• Title/Summary/Keyword: Diagnostic monitor

Search Result 151, Processing Time 0.027 seconds

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Visual detection of porcine circovirus 2 by loop-mediated isothermal amplification (LAMP) with hydroxynaphthol blue dye (육안 판독 등온증폭법을 이용한 돼지 써코바이러스 2형 신속 진단법)

  • Kong, Ho-Chul;Kim, Eun-Mi;Jeon, Hyo-Sung;Kim, Ji-Jung;Kim, Hee-Jung;Park, Yu-Ri;Kang, Dae-Young;Kim, Young-Hwa;Park, Jun-Cheol;Lee, Chang-hee;Yeo, Sang-Geon;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.3
    • /
    • pp.145-153
    • /
    • 2015
  • In this study, we developed a loop-mediated isothermal amplification (LAMP) with hydroxynaphtol blue dye (HNB) for rapid and direct visual detection of porcine circovirus 2 DNA with high sensitivity and specificity. The LAMP was completed in 40 min at $63^{\circ}C$, and the results of the LAMP can be confirmed by naked eye without any detection process. The sensitivity of the LAMP was 10-fold higher than that of the commercial PCR (cPCR) and real time PCR (rPCR) previously reported. In clinical application, the PCV2 detection rate of the LAMP was the same on porcine tissue samples (75.0%, 36/48) between porcine blood samples (75.0%, 39/52). The PCV2 detection rate (75.0%) of LAMP was higher than those of the cPCR and rPCR (67.3%, 35/52) in blood samples. In conclusion, the LAMP developed in the study could be an useful alternative method for the detection of PCV2 in the swine disease diagnostic laboratories.

Development of Concrete Sensory Information for Patients Undergoing Cardiac Catheterization (심도자 검사 환자를 위한 구체적 감각 정보의 개발)

  • 김조자;김화순
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.2
    • /
    • pp.433-443
    • /
    • 1997
  • Cardiac catheterization is a diagnostic procedure which is intrusive and anxiety provoking. Patient education and information offer have been suggested as effective nursing interventions to reduce patients' anxiety and stress. Main objectives of this study are : 1) to develop concrete objective information for patients undergoing cardiac catheterization : 2) to analyze the types of information included in the newly developed concrete objective information. The subjects of this study are 11 patients who were admitted to the CCU of a general hospital in Seoul. The subjects were provided with preparatory information about cardiac catheterization by using interview and a booklet. After the procedure, the subjects were asked to describe additional information which they suggest to be added into the booklet and the physical sensations felt during the procedure. The results of the study are summarized as follows : Most subjects were satisfied with the preparatory information that was provided by interview and the booklet before the procedure. But patients suggested several problems related to the content of the booklet. First, they reported difficulty to differentiate the terms -coronary angio gram and cardiac catheterization. Also, some patients expressed that they feared after reading the information about the incision of inguinal area. Subjects responded that the information about the direct process of the test did not reduce their anxiety and the information was not detail enough. Next, most subjects would want to know about the monitor and the sound from monitor. They said that they could not hear instructions from doctor or nurse during the procedure due to tension. Considering above response results, the need for more effective way to provide information, like visual and auditory information through video tape for giving information is suggested. Sensations related to the procedure were the smell coming from sterilization of inguinal area, stinging pain in groin when the doctor inserts a needle into artery, and the sensation of pressure and moving of vessels surrounding neck when the catheter was inserted and visualized on fluoroscopy. Besides, subject reported hot sensation and burning feeling in face and chest area, and nausea when dye is injected by hand. In the analysis of information content, there was 79% agreement on the actual units of analysis that were coded. In the analysis of type of information, procedural information was 60.4%. Concrete objective information was 28.1%. and other information was 11.5%. Agreement of the coders in categorizing the units of information was determined by using Cohen's kappa which corrects for chance agreement. Cohen's kappa was .84.

  • PDF

Pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of foot-and-mouth disease virus (구제역바이러스 신속진단을 위한 pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) 진단법)

  • Lim, Da-Rae;Park, Yu-Ri;Park, Sun-Young;Kim, Hye-Ryung;Park, Min-Ji;Ku, Bok-Kyung;Nah, Jin-Ju;Ryoo, So-Yoon;Wee, Sung-Hwan;Jeon, Hyo-Sung;Kim, Ji-Jeong;Jeon, Bo-Young;Lee, Hyeong-Woo;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.1
    • /
    • pp.29-39
    • /
    • 2018
  • In this study, we developed a sensitive and specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid visual detection of foot-and-mouth disease virus (FMDV) circulated in Korea. The RT-LAMP was completed in 40 min at $62^{\circ}C$ and the results of the assay were directly detected by naked eye without any detection process. The assay specifically amplified all 7 serotypes of FMDV RNAs but not amplified other viral and cellular nucleic acids. The sensitivity of the RT-LAMP was $10^2$, $10^3$ and $10^3TCID_{50}/mL$ for serotype O, A and Asia 1 FMDV, respectively, which was comparable to conventional reverse transcription polymerase chain reaction (RT-PCR) and relatively lower than that of real time quantitative RT-PCR (qRT-PCR). Clinical evaluation of the RT-LAMP using different serotypes of Korean and foreign FMDV strains showed a 100% (35/35) agreement with the results of the RT-PCR and qRT-PCR. These results indicated that RT-LAMP assay developed in this study could be a valuable diagnostic method for FMDV monitoring and surveillance.

