• 제목/요약/키워드: Dialysis method

검색결과 174건 처리시간 0.023초

Testosterone-encapsulated Surfactant-free Nanoparicles of Poly(DL-lactide-co-glycolide): Preparation and Release Behavior

  • Jeong, Young-Il;Shim, Yong-Ho;Song, Ki-Chan;Park, Youeng-Guen;Ryu, Hwa-Won;Nah, Jae-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1579-1584
    • /
    • 2002
  • Since surfactant or emulsifiers remained on the nanoparticle surface significantly affect the physicochemical properties, the biodegradation rate, the biodistribution, and the biocompatibility of nanoparticles, surfactant-free nanoparticles should be good candidate. surfactant-free PLGA nanoparticles were successfully prepared by both the dialysis method and the solvent diffusion method. The PLGA nanoparticles prepared using the solvent diffusion method has a smaller particle size than the dialysis method. The solvent diffusion method was better for a higher loading efficiency than the dialysis method but the nanoparticle yield was lower. Testosterone (TST) release from the PLGA nanoparticles was dependent on the particle size rather than the drug contents. Testosterone release from the PLGA nanoparticles prepared by the solvent diffusion method using acetone was faster than those prepared by the dialysis method. TST release from the PLGA nanoparticles prepared by the solvent diffusion method using acetone and the dialysis method using dimethylformamide (DMF) was completed for 4 days while the PLGA nanoparticles prepared by the dialysis method using acetone showed approximately 80% TST release after 4 days. Since the PLGA nanoparticle degradation ratio was below 20% within 5 days at all samples while TST release completed within 4 days, TST release was dependent on the diffusion mechanism rather than degradation.

효소-항체의 결합 및 효소면역측정 방법의 연구 (Study on Antibody-enzyme Coupling and Enzyme Immunoassay Methods)

  • 장선일
    • 동의생리병리학회지
    • /
    • 제18권3호
    • /
    • pp.874-879
    • /
    • 2004
  • Alakaline phosphatase (ALP)- or horseradish peroxidase (HRP)-antibody conjugate was used frequently on the immunological detection methods such as enzyme-linked immunosobent assay (ELISA), immunobolt, immunohistochemistry. The classical enzyme-antibody coupling method by one-step (direction) injection of glutaraldehyde bring into being disadvantage such as low sensitivity of antigen detection because of homopolymers. This study was modified with the dialysis glutaraldehyde method to provide simple coupling through E-amino residues present in most protein. The dialysis glutaraldehyde coupling effects were better than the classical one-step glutaraldehyde injection in antigen detection of ELISA and immunobolt. Optimal dose of the dialysis glutaraldehyde solution was 0.10-0.25 %. This results suggest that the dialysis glutaraldehyde coupling method can readily applied to antigen detection of in vitro and in vivo.

透析法에 依한 이온量 및 分子量의 決定에 關한 硏究 (第4報). 比表面積 및 透析膜孔이 透析에 미치는 影響 (A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅳ). Effects of Specific Surface Area and Pore Size of Dialysis Membrane on Dialysis)

  • 신윤경;이전;김태천
    • 대한화학회지
    • /
    • 제21권1호
    • /
    • pp.44-52
    • /
    • 1977
  • 透析係數가 常數로서 나타날 수 있는 條件究明의 一環으로서 透析液 單位體積當의 透析膜面積인 比表面積과 透析膜孔의 크기가 透析에 미치는 영향을 究明하였다. 1回의 透析實驗에서 任意時間區間마다 任意부피의 透析液試料를 잇따라 菜取하는 方法(間歇試料菜取法이라 呼稱하기로 함)은 透析係數를 求하는 方法으로서 採擇할 수 있음과, 또한 透析膜孔이 상당히 크더라도 膜을 通한 擴散係數는 自由擴散係數에 미치지 못함을 밝히었다.

