• 제목/요약/키워드: Diagnostic performance

검색결과 904건 처리시간 0.03초

공기구동밸브 성능 진단 장비 개발 (Development of the Diagnostic System for the Performance of Air-Operated Valves)

  • 김윤철;강성기;박성근;김대웅;채장범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.416-419
    • /
    • 2008
  • In order to ensure the safety, the performance evaluation of the safety-related components in a nuclear power plant such as air-operated valves. In this paper, the diagnostic system(MOVIDS $A^+$) for the performance of air-operated valves was developed. For this purpose, the characteristics of their operation and the methods of the diagnostic tests were reviewed. The setup and diagnostic functions of the system were mentioned. Its applicability was validated through the diagnostic tests of air-operated valves in nuclear power plants. This diagnostic system is now applied in nuclear power plants for performance tests.

  • PDF

진단검사 정확도 평가지표의 신뢰구간 (The Use of Confidence Interval of Measures of Diagnostic Accuracy)

  • 오태호;박선일
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.319-323
    • /
    • 2015
  • The performance of diagnostic test accuracy is usually summarized by a variety of statistics such as sensitivity, specificity, predictive value, likelihood ratio, and kappa. These indices are most commonly presented when evaluations of competing diagnostic tests are reported, and it is of utmost importance to compare the accuracies of diagnostic tests to decide on the best available test for certain medical disorder. However, it is important to emphasize that specific point values of these indices are merely estimates. If parameter estimates are reported without a measure of uncertainty (precision), knowledgeable readers cannot know the range within which the true values of the indices are likely to lie. Therefore, when evaluations of diagnostic accuracy are reported the precision of estimates should be stated in parallel. To reflect the precision of any estimate of a diagnostic performance characteristic or of the difference between performance characteristics, the computation of confidential interval (CI), an indicator of precision, is widely used in medical literatures in that CIs are more informative to interpret test results than the simple point estimates. The majority of peer-reviewed journals usually require CIs to be specified for descriptive estimates, whereas domestic veterinary journals seem less vigilant on this issues. This paper describes how to calculate the indices and associated CIs using practical examples when assessing diagnostic test performance.

구내방사선 사진상의 인접면 치아우식진단능 평가 (Diagnostic Performance of the Intraoral Radiographs on the Interproximal Dental Caries)

  • 김수지;강병철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.37-46
    • /
    • 1998
  • The purpose of this study was to evaluate the diagnostic performance of the senior dental students for the proximal dental caries on intraoral radiographs and to compare it with the dental hospital residents, the reference group. It was also investigated the diagnostic performance according to the carious lesion depth. Thirty-five intraoral periapical and bitewing radiographs with 213 proximal surfaces included in this study were selected from the dental patients at Chonnam National University Hospital. The observers were 181 senior dental students from 5 dental schools and 40 dentists who were second year resident from 5 dental hospitals. They were asked to evaluate the presence or the absence of the proximal dental caries. The results were as follows: 1. The mean of the hitting rate for the overall observers was 184.51 surfaces and the diagnostic accuracy was 86.62%. 2. The diagnostic performance of the sound proximal tooth surfaces was very high, i.e., 91.5% true negative rate and 8.5% false positive rate. 3. The diagnostic performance of the dentist group was higher than the student group(P<0.05). 4. The proximal dental caries perceptibility increased as the lesion depth increased significantly(P<0.001) except no difference between the carious lesion depth III and IV (P>0.001).

  • PDF

Development of On-line Performance Diagnostic Program of a Helicopter Turboshaft Engine

  • Kong, Chang-Duk;Koo, Young-Ju;Kho, Seong-Hee;Ryu, Hye-Ok
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제10권2호
    • /
    • pp.34-42
    • /
    • 2009
  • Gas turbine performance diagnostics is a method for detecting, isolating and quantifying faults in gas turbine gas path components. On-line precise fault diagnosis can promote greatly reliability and availability of gas turbine in real time operation. This work proposes a GUI-type on-line diagnostic program using SIMULINK and Fuzzy-Neuro algorithms for a helicopter turboshaft engine. During development of the diagnostic program, a look-up table type base performance module are used for reducing computer calculating time and a signal generation module for simulating real time performance data. This program is composed of the on-line condition monitoring program to monitor on-line measuring performance condition, the fuzzy inference system to isolate the faults from measuring data and the neural network to quantify the isolated faults. Evaluation of the proposed on-line diagnostic program is performed through application to the helicopter engine health monitoring.

