• Title/Summary/Keyword: Diagnostic sensitivity

Search Result 1,234, Processing Time 0.035 seconds

Diagnostic Value of Flow Cytometric DNA Analysis in the Evaluation of Effusions (체강삼출액의 진단에 있어서 유세포분석에 의한 DNA 함량 측정의 유용성)

  • Lee, Ji-Shin;Juhang, Sang-Woo
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 1997
  • The specificity of cytologic examination in effusions is high but the sensitivity is low. Therefore, various ancillary methods for the detection of malignant cells in effusions have been proposed. The presence of an aneuploid cell population is generally considered diagnostic of malignancy. The purpose of this study is to determine whether the routine use of flow cytometry adds to standard cytologic evaluation in effusions. We did flow cytometric DNA analysis in 76 effusions(28 malignant and 48 benign fluids). All the 48 benign effusions were diploid. There were 12(42.9%) aneuploid and 16(67.1%) diploid malignant effusions. Based on these results flow cytometric DNA analysis had a sensitivity of 42.9% and a specificity of 100%. These results suggest that flow cytometric DNA analysis may be a useful adjunct to conventional cytology, but its principal limitation is us relatively low sensitivity.

  • PDF

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Diagnostic Accuracy of Urease and Polymerase Chain Reaction to Detect Helicobacter Species Infection in Dogs (개에서 Helicobacter균 감염을 검출하기 위한 urease 검사와 PCR 검사의 진단적 정확도)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.329-333
    • /
    • 2001
  • Evaluation on the diagnostic performances of urease test and polymerase chain reaction (PCR) for detection of Helicobacter species infection in dogs has rarely been performed in research with site-specific situations, although assessing diagnostic tests is an essential part prior to its practical use in a variety of clinical settings. The clinical value of a diagnostic test may be misjudged and comparisons between different tests may yield misleading conclusions when high within-patient correlations are present. We applied a conceptually simple statistical approach to estimate the sensitivity and specificity of urease test and PCR for detection of Helicobacter species infection in dogs. This approach assumes that responses from three different sampling sites within an animal are correlated where unit for statistical analysis is the site rather than the animal. The sensitivity and specificity of urease test was 0.74% (95% confidence interval, 0.64-0.84) and 0.87 (95% CI, 0.67-1.00), respectively. For PCR, the sensitivity was 0.95(95% CI, 0.89-1.00) and specificity 0.90 (95% CI, 0.70-1.00). Two tests were almost equally specific. Urease test, however, has a lower diagnostic accuracy and thus should only be used after careful validation in terms of sensitivity.

  • PDF

Diagnostic and Prognostic Importance of the Neutrophil Lymphocyte Ratio in Breast Cancer

  • Ozyalvacli, Gulzade;Yesil, Cemile;Kargi, Ertugrul;Kizildag, Betul;Kilitci, Asuman;Yilmaz, Fahri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10363-10366
    • /
    • 2015
  • Background: The aim of this study was to determine diagnostic and prognostic roles of the neutrophil to lymphocyte ratio (NLR) in breast cancer patients. To date, data are limited on associations of primary breast carcinoma (PBC) and benign proliferative breast disease (BPBD) with preoperative NLR values. Materials and Methods: Our study covered of 120 female patients with PBC and 50 with BPBD. Diagnostic values of NLR were estimated using sensitivity, specificity and areas under receiver operating characteristic curves (AUC). Results: NLR values were significantly higher in the PBC patients than in those with BPBD, with an AUC of 0.668 in the PBC case. The optimal cut-off for NLR was 2.96 and this was validated in the testing set, giving a sensitivity and a specificity of 79.7% and 76.2%, respectively, in PBC patients. Conclusions: Preoperative high NLR is a significant diagnostic predictor of distinction of breast cancer from BPBD and elevated NLR is also an important prognostic marker for primary invasive breast cancer.

Support Vector Machine Based Diagnostic System for Thyroid Cancer using Statistical Texture Features

  • Gopinath, B.;Shanthi, N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 2013
  • Objective: The aim of this study was to develop an automated computer-aided diagnostic system for diagnosis of thyroid cancer pattern in fine needle aspiration cytology (FNAC) microscopic images with high degree of sensitivity and specificity using statistical texture features and a Support Vector Machine classifier (SVM). Materials and Methods: A training set of 40 benign and 40 malignant FNAC images and a testing set of 10 benign and 20 malignant FNAC images were used to perform the diagnosis of thyroid cancer. Initially, segmentation of region of interest (ROI) was performed by region-based morphology segmentation. The developed diagnostic system utilized statistical texture features derived from the segmented images using a Gabor filter bank at various wavelengths and angles. Finally, the SVM was used as a machine learning algorithm to identify benign and malignant states of thyroid nodules. Results: The SVMachieved a diagnostic accuracy of 96.7% with sensitivity and specificity of 95% and 100%, respectively, at a wavelength of 4 and an angle of 45. Conclusion: The results show that the diagnosis of thyroid cancer in FNAC images can be effectively performed using statistical texture information derived with Gabor filters in association with an SVM.

