Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.
The aim of this study was to investigate the diagnostic value of superoxide dismutase (SOD) in tuberculous pleural effusions (TPEs) and malignant pleural effusions (MPEs). Pleural effusion (PE) samples from 100 patients were classified on the basis of diagnosis as TPE (n=57) and MPE (n=43). The activity of SOD was determined by pyrolgallol assay. A significant difference was observed in SOD activity (P<0.01) between TPE and MPE, levels of being significantly higher in TPE compared to MPE. With a threshold value of 41 U/L, the area under the ROC curve was 0.653, SOD had a sensitivity of 61.4% and a specificity of 61.0% for differential diagnosis. Thus, SOD activity in PE was not a good biomarker in differentiating TPE and MPE. To the best of our knowledge, five SOD isoforms may be present in PE. Identification of which SOD contributes to the difference of SOD level between TPE and MPE is very important for illustrating mechanisms and improving the differential diagnostic value.
The study aims to develop a novel, lead-free, flexible and lightweight composite shielding material against ionizing radiation. For this, it was used bismuth oxide (Bi2O3) in RTV-2 silicon matrix. The shielding tests were carried out in both diagnostic X-ray energies and intermediate gamma-ray energy range of up to 662 keV to determine the radiation attenuation properties of this material in terms of attenuation ratio, half value layer, tenth value layer, mean free path and lead equivalency of samples in weight of 30%, 40%, 50% in Bi2O3. In the diagnostic X-ray energy range, half value layer, tenth value layer and lead equivalency (in mm Pb) of the produced samples were measured at 80 and 100 kVp narrow beam conditions according to the requirements of EN IEC 61331-1 standard. The results show that lead equivalent values of the produced novel sheets was measured to be 0.16 mm Pb, corresponding to a 6 mm thickness of the flexible sample when it contains 30% wt. Bi2O3 in RTV matrix. The experimental findings for durability and flexibility also indicated that this new RTV-based flexible, lead -free shielding composite can be used safely for especially for manufacturing aprons, garments and thyroid guards used in mammography, radiology, nuclear medicine and dental applications in practice.
Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.
The Transactions of the Korean Institute of Electrical Engineers A
/
v.49
no.5
/
pp.242-251
/
2000
In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.
The evaluation of diagnostic tests attempts to obtain one or more statistical parameters which can indicate the intrinsic diagnostic utility of a test. Sensitivity. specificity and predictive value are not appropriate for this use. The likelihood ratio has been proposed as a useful measure when using a test to diagnose one of two disease states (e.g. disease present or absent). In this paper, we generalize the likelihood ratio concept to a situation in which the goal is to diagnose one of several non-overlapping disease states. A formula is derived to determine the post-test probability of a specific disease state. The post-test odds are shown to be related to the pre-test odds of a disease and to the usual likelihood ratios derived from considering the diagnosis between the target diagnosis and each alternate in turn. Hence, likelihood ratios derived from comparing pairs of diseases can be used to determine test utility in a multiple disease diagnostic situation.
Purpose : This study was to investigate the influence of heart rate and coronary calcification on diagnostic accuracy of 64-slice multidetector CT(MDCT) in coronary artery disease. Methods : 178 patients(84 men, 94 women) undergoing cardiac CT were included in this study. 3 coronary arteries(LAD, LCX, RCA) were assessed the presence of significant stenosis($\geq50%$) and the results compared with those of coronary angiography. Results : On a patient-based analysis, the diagnostic accuracy of 64-slice MDCT was 96.6%. The diagnostic accuracy on left anterior descending, left circumflex, right coronary artery were 86.5%, 84.3%, 92.1% respectively. Body mass index and blood pressure were not influenced on diagnostic accuracy of 64-slice MDCT. In less than 60/min of heart rate, accuracy was 90.1% and $\kappa$ value was 0.78. While in more than 70/min of heart rate, accuracy was 75.8% and $\kappa$ value was 0.52. In less than 100 of coronary calcification, accuracy was 91.3% and $\kappa$ value was 0.81. While in more than 400, accuracy was 68.6% and $\kappa$ value was 0.33. Conclusion : 64-slice MDCT shows similar diagnostic accuracy as coronary angiography. But in the context of more than 70/min of heart rate and 400 of coronary calcification, diagnostic accuracy was decreased. So there needs to identify heart rate and coronary calcification in cardiac CT, and if heart rate shows more than 70/min, use beta-blocker to regulate it.
