• Title/Summary/Keyword: Dialysis water

Search Result 115, Processing Time 0.027 seconds

Effects of Hot Water Treatment and Dialysis on Measuring the Average Molecular Weight of Alginates (열수처리와 투석이 alginates의 평균분자량의 측정에 미치는 영향)

  • YOU Byeong Jin;LIM Yeong Seon;RYU Hong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In preparing sodium alginates from sea tangle (Laminaria japonica) powder using the Mexican process, alkaline extraction, conversion to alginic acid and reversion to sodium alginates were used to increase purity. The effect of hot water treatment and dialysis on measuring the average molecular weight of sodium alginates were investigated. Intrinsic viscosity and average molecular weight of sodium alginates after dialysis were higher than those before dialysis. Average molecular weight of sodium alginates treated with hot water was higher than that without. Hot treatment has little effect on the ash content of sodium alginates. Ash content of sodium alginates before dialysis were $27-30\%$ those after dialysis were $10\%.$ After dialysis, Na content was highest $(89-91\%),$ K was $11-12\%,$ Ca was $1.9\%,$ and Mg was $0.05\%.$ Ash content of alginates had little effect on average molecular weight. SAV (slope of apparent viscosity) of alginates solution after dialysis showed higher values than before. SAV of the alginates with hot water treatment were higher than without treatment.

Development of a Unit Module for the Process of Large Scale Dialysis for Silk fibroin (실크 피브로인의 대규모 투석 공정의 단위 모듈의 개발)

  • Kim, Dong-Woo;Ha, Sung-Jin;Lim, Gun-Bin;Hur, Won
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.27-30
    • /
    • 2001
  • For the development of a large-scale dialysis process for silk fibroin solution, a batch and continuous dialysis chamber was designed and built, which are to be used as a unit module for the process. A series of dialysis experiments were carried out to estimate the kinetic parameters for dialysis using the solutions of salt-solubilized silk fibroin. The solution was dialyzed by distilled water either batch-wise or continuously. Dialysis kinetics was monitored by measuring refractometery at high salt concentration and conductivity at lower salt concentration. The apparent dialysis coefficients were $5.4g/m^2-hr$ and $1.8g/m^2-hr$, for well mixed batch and continuous dialysis, respectively. The alteration of molecular weight distribution of dialyzed silk fibroin solution was monitored.

  • PDF

Body Impedance Measurements for edematous patients (부종환자에서 임피던스를 이용한 수분변화의 예측)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.973-976
    • /
    • 1995
  • The assessment method of human body composion by bioelectrical impedance is very simple, safe, rapid and noninvasive. Based on prediction formulas for total body water from bioelectrical impedance, the observed weight loss should be associated with an increase in impedance. However in edematous patients for dialysis, the calculated total body water loss as calculated from impedance were overestimated and significantly higher than the weight loss after dialysis. So determination of impedance were made in 50 edematous patients before, during and after dialysis. Mean weight loss, which was assumed to be only loss of water was 1719$\pm$ 866 gr and mean impedance change was 71.0 $\pm$ 23.0 Ohm under 50kHz. Body weight loss was highly correlated [r>0.81 with the increase in body impedance under variable frequencies[1, 10, 20, 30, 40, 50 kHz . But there were no differences between frequences. In conclusion, clinical application of bioelectrical impedance method is useful for individual edematous patients with new correlation equation[Y=230+26.8X, X;Impedance change, Y;Calculated total body water loss .

  • PDF

Dialysis in parallel-flow rectangular membrane modules with external reflux for improved performance

  • Yeh, Ho-Ming;Cheng, Tung-Wen;Chen, Kuan-Hung
    • Membrane and Water Treatment
    • /
    • v.1 no.2
    • /
    • pp.159-169
    • /
    • 2010
  • The effect of external recycle on the performance of dialysis in countercurrent-flow rectangular membrane modules was investigated both theoretically and experimentally. Theoretical analysis of mass transfer in parallel-flow device with and without recycle is analogous to heat transfer in parallel-flow heat exchangers. Experiments were carried out with the use of a microporous membrane to dialyze urea aqueous solution by pure water. In contrast to a device with recycle, improvement in mass transfer is achievable if parallel-flow dialysis is operated in a device of same size with recycle which provides the increase of fluid velocity, resulting in reduction of mass-transfer resistance, especially for rather low feed volume rate.