  • PDF

투석과 건조방법이 다시마(Laminaria japonica) 알긴산의 물성에 미치는 영향 (Effects of Dialysis and Various Drying Methods on Physical Properties of Alginates Prepared from Sea Tangle, Laminaria japonica)

  • 임영선;유병진
    • 한국수산과학회지
    • /
    • 제38권4호
    • /
    • pp.226-231
    • /
    • 2005
  • To investigate the physical properties of sea tangle (Laminaria japonica) alginates, extracted by the Mexican process, the effects of extracting time and drying methods on intrinsic viscosities, MWs and DPs of alginates were examined. The MWs of alginates before and after dialysis decreased with increase of extracting time. The MW s before dialysis were lower than those after dialysis. The ash contents before dialysis decreased with increase of extracting time. After dialysis the ash contents of the alginates showed 10.4-10.9% of those, which were little affected by extracting time. In the ash composition after dialysis, the sodium content was 4.4 g/100 g, $90\%$ of total ash content. The ash contents, the intrinsic viscosities, the average molecular weight and the DPs of the alginates dried by AD before dialysis were higher than those by VF. The ash and uronic acid contents of alginates after dialysis showed $10.6-10.9\%\;and\l88.1-88.9\%$, respectively. But the intrinsic viscosities, the MWs and DPs of the alginates after dialysis gradually decreased by following dry methods. The decreased order was ADAD, ADVF, VFAD, VFVF. The coefficient of determination between MWs and DPs in the alginates having more than 300 kDa was 0.999.

The interaction of zipeprol with $\beta$-cyclodextrin

  • Kim, Chong-Kook;Choi, Han-Gon
    • Archives of Pharmacal Research
    • /
    • 제10권2호
    • /
    • pp.69-74
    • /
    • 1987
  • The characteristics of zipeprol-$\beta$-cyclodextrin system were studied by circular dichroism, competitive UV method and dialysis method. In this experiment, binding constants by competitive UV method, circular dichroism and dialysis method were 155 M$^{-1}$ 187 M$\^{-1}$/($\pm$ 5%) and 315 $^{-1}$, repectively. It shows that zipeprol forms 1:1 compelx with $\beta$-cyclodextrin by circular dichroism and 1:2 by dialysis method. pH profile shows that binding force seems to be a hydrophobic interaction. It is suggested that benzene ring be accomodated in the cavity of $\beta$-cyclodextrin.

  • PDF

소아 환자에서 복강경 복막 투석관 삽입술과 개복 삽입술의 비교 (Comparison of the Laparoscopic and Open Peritoneal Dialysis Catheter Insertion in Children)

  • 김현수;정수민;이석구;서정민
    • Advances in pediatric surgery
    • /
    • 제17권2호
    • /
    • pp.125-132
    • /
    • 2011
  • The aim of this study was to compare peritoneal dialysis catheter insertion by the open method to the laparoscopic method. Twenty four laparoscopic and 10 open peritoneal dialysis catheter placements were performed in children between 2001 and 2008. Patient characteristics, operation related data, procedural complications and clinical outcome were compared. Although there were no cases of catheter obstruction, exit site infection or bleeding in the laparoscopic group, compared to the open method, there was no statistically significant difference between the two groups. Catheter removal rate due to complication was high in the open group and catheter survival rate was high in the laparoscopic group. We concluded that laparoscopic peritoneal dialysis catheter placement is feasible in children of all age groups with at least equivalent functional results compared to the open method. An advantage of laparoscopic catheter insertion is removal of the great omentum and easy fixation of the catheter to the abdominal wall.

  • PDF

透析法에 依한 이온量 및 分子量의 決定에 關한 硏究 (第二報). 攪拌이 透析에 미치는 影響 (A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (II). Effect of the Agitation on Dialysis)

  • 신윤경;이전
    • 대한화학회지
    • /
    • 제17권3호
    • /
    • pp.213-223
    • /
    • 1973
  • 透析液 및 溶媒液의 攪拌이 透膜面에 미치는 流體力學的인 壓力分布狀態를 究明하였고, 攪拌으로 招來되는 透膜面兩面의 壓力不均衡을 除去할 目的으로 攪拌裝置의 開發을 試圖하였다. 다음 攪拌速度가 透析係數에 미치는 影響을 究明하여 가장 正確한 透析係數를 求할 수 있는 攪拌速度를 確定시켰다.