Background: Nodal invasion by colorectal cancer is a critical determinant in estimating patient survival and in choosing appropriate preoperative treatment. The present meta-analysis was designed to evaluate the diagnostic value of endorectal ultrasound (EUS) in preoperative assessment of lymph node involvement in colorectal cancer. Materials and Methods: We systematically searched PubMed, Web of Science, Embase, and China National Knowledge Infrastructure (CNKI) databases for relevant studies published on or before December 10th, 2014. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and area under the summary receiver operating characteristics curve (AUC) were assessed to estimate the diagnostic value of EUS. Subgroup analysis and meta-regression were performed to explore heterogeneity across studies. Results: Thirty-three studies covering 3,016 subjects were included. The pooled sensitivity and specificity were 0.69 (95%CI: 0.63-0.75) and 0.77 (95%CI: 0.73-0.82), respectively. The positive and negative likelihood ratios were 3.09 (95%CI: 2.52-3.78) and 0.39 (95%CI: 0.32-0.48), respectively. The DOR was 7.84 (95%CI: 5.56-11.08), and AUC was 0.80 (95%CI: 0.77-0.84). Conclusions: This meta-analysis indicated that EUS has moderate diagnostic value in preoperative assessment of lymph node involvement in colorectal cancer. Further refinements in technology and diagnostic criteria are necessary to improve the diagnostic accuracy of EUS.
Nam Hee Kim;Sung Ryol Lee;Young Hwan Kim;Hong Joo Kim
Korean Journal of Radiology
/
v.21
no.12
/
pp.1355-1366
/
2020
Objective: We aimed to evaluate the diagnostic value and prognostic relevance of FDG positron emission tomography/computed tomography (PET-CT) in extrahepatic cholangiocarcinoma patients. Materials and Methods: This study included 234 extrahepatic cholangiocarcinoma patients who underwent FDG PET-CT between June 2008 and February 2016. The diagnostic performance of FDG PEG-CT was compared to that of contrast-enhanced multidetector row CT (MDCT) and MRI. Independent prognosticators for poor survival were also assessed. Results: The sensitivity of FDG PET-CT for detecting primary tumor and regional lymph node metastases was lower than that of MDCT or MRI (p < 0.001), whereas the specificity and positive predictive value for detecting regional lymph nodes metastases was significantly better in FDG PET-CT compared to MDCT and MRI (all p < 0.001). There was no significant difference in the diagnostic yield of distant metastases detection among three diagnostic imaging techniques. In a multivariate analysis, maximum standardized uptake values (SUVmax) of the primary tumor (adjusted hazard ratio [HR], 1.75; 95% confidence interval [CI], 1.13-2.69) and of the metastatic lesions ≥ 5 (adjusted HR, 8.10; 95% CI, 1.96-33.5) were independent contributors to poor overall survival in extrahepatic cholangiocarcinoma patients. In a subgroup analysis of 187 patients with periductal infiltrating type of cholangiocarcinoma, an SUVmax of the primary tumor ≥ 5 was associated with an increased risk of regional lymph node (adjusted odds ratio [OR], 1.60; 95% CI, 0.55-4.63) and distant metastases (adjusted OR, 100.57; 95% CI, 3.94-2567.43) at diagnosis as well as with poor overall survival (adjusted HR, 1.81; 95% CI, 1.04-3.15). Conclusion: FDG PET-CT showed lower sensitivity for detecting primary tumor and regional lymph node involvement than MDCT and MRI. However, the SUVmax of primary tumors and metastatic lesions derived from FDG PET-CT could have significant implications for predicting prognoses in extrahepatic cholangiocarcinoma patients.
Deniz Yasemin;Sang-Woo Pyun;HyungSu Lee;Seong-Eun Kim;SunGyu Han;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Seong-gil Kim
The Journal of Korean Physical Therapy
/
v.35
no.3
/
pp.57-63
/
2023
Purpose: The aim of this study was to conduct a systematic review of randomized controlled studies from 2012 to present that explore the diagnostic accuracy of clinical tests used for diagnosing anterior cruciate ligament (ACL) injury. Methods: Study design: Systematic review. Literature search of the PubMed and Scholar databases was conducted using keywords related to diagnostic accuracy of clinical tests for ACL injury. The PRISMA Guidelines were followed to conduct this study. The Cochrane Risk of Bias Tool was utilized to assess the quality of each included study. Results: As a result, 8 studies were included, and 6 clinical tests used in ACL tears were evaluated for diagnostic accuracy. The pivot shift test was reported as having the highest +LR (29.5) value with a sensitivity of 59% and a specificity of 98%. However, the test with the lowest -LR value was the lever test, and the values were as follows: -LR (0.08), +LR (4.7), specificity (80%), sensitivity (94%). Conclusion: In this study, it was concluded that a single clinical test is not sufficient to determine the presence of ACL injury. Test combinations have a higher diagnostic accuracy than a single test. In this study, the accuracy of the clinical tests was examined without considering the amount of ACL rupture and acute-chronic condition. Further research is required to examine the impact of these two factors on diagnostic accuracy of clinical test.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.