Agreement of two ELISAs for Mycobacterium avium subspecies paratuberculosis in cattle in Korea

  • Lee, Kyung Woo;Jung, Byeong Yeal;Hwang, In Yeong;Lee, Su Hwa;Kim, Ji Yeon;Kim, Young Hoan;Lee, Seong Hyo;Moon, Oun Kyoung;Lee, O Soo
    • 대한수의학회지
    • /
    • 제49권2호
    • /
    • pp.121-125
    • /
    • 2009
  • Paratuberculosis caused by Mycobacterium avium subspecies paratuberculosis (Mpt) is a chronic infectious enteric disease with deleterious impact on the performance in ruminants. In Korea, ELISA has been introduced to detect antibodies to Mpt in individual cattle. However, comparison study with ELISA has not been studied until now. In total, a panel of 899 serum samples obtained from dairy cattle was analyzed with two commercial ELISAs for Mpt to assess the performance. Two ELISAs employed in this study were both licensed worldwide. Two ELISAs applied onto same serum samples showed the moderate agreement (kappa value = 0.60). There was non-significant McNemar test (p = 0.0614) between two ELISA results indicating that each proportion detected by two kits did not differ. In addition, the percent agreement between two ELISA results was turned out to be 96.8% which interpreted excellent reproducibility. It was shown from this study that two ELISAs revealed moderate kappa agreement performance. The implication raised is that when ELISAs as diagnostics are used to detect Mpt in individual cattle, positive reaction by either ELISA should be interpreted as serologically Mpt positive due to presumed low sensitivity of ELISAs and their test agreement being less than 100%.

진단검사의 특성 평가를 위한 Receiver Operating Characteristic (ROC) 곡선의 활용 (Application of Receiver Operating Characteristic (ROC) Curve for Evaluation of Diagnostic Test Performance)

  • 박선일;오태호
    • 한국임상수의학회지
    • /
    • 제33권2호
    • /
    • pp.97-101
    • /
    • 2016
  • In the field of clinical medicine, diagnostic accuracy studies refer to the degree of agreement between the index test and the reference standard for the discriminatory ability to identify a target disorder of interest in a patient. The receiver operating characteristic (ROC) curve offers a graphical display the trade-off between sensitivity and specificity at each cutoff for a diagnostic test and is useful in assigning the best cutoff for clinical use. In this end, the ROC curve analysis is a useful tool for estimating and comparing the accuracy of competing diagnostic tests. This paper reviews briefly the measures of diagnostic accuracy such as sensitivity, specificity, and area under the ROC curve (AUC) that is a summary measure for diagnostic accuracy across the spectrum of test results. In addition, the methods of creating an ROC curve in single diagnostic test with five-category discrete scale for disease classification from healthy individuals, meaningful interpretation of the AUC, and the applications of ROC methodology in clinical medicine to determine the optimal cutoff values have been discussed using a hypothetical example as an illustration.

신경모세포종에서 $^{18}F-FDG$ PET의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET in Neuroblastoma)

  • 팽진철
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.134-136
    • /
    • 2008
  • Neuroblastoma is the most common extracranial solid tumor in children. In diagnostic assessment of neuroblastoma, $^{18}F-FDG$ PET has been reported to have high diagnostic performance, especially, very high sensitivity in staging, restaging, and assessment of therapeutic efficacy. In comparison with conventional diagnostic imaging modalities including a, bone scan, and MIBG scan, $^{18}F-FDG$ PET showed better diagnostic performance. According to clinical research data hitherto, $^{18}F-FDG$ PET is expected to be an effective diagnostic tool in the management of neuroblastoma.