  • PDF

透析法에 依한 이온量 및 分子量의 決定에 關한 硏究 (第三報). 外部液量 및 透析溫度가 透析에 미치는 影響 (A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅲ). Effects of the Outer Solution Volume and the Dialyzing Temperature on Dialysis)

  • 신윤경;이전
    • 대한화학회지
    • /
    • 제18권2호
    • /
    • pp.138-142
    • /
    • 1974
  • 透析係數가 常數로 나타날 수 있는 條件究明으로서 透析質의 種類에 따르는 外部內의 畜積限界量을 究明하였고, 한편 透析係數와 透析溫度사이의 相關關係를 아울러 究明하였다.

  • PDF

복막투석환자의 소진요인과 대응양상에 관한 분석 (An Analysis of Burnout Factors and Coping Methods on Continuous Peritoneal Dialysis Patients)

  • 정영순;최귀순
    • 대한간호
    • /
    • 제34권2호
    • /
    • pp.66-76
    • /
    • 1995
  • This study was done to identify burnout factors and coping methods surveyed upon 59 out-patients who have continuous peritoneal dialysis. Raw data was collected after being filled the questionnaire by subjects or directly interviewing at the peritoneal dialysis room of the K hospital. Taegu. Then. data was classified and analyzed according to categories of questions and revealed facts. The following results are obtained: The average age of subjects is 43.8 years old and the average duration of continuous peritoneal dialysis is 16.9 months. The reasons of choosing continuous peritoneal dialysis are 61. 0% by recommendation of doctor and nurse ranked as the first, 32. 2% by patient own decision ranked as the second. The 57.6% of subjects were experienced complications related to continuous peritoneal dialysis. The major psychosocial burnout factors because of the dialysis are confinement, wasting time, change in responsibility and role as a member of family, worriment for infection, interference in job: and the major physiological burnout factors are fatigue and weakness. Among the main coping methods, the problem-oriented coping methods are "accept the given situation itself, "actively try to change the situation", "try to maintain some controls over the situation", and the affective-oriented coping method are "give up and accept as fate", "pray", "ask comfort or help from family and friends", "sleep", "cry". Conclusively, it can be said that effective nursing intervention is needed to prevent continuous peritoneal dialysis burnout.

  • PDF

透膜法에 依한 이온量 및 分子量의 決定에 關한 硏究 (I) 透析裝置 및 實驗方法의 改良 (A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅰ). Improvements of the Dialysis Apparatus and Its Operations)

  • 신윤경;이전
    • 대한화학회지
    • /
    • 제16권5호
    • /
    • pp.304-313
    • /
    • 1972
  • 溶解된 粒子의 이온量 또는 分子量을 決定하는 方法으로서의 透膜法에는 裝置의 未備點과 實驗方法의 改良되어야 할 點이 아직 남아 있으므로 우선 이들을 改善하여 補完하였다. 透析簡에 膜을 密着시킬수 있도록 鐵製링을 開發하였다. 透析液과 外部液의 水準을 0.02mm의 精度로 一致調節하고 維持시킴으로써 渗透 및 濾過效果를 最小限度로 抑制시켰다. 두 液의 攪拌速度를 任意의 定速度로 變更하여 그 攪拌量을 一定하게 維持할 수 있도록 하였으며, 그 溫度를 透析其間中 ${\pm}0.01^{\circ}C$의 精度로 一致維持시킬수 있도록 하였다. 透析期間中 透析液의 부피變化를 -1.62 ~ +0.92%範圍로 좁혔으며, 渗透 및 濾過效果와 膜孔의 크기와의 關係를 追究하여 最適透析時間을 究明하였다.

  • PDF