• Title/Summary/Keyword: Diagnostic sensor

Search Result 239, Processing Time 0.036 seconds

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

Fabrication of Piezoelectric Cantilever with Microcone Tip for Sensing Local Stiffness of Biological Tissue (생체 조직의 국소 강도 측정을 위한 마이크로 콘 팁을 가진 압전 캔틸레버 제작)

  • Roh, Hee Chang;Yang, Dasom;Ryu, WonHyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.743-748
    • /
    • 2017
  • For diseases that are difficult to detect by conventional imaging techniques, the development of a diagnostic method that allows sensors to be inserted into the human body to aid the diagnosis of local spots of the target tissue, is highly desirable. In particular, it is extremely difficult to determine whether vulnerable plaque can later develop into atherosclerosis using only imaging techniques. However, vulnerable plaques are expected to have slightly different mechanical properties than healthy tissue. In this study, we aim to develop a piezoelectric cantilever-type sensor that can be inserted into the human body and can detect the local mechanical properties of the target tissue. A piezoelectric polymer composite based on $BaTiO_3$ nanoparticles was optimized for fabrication of a piezoelectric cantilever. Next, a micro-cone tip was fabricated at the end of the piezoelectric cantilever by thermal drawing. Finally, stiffness of biological tissue samples was measured with the piezoelectric cantilever sensor for verifying its functionality.

Improvement Research of BLE-based System for Monitoring the cause of Breakdown of Automatic Doors (자동문의 고장원인을 모니터링하기 위한 BLE 기반의 시스템 개선연구)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.93-102
    • /
    • 2017
  • Recently increasing usage of smartphones makes the Internet of Things (IoT) a leading technology that can collect and share data through sensor networks and wireless communication such as low-power Bluetooth (BLE). BLE-based application can provide operators more precise information on Automatic Door system by remotely diagnosing the system faults through wireless sensor networks and sensors around the Automatic Door. In this paper, a smart device with extended BLE module is implemented which can monitor and Control the system states and faults remotely without on-site diagnostic. while maintaining system integrity so that increase efficiency of time and costs for system management. We can use the results of this research as a basis in evaluating reliability of data between devices, extending communication module in Controller of obsolete Door systems, and establishing centralized monitoring systems in near future with multi-channel Door Controls.

Integration of Application Program for Dementia Diagnosis using Biometric Sensor and Oxygen Chamber (생체센서를 이용한 치매진단용 어플리케이션 프로그램과 산소챔버의 융합)

  • Cho, Myeon-Gyun;Choi, Hyo Sun;Kim, Hyeong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5847-5855
    • /
    • 2013
  • The purpose of this research is to develop Dementia-diagnosis application program through inter-working between biometric sensors and smart phone with diagnostic programs. Receiving data from 2 biometric sensors, SpO2 and HRV(heart rate variability) with Bluetooth and adding scores from questionnaires and memory test game, smart phone can draw a final Dementia Index(DI). Simple clinical tests provided threshold for Dementia, and diagnosis was made by comparing the DI with the threshold. We performed testing on persons aged over 60 and found out the proposed application can be used to diagnose Dementia easily and quickly. Additionally, we have shown the potential of oxygen chamber combined with Dementia-diagnosis application as a medical equipment to ease or cure Dementia in its early stages.

Multi-block PCA for Sensor Fault Detection and Diagnosis of City Gas Network (도시가스 배관망의 고장 탐지 및 진단을 위한 다중블록 PCA 적용 연구)

  • Yeon-ju Baek;Tae-Ryong Lee;Jong-Seun Kim;Hong-Cheol Ko
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.38-46
    • /
    • 2024
  • The city gas pipeline network is characterized by being widely distributed and hierarchically connected in a complex manner over a wide area. In order to monitor the status of the widely distributed network pressures with high precision, Multi-block PCA(MBPCA) is recommended. However, while MBPCA has excellent performance in identifying faulty sensors as the number of sensors increases, the fault detection performance deteriorates, and also there is a problem that the model needs to be updated entirely even if minor changes occur. In this study, we developed fault detectability index and fault identificability index to determine the effectiveness of MBPCA application block by block. Based on these indices, we distinguished MBPCA and PCA blocks and developed a fault detection and diagnostic system for the city gas pipeline network of Haean Energy Co., Ltd., and were able to solve the problems that arise when there are many sensors.