가공 배전선로 진단시스템을 위한 최적 센서 개발 (Development of Optimal Sensor for Diagnostic System in Overhead Distribution Power Lines)

  • 이경섭
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.670-675
    • /
    • 2015
  • Degradation diagnosis of cable is one of major issues for operation and maintenance in overhead distribution power lines. The diagnostic system for overhead power lines is composed of three parts in functional aspect - a travelling unit, a sensing unit and a communication unit. Among them, sensor detects the defects such as corrosion and disconnecting of power lines. Performance of sensor is very important, and besides, the size and structure of sensor is restricted for installation to small and lightweight diagnostic system. This paper suggests an optimal eddy current sensor best suit for small and lightweight diagnostic system in consideration of detecting performance, size and ease of installation and so on. Proposed sensor has been designed by Drum core structure and can be applied to the all domestic overhead power lines regardless of the cross-sectional areas. Also, it is showed that results of mock environmental test are satisfied.

진단검사의 특성 추정을 위한 표본크기 (Sample Size Requirements in Diagnostic Test Performance Studies)

  • 박선일;오태호
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.73-77
    • /
    • 2015
  • There has been increasing attention on sample size requirements in peer reviewed medical literatures. Accordingly, a statistically-valid sample size determination has been described for a variety of medical situations including diagnostic test accuracy studies. If the sample is too small, the estimate is too inaccurate to be useful. On the other hand, a very large sample size would yield the estimate with more accurate than required but may be costly and inefficient. Choosing the optimal sample size depends on statistical considerations, such as the desired precision, statistical power, confidence level and prevalence of disease, and non-statistical considerations, such as resources, cost and sample availability. In a previous paper (J Vet Clin 2012; 29: 68-77) we briefly described the statistical theory behind sample size calculations and provided practical methods of calculating sample size in different situations for different research purposes. This review describes how to calculate sample sizes when assessing diagnostic test performance such as sensitivity and specificity alone. Also included in this paper are tables and formulae to help researchers for designing diagnostic test studies and calculating sample size in studies evaluating test performance. For complex studies clinicians are encouraged to consult a statistician to help in the design and analysis for an accurate determination of the sample size.

위 조직 생검 시료의 Helicobacter pylori 균 검출에 사용되는 진단검사의 특성을 추정하기 위한 비선형 모형의 응용 (Diagnostic Performance for Detection of Hezicobacter Pyzori Infection in Gastric Biopsy Specimens with No Gold Test: Non-linear Regression Approach)

  • Pak, Son-Il;Kim, Doo
    • 한국임상수의학회지
    • /
    • 제20권1호
    • /
    • pp.7-11
    • /
    • 2003
  • 감염된 환축을 찾는 진단과정에 완벽하지 못한 진단검사를 사용하는 경우 진단검사 결과는 흔히 왜곡되어 나타난다. 본 연구에서 저자는 Helicobacter pylori 감염을 진단하는데 사용되는 urease 검사, PCR 검사 및 조직학적인 검사법을 단독으로 사용하는 경우와 병행하여 사용하는 상황으로 구분하여 각각 진단적 특성을 평가하였다. 비선형 회귀모형 분석결과 민감도, 특이도, 양성우도비 및 음성우도비는 urease 검사법의 경우 99.9%, 99.9%, 99.9%, 99.6%, PCR 검사의 경우 88.6%, 99.9%, 99.9%, 70.5%, 조직검사법의 경우 78.3%, 97%, 78.3%, 97%fh 나타났다. 예측도는 유병율의 변화에 따라 다양한 값을 보였으며 Helicobacter pylori 감염의 유병율이 35% 이상일 때 조직 검사상 양성결과는 90% 이상의 일치도를 보였고, 유병율이 25% 미만일 때 조직 검사상 음성결과는 90% 이상의 일치도를 보였다. 본 연구결과 임상에서 감염된 개체를 스크리닝하는 목적으로 세가지 진단검사를 병행하는 것은 실질적인 이익이 없으며 단독검사로서 urease 검사와 PCR 검사가 가장 적합한 것으로 나타났다.