Isolation of Humic Acid from Water (물 중의 Humic Acid 분리)

  • Yook, Keun-Sung;Kim, Yong-Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.118-121
    • /
    • 1996
  • 56.2% of Aldrich HA was recovered from water by XAD-8 and AGMP-50 procedure. With this method, 0.58mg/l of HA was determined in the water collected from irrigation reservoir near Tae Dok Science Town. For the removal of ash from Aldrich HA, centrifugation was simple, but as effective as dialysis. Neither centrifugation nor dialysis removed Na at all. Only with XAD-8 and AGMP-50 procedure, Na and ash were completely removed.

  • PDF

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

A Case of Peritoneal Dialysis-related Peritonitis Caused by Aeromonas Hydrophila in the Patient Receiving Automated Peritoneal Dialysis

  • Kim, Hyun Jin;Park, Hyun Sun;Bae, Eunsin;Kim, Hae Won;Kim, Beom;Moon, Kyoung Hyoub;Lee, Dong-Young
    • Electrolytes & blood pressure
    • /
    • v.16 no.2
    • /
    • pp.27-29
    • /
    • 2018
  • Peritoneal dialysis (PD)-related peritonitis is a major cause of injury and technique failure in patients undergoing PD. Aeromonas hydrophila is ubiquitous in the environment, and is a Gram-negative rod associated with infections in fish and amphibians in most cases; however, it can also cause opportunistic infections in immunocompromised patients. We report a case of A. hydrophila peritonitis in a 56-year-old male on automated PD. Peritonitis may have been caused by contamination of the Set Plus, a component of the automated peritoneal dialysis device. Although Set Plus is disposable, the patient reused the product by cleansing with tap water. He was successfully treated with intraperitoneally-administered ceftazidime and has been well without recurrence for more than 2 years.

실크 피브로언의 투석 속도론

  • Kim, Dong-U;Ha, Seong-Jin;Im, Geon-Bin;Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.265-266
    • /
    • 2001
  • Solubilized silk fibroin by salt can be further processed by dialysis. The solution was dialyzed by continuous distilled water. The dialysis kinetics of silk fibroin was investigated.

  • PDF

In vitro release test models for water-insoluble drugs loaded in colloidal carriers

  • Lee, Jung-Min;Choi, Sung-Up;Lee, Byoung-Moo;Lee, Sung-Jae;Choi, Young-Wook
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.295.1-295.1
    • /
    • 2003
  • A suitable model for the estimation of the drug release from nanoparticles has been varied and problematic, especially for the release from lipid nanoparticles containing water-insoluble drugs, due to the difficult particle collection from the release medium. Dialysis membrane has been widely used for the release test from colloidal carrier systems. The amount of drug from the carriers in normal dialysis diffusion technique was very low typically. (omitted)

  • PDF

Permeability of anion-exchange membrane for Cl- ions. Dialysis of hydrochloride acid in the presence of nickel chloride

  • Palaty, Zdenek;Bendova, Helena
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • Using a conventional two-compartment cell with stirrers the separation of an aqueous solution of HCl-$NiCl_2$ by an anion-exchange membrane Neosepta-AFN was investigated. The dialysis process was characterized by the permeability coefficient of the membrane towards to $Cl^-$ ions. This quantity was determined by the numerical integration of equations, which describe the time dependence of the total concentration of $Cl^-$ ions in compartment initially filled with stripping agent (water), combined with an optimizing procedure. The analysis of the experimental results showed that this permeability coefficient is a satisfactory characteristic for the process studied. It can be graphically correlated with the initial acid and initial salt concentrations in the compartment initially filled with acid+salt mixture.