Digital contrast subtraction radiography for proximal caries diagnosis (인접면 치아우식 진단을 위한 디지털 방사선 조영 공제술)

  • Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.123-127
    • /
    • 2002
  • Purpose : To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Materials and Methods: Thirty-six teeth with 57 proximal surfaces were radiographied using a size #2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. Results: The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. Conclusion: The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  • PDF

Fabrication and characteristics of multilevel acoustic Fresnel lens for ultrasonic transducer for diagnostic imaging (영상진단용 초음파 트랜스듀서를 위한 멀티레벨 음향 프레넬 렌즈의 제작 및 특성)

  • Kim, Dong-Hyun;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 2009
  • A multilevel acoustic Fresnel lens (MAFL) for the ultrasonic imaging transducer of which center frequency is approximately 5.MHz was newly designed and fabricated. The phase level of the lens was 64, and the focal length and the aperture width were 30.mm and 11.mm, respectively. The characteristics of impulse response, acoustic field and imaging performance of the transducer attached the lens were compared with the transducer attached a conventional refraction type acoustic lens (RAL). The results show that the center frequency, the loop sensitivity, and the focal depth of the MAFL transducer were higher or larger than those of the RAL transducer by approximately 0.2.MHz, 1.4.dB, and 2.mm, respectively. Consequently, it was shown that the brighter acoustic images with higher lateral resolution and the increased imaging performance for deep targets can be obtained by using the MAFL transducer.

Source localization technique for metallic impact source by using phase delay between different type sensors (다종 센서간 위상 차이를 이용한 충격 위치추정 기법)

  • Choi, Kyoung-Sik;Choi, Young-Chul;Park, Jin-Ho;Kim, Whan-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.687-692
    • /
    • 2008
  • In a nuclear power plant, loose part monitoring and its diagnostic technique is one of the major issues for ensuring the structural integrity of the reactor system. Typically, accelerometers are mounted on the surface of a reactor vessel to localize impact location caused by the impact of metallic substances on the reactor system. However, in some cases, the number of the accelerometers is not enough to estimate the impact location precisely. In such a case, one of alternative plan is to utilize another type sensors that can measure the vibration of the reactor structure even though the measuring frequency ranges are different from each others. The AE sensors installed on the reactor structure can be utilized as additional sensors for loose part monitoring. In this paper, we proposed a new method to estimate impact location by using both accelerometer signal and AE signal, simultaneously. The feasibility of the proposed method is verified by an experiment. The experimental results demonstrate that we can enhance the reliability and precision of the loose part monitoring.

  • PDF

A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine (고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구)

  • Oh, Bong-Keun;Kang, Dong-Sik;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

Voltammetric Determination of Droxidopa in the Presence of Tryptophan Using a Nanostructured Base Electrochemical Sensor

  • Yaghoubian, Halimeh;Jahani, Shohreh;Beitollahi, Hadi;tajik, Somayeh;Hosseinzadeh, Rahman;Biparva, Pouria
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.109-117
    • /
    • 2018
  • A novel carbon paste electrode modified with $Cu-TiO_2$ nanocomposite, 2-(ferrocenylethynyl)fluoren-9-one (2FF) and ionic liquid (IL) (2FF/$Cu-TiO_2$/IL/CPE) was fabricated and employed to study the electrocatalytic oxidation of droxidopa, using cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV) as diagnostic techniques. It has been found that the oxidation of droxidopa at the surface of modified electrode occurs at a potential of about 295 mV less positive than that of an unmodified CPE. DPV exhibits a linear dynamic range from $5.0{\times}10^{-8}$ to $4.0{\times}10^{-4}M$ and a detection limit of 30.0 nM for droxidopa. Finally this modified electrode was used for simultaneous determination of droxidopa and tryptophan. Also the 2FF/$Cu-TiO_2$/IL/CPE shows excellent ability to determination of droxidopa and tryptophan in real samples.