Diagnostic Accuracy of Dermoscopy for Scabies

  • Li, Feng-Zeng;Chen, Shuang
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.669-674
    • /
    • 2020
  • The diagnostic accuracy of dermoscopy (DS) for scabies, a highly contagious parasitic disease, remains disputed. This study aimed to assess the diagnostic accuracy of DS in scabies, analyze the factors influencing DS, and explore its role in post-treatment evaluation. Patients with suspected scabies were randomly divided into 2 groups: 71 patients in the skin scraping (SS) group and 73 patients in the DS group. The diagnostic efficiencies of SS and DS in these groups were calculated. We also analyzed the influence of body part and investigator competence on the accuracy of DS. Then 16 body parts with typical signs of scabies were monitored by DS 2 and 4 day after sulfur ointment treatment. The sensitivity and specificity of DS were 98.3% and 88.5%, respectively. Hands, arms, and the abdomen had higher positivity rates than other body parts (P<0.001). The accuracy of dermatologists' interpretations of images negative for scabies in the intermediate- and high-level groups was higher than that in the low-level group (P<0.001). At follow-up, the mites were still visible on 43.8% to 62.5% of the skin lesions 2 and 4 day after sulfur ointment treatment. These results showed that DS could significantly increase the accuracy of diagnosing scabies owing to its high sensitivity and specificity. Therefore, it may be useful for monitoring clinical responses to anti-parasitic treatment.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

Diagnosis of Recurrent Uterine Cervical Cancer: Computed Tomography versus Positron Emission Tomography

  • Dong Hee Park;Kie Hwan Kim;Sang Yoon Park;Byung Hee Lee;Chang Woon Choi;Soo Yil Chin
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 2000
  • Objective: To determine the accuracy of CT and positron emission tomography (PET) in the diagnosis of recurrent uterine cervical cancer. Materials and Methods: Imaging findings of CT and PET in 36 patients (mean age, 53 years) in whom recurrent uterine cervical cancer was suspected were analyzed retrospectively. Between October 1997 and May 1998, they had undergone surgery and/or radiation therapy. Tumor recurrence was confirmed by pathologic examination or follow-up studies. Results: In detecting recurrent uterine cervical cancer, the sensitivity, specificity, and accuracy of CT were 77.8%, 83.3%, and 80.5%, respectively, while for PET, the corresponding figures were 100%, 94.4%, and 97.2%. The Chi-square test revealed no significant difference in specificity (p = .2888), but significant differences in sensitivity (p = .0339) and accuracy (p = .0244). Conclusion: PET proved to be a reliable screening method for detecting recurrent uterine cervical cancer, but to determine the anatomical localization of recurrent tumors, and thus decide an adequate treatment plan, CT was eventually needed.

  • PDF

Diagnostic Value of Human Epididymis Protein 4 Compared with Mesothelin for Ovarian Cancer: a Systematic Review and Meta-analysis

  • Lin, Jia-Ying;Qin, Jin-Bao;Li, Xiao-Yan;Dong, Ping;Yin, Bing-De
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5427-5432
    • /
    • 2012
  • Background and Purpose: Ovarian cancer is the leading cause of death among gynecologic cancers because of the lack of effective early detection methods. Accuracies of the human epididymis protein 4 (HE4) and mesothelin in detecting ovarian cancer have never been systematically assessed. The current systematic review aimed to tackle this issue. Methods: MEDLINE, EMBASE, and Cochrane databases were searched (September 1995-November 2011) for studies on the diagnostic performances of HE4 and mesothelin in differentiating ovarian cancer from other benign gynecologic diseases. QUADAS items were used to evaluate the qualities of the studies. Meta-DiSc software was used to handle data from the included studies and to examine heterogeneity. All included studies for diagnostic performance were combined with sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratios (DORs) with 95% confidence intervals (CIs), summary receiver operating characteristic (SROC) curves, and areas under the SROC curves (AUC). Results: A total of 18 studies and 3,865 patients were eligible for the final analysis. The pooled sensitivity estimates for HE4 (74.4%) were significantly higher than those for mesothelin (49.3%). The pooled specificity estimates for mesothelin (94.5%) were higher than those for HE4 (85.8%). The pooled DOR estimates for HE4 (26.22) were higher than those for mesothelin (24.01). The SROC curve for HE4 showed better diagnostic accuracy than that for mesothelin. The PLR and NLR of HE4 were 6.33 (95% CI: 3.58 to 11.18) and 0.27 (95% CI: 0.21 to 0.34), respectively. The PLR and NLR for mesothelin were 11.0 (95% CI: 6.21 to 19.59) and 0.51 (95% CI: 0.42 to 0.62), respectively. The combination of the two tumor markers or their combination with CA-125 increased sensitivity and specificity to different extents. Conclusion: The diagnostic accuracy of HE4 in differentiating ovarian cancer from other benign gynecologic diseases is better than that of soluble mesothelin-related protein. Combinations of two or more tumor markers show more sensitivity and specificity.