• Title/Summary/Keyword: Diagnostic radiography examination

Search Result 114, Processing Time 0.02 seconds

Assessment of panoramic radiography as a national oral examination tool: review of the literature

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose : The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. Materials and Methods : This report was carried out by review of the literatures. Results : Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Conclusion : Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

Evaluation of the Chest Radiography using Fuji Computed Radiography(FCR) System (Fuji Computed Radiography(FCR)를 이용한 흥부 X선사진의 평가)

  • Kim, Young-Sung;Kwang, Nam-Sun;Yeo, Young-Bok;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 1991
  • Chest radiograms obtained by using Fuji Computed Radiography(FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic informations than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

  • PDF

A Study on the Effect of the Environmental Improvement in the Diagnostic Radiography Room on Patients (진단방사선과 검사실의 환경개선이 환자에게 미치는 영향에 관한 연구)

  • Kweon, Dae Cheol;Hong, Sung Man;Kim, Dong Sung;Park, Peom
    • Quality Improvement in Health Care
    • /
    • v.9 no.1
    • /
    • pp.90-100
    • /
    • 2002
  • Background : This study was attempted to provide us with basic data on how to environmental improvement with patients for examination, and to offer them better treatment. This study was performed to compare the patients, perception between before and after improvement in the diagnostic radiography room. Methods : The data was collected by interviewing 75 patients who underwent the radiography under the diagnostic radiology at Seoul National University Hospital in Korea. The interview ran from August 9 to October 18, 1999. Data were analyzed by percentage and paired t-test. SD(Semantic Differential) method was composed of adjective 13 words. Results : Patients were attending the elementary schools in the Seoul residents. There was no significant difference in kindness unkindness dimension and were significant differences in other dimensions. The mean score of response level to present room was 3.67 and that of improvement room was 2.16. Conclusions : The results of this study suggest a radiography room plan which is considering emotional aspect of children.

  • PDF

A Huge Intra-Abdominal Mass Associated with Long-Term Surgical Gauze Retention in a Toy Breed Dog

  • Lee, Sung-Jun;Jeong, Soon-Wuk;Eom, Ki-Dong;Shin, Jong-Il;Yoon, Hun-Young
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.116-121
    • /
    • 2016
  • A 1.83 kg, 9-year-old, spayed female Yorkshire Terrier was referred to the Veterinary Medical Teaching Hospital of Konkuk University for evaluation of an intra-abdominal mass with a week history of vomiting and diarrhea. On physical examination, survey radiography, abdominal ultrasonography, and computed tomography, a huge firm mass was identified in the mid-caudal abdomen. Surgical exploration of the abdominal cavity was performed to remove the mass. The encapsulated mass adhered to the mesentery, tail of the spleen, small intestine, omentum, and right lobe of the pancreas was removed using blunt dissection with dry gauze and cotton swabs. Macroscopic and histopathological examination revealed that the mass was foreign-body granuloma consistent with gauze fiber. Plain abdominal radiography demonstrated no remarkable findings 8 months post-operatively. There was no evidence of vomiting, diarrhea, coughing, difficulty breathing, and cyanosis on exertion 13 months post-operatively.

The Study about the Positioning Block Artifact in Digital Radiography Environment (Digital Radiography 환경에서 Positioning Block Artifact에 관한 연구)

  • Kim, Byung-Ki;Choi, Jun-Gu;Lee, Jun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • Purpose : In sponge quality of the material in digital radiography environment coating because do position blocks two that do not become coating done positioning blocks two that do not become coating done positioning block and sponge quality of the material to testing bench image artifact's difference compare. Method of study : In digital radiography environment positioning block of different two products same sunshine or effect that image and positioning block artifact gents in image analyze. the target used positioning block 2 when examine hand, rib and examination condition did each differently according to used positioning block. reflex compared picture that do image and verify that examine first time. Result : 1. In sponge quality of the material coating in done product artifact appear. Did not appear in product that do not become coating. 2. Can know coating's existence, that artifact according to radish happens. 3. Quality of the material coating's existence, there was difference of slippage according to radish Conclusion : Quality of the material coating phenomenon that done positioning block thus, it may have to be considered that use after estimate degree that get in image.

