pressure ratio is varied to obtain the moderately underexpanded flows at the exit of the nozzle, installed in an indraft wind tunnel. It is found that at the same pressure ratio the Mach disk diameter increases with the initial relative humidity, while moves further upstream. Furthermore, the values of Mach disk diameter and location for increasing pressure ratio show larger than those for increasing.

  • PDF

Comparative Anatomy of Diffuse-Porous Woods Grown in Korea(II) -Characteristics by Habit and Phenology- (한국산(韓國産) 산공재(散孔材)의 해부학적(解剖學的) 특성(特性)에 관한 비교연구(比較硏究)(II) -Habit과 Phenology에 따른 특성(特性)-)

  • Chung, Youn-Jib;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 1996
  • The frequency distribution diagrams of Korean diffuse-porous woods, 36 families, 75 genera, 145 species, 215 specimens in relation to habit and phenology were analyzed. As the habit character changes from shrub to tree, such quantitative features as vessel frequency, percentage of solitary vessels, length/diameter(L/D) ratio of vessel element decreased but tangential vessel diameter, fiber length/vessel element length(F/V) ratio increased. Qualitative features such as helical vessel wall thickening, diffuse distribution of longitudinal parenchyma, heterogeneous ray composition decreased, while alternate intervessel pits, libriform wood fiber, simple perforations increase. As the phenology character changes from evergreen to deciduous species, such quantitative features as percentage of solitary vessels, vessel element length and L/D ratio decreased but tangential vessel diameter, F/V ratio increased. Diffuse distribution of longitudinal parenchyma, heterogeneous ray composition, and crystals in qualitative features decreased, while alternate intervessel pits, libriform wood fiber, simple perforation of vessel element, ray width and ray height increased.

  • PDF

A Stydy on Steel Wire Fiber Reinforced Refractory Castable (철근 캐스터블 내화물의 고온특성에 관한 연구)

  • 박금철;최영섭;한문희;장영재;박근원
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.2
    • /
    • pp.69-74
    • /
    • 1980
  • This study deals with the wire content, wire diameter, aspect ratio , it's arrangement of steel, wire fiber and the sorts of castable which affected the character of steel wire fiber reinformced refractory castable. Two kinds of alumina based refractory castables, one is for 1650℃ and the other is for 1800℃, and stainless steel which is SUS 304 type 0.25, 0.34 , 0.37 and 0.50m/min diameter were used respectively. Aspect ratio was adjusted to 50, 75, 100 and steel fiber content was also adjusted to 1-4wt% each. The results of the experiment were as follows : 1. At firing temperature around 1,000℃, MOR is increased with increasing wire content and aspect ratio with decreasing firing temperature, which depends on the Romualdi's Fiber Spacing Theory. But for calculation of the fiber spacing, Swamy equation is more a aplicable to the extensive fiber mixing conditions. However, the condition differs from the above at firing temperature around 1,350℃ ,because of the degradation of wire and the progress of sintering of castable. 2. Linear change is getting larger corresponding to the increase of wire content, and the spaling resistivity is increasing corresponding to the increase of wire content and to aspect ratio, and with decreasing wire diameter. 3. Firing shrinkage under load is getting greater as higher wire content, and the shrinkage of the test pieces which fiber is vertically oriented is getting greater than the test pieces which fiber is randomly oriented.

  • PDF