  • PDF

The Value of Periapical Radiograph in the Diagnosis of Interproximal Caries (구내방사선사진의 인접면 치아우식 진단에 대한 유용성 평가)

  • Kim Young-Hee;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Purpose : To compare the diagnostic performance of clinical and radiologic examination for the interproximal caries on intraoral periapical radiographs and to evaluate the value of periapical radiographs. Methods: One hundred seven dental patients were examined clinically, with a mouth mirror and an explorer, by a dentist at the department of oral medicine, and the presence or absence of interproximal caries lesion was recorded. The patients were prescribed one or more dental periapical radiographs. Radiographs were assessed for the presence of interproximal caries by three oral and maxillofacial radiologists independantly. Two thousand sixty interproximal surfaces were included in this study. The diagnostic accuracies of clinical and radiologic examinations for interproximal caries were calculated. To assess the degree of agreement between clinical and radiologic examinations, Cohen's coefficient of agreement was computed. Results: The specificity of clinical and radiologic examination was 0.991, 0.997 and the sensitivity was 0.279, 0.985 respectively. The diagnostic accuracy of radiologic examination was statistically significantly higher than that of clinical examination (P<0.05). Cohen's kappa value of clinical and radiologic examination was 0.335, 0.942 respectively. These results suggested that clinical examination show only fair agreement, whereas radiologic examination show perfect agreement. Conclusion: The diagnositic performance of the dental periapical radiographs on interproximal caries were higher than that of clinical examination, thus this study showed the validity of periapical radiographs for detecting interproximal caries lesion without bitewing radiograph.

  • PDF

Diagnostic Radiography of Premature Closure of Distal Growth Plate of Ulna in a Dog (개에서 척골의 원위 성장판 조기 폐쇄증에 대한 방사선학적 평가)

  • 송경진;이희천;이기창;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.403-405
    • /
    • 2003
  • A 11 month-old Shihtzu was referred to the Veterinary Medical Teaching Hospital, Seoul National University. Clinical signs of this patient were lameness, shortening limb, angular deformity, rotation of foot, subluxaion of elbow joint and restricted range of movement of left forelimb. For the evaluation of the abnormalities of left forelimb, radiographic examination was carried out. Radiographic findings were characteristics of premature closure of distal ulna such as closure of distal ulna growth plate and cranial bowing of radius. With radiographic signs and physical examination, it was diagnosed as premature closure of growth plate of the left forelimb. After osteotomy of the radius and ostectomy of the ulna, radiographic evaluation of limb about angulation of elbow joint was performed every 2-3 weeks for 3 months. In case of premature closure of distal growth plate of ulna, radiography was very useful for diagnositic method of premature closure of distal ulna and monitoring of healing process.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Jeong, Man-Hee;Im, Eun-Kyung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Methods on Simple Radiography of Impingement Syndrome in Shoulder Joint (견관절 충돌증후군의 단순X선촬영 방법에 대한 검토)

  • Kweon, Dae-Cheol;Kim, Moon-Sun;Kim, Yong-Seob;Chung, Kyung-Mo
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.21-27
    • /
    • 2000
  • To evaluation of patients who have shoulder impingement syndrome is by diagnostic radiography. Shoulder impingement is a problem which occurs in young, active individuals as well as older individuals. In fact, the pain is probably caused by repetitive stress placed on the shoulder joint either through recreational activities of your occupation. Impingement series approach to radiographic examination of the shoulder is take five projections. First anteroposterior oblique projection. Second standard anteroposterior projection. Third superoinferior axial projection. Fourth supraspinatus outlet projection offers a view of the outlet of the supraspinatus tendon unit as it passes under the coraacromial arch. Fifth anteroposterior $30^{\circ}$ caudal projection will adequately demonstrate the anterior acromial spur or ossification in the coraacromial ligament and more reliable to demonstrate spurring of the anterior acromion than supraspinatus outlet projection. This decreased the need for additional radiographic veiws, reduces the patient's exposure to x - ray radiation and decreases use of film. This can lower the cost of the evaluation and improve patient satisfaction.

  • PDF