Research on Communication and The Operating of Server System for Vehicle Diagnosis and Monitoring (차량진단 및 모니터링을 위한 통신과 서버시스템 운용에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.6
    • /
    • pp.41-50
    • /
    • 2011
  • This article is concerned with the technology to provide car driver the car's status which are composed of car trouble code in car engine and many sensors. In addition, it installs vehicle diagnostic programs on wireless communication's portable device, for example, Smart phone, PDA, PMP, UMPC. As a result, this is to provide car manager with many information of car sensors when we go to car maintenance. it can monitor relevant information on vehicle by portable device in real time, alert drivers with specific messages and also enable them to address abnormalities immediately. Moreover, the technology could help the drivers who perhaps don't know very well about their vehicles to drive safely and economically as well; the reason is because the whole system is composed of just Vehicle-information collecting device and personal wireless communication's portables and transfers the relating data to server computers through wireless network in order to handle information on vehicles. This technology make us monitor vehicle's running, failure and disorder by using wireless communication's portable device. Finally, this study system is composed of a lot of application to display us the car's status which get car's inner sensor information while driving a car.

Research on Vehicle Diagnostic and Monitoring technology Using WiBro Portable Device (와이브로 휴대기기를 사용한 차량진단 및 모니터링 기술에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul;Ahn, Yong-Beom
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.10
    • /
    • pp.17-26
    • /
    • 2010
  • This is concerned with the technology to monitor the vehicle operation, failure and disorder by using WiBro portable device. More precisely, the technology makes it possible that the information collection device is connected to both ECU(Electronic Control Unit) which is the device for controlling engine, transmission, brake, air-bag, etc that are connected to in-vehicle network and OBD-II connector that is for data collection from various sensors. In addition, with a WiBro portable device (cell phone, PDA, PMP, UMPC, etc). equipped with a vehicle diagnostic programs, information for operation, failure and malfunction can be obtained and analyzed in real-time, and alarm is alerted when the vehicle is in abnormal status, which makes the early reactions to the status. Furthermore, the collected data can be sent through WiBro network to the server managed by the company specialized in managing the vehicles, thus the technology could help the drivers who have less knowledge about their auto-vehicles have safe and economic driving. There is always a possibility of malfunction due to various types of noise that are caused by wring-harness when the device is wired-connected. In this research, in order to overcome this problem, we propose a system configuration that can do monitoring and diagnosis with a device for collecting data from vehicle and a personal WiBro device. Also, we performed research on data acquisition and interlock for the system defined by the definition for information and data sharing platform.

Sequential 1H MR Spectroscopy(MRS) Studies of Kaolin-Induced Hydrocephalic Cat Brain (Kaolin 유발 고양이 수두증 모델에서 양자 자기공명 분광상의 경시적 변화)

  • Kim, Myung Jin;Hwang, Sung Kyoo;Hwang, Jeong Hyun;Chang, Yongmin;Kim, Yong Sun;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1421-1428
    • /
    • 2000
  • Objectives : The aim of this study is to evaluate the sequential metabolic changes in experimental hydrocephalus and the clinical applicability to the diagnosis and prognosis of hydrocephalus using proton MR spectroscopy. Methods : Hydrocephalus was experimentally induced in 30 cats(2-3kg body weight) by injecting 1ml of sterile kaolin suspension(250mg/ml) into the cisterna magna. Proton MRS was performed with a 1.5 T MRI/MRS unit (Vision Plus, Siemens) at pre-treatment and at 1, 3, 7, 14, 21, and 28 days after the kaolin injection. PRESS(TR/TE=1500/270msec) technique was employed. The major metabolites which include N-acetyl aspartate (NAA), creatine(Cr), choline(Cho), and lactate(Lac) were quantitatively analyzed and the relative concentrations ratios were evaluated. Multislice $T_2$-weighted images were also obtained using fast spin echo sequence(TR/TE= 2500/96msec) to monitor the morphologic changes along with progression of hydrocephalus. Results : Hydrocephalus was successfully induced in all 30 cats. Twenty five cats died within 3 days and one at the end of the second week. In all animals, the NAA/Cr ratios initially decreased during the acute stage. In 4 surviving cats, the NAA/Cr ratios initially decreased during the acute stage(<14 days) and then gradually increased to the prekaolin level as follows : pre-kaolin($1.49{\pm}0.04$), day 1($1.11{\pm}0.07$), day 7($1.17{\pm}0.04$), day 14($1.40{\pm}0.03$), day 21 ($1.46{\pm}0.06$), day 28($1.43{\pm}0.03$). These levels were relatively well correlated with the symptomatologic improvement. Lactate peak, which reflects the evidence of ischemia, did not appear throughout the entire period except in one case which expired at the end of the second week. Conclusions : The NAA/Cr ratio of the sequential proton MRS in kaolin-induced hydrocephalic cats reflects a metabolic aspect of the hydrocephalus at each stage. A decreased NAA level at the early stage is from both neuronal and axonal damage which may provide diagnostic information in the acute stage of hydrocephalus. In addition, the initial fall of NAA/Cr ratio and recovery in the late stage, when no lactate peak emerges, may suggest that the main insult of the parenchyma is not to the neuron itself but to the axon, which may be related to a good prognosis. However, emergence of the lactate peak and unrecoverable NAA/Cr at the end of the acute phase may be a poor prognostic factor. In the chronic stage, recovery of NAA/Cr ratio may provide a diagnostic clue for the differentiation between hydrocephalus and cortical atrophy.

  • PDF

Development of PCR-Based Sequence Characterized DNA Markers for the Identification and Detection, Genetic Diversity of Didymella bryoniae with Random Amplified polymorphic DNA(RAPD)

  • Kyo, Seo-Il;Shim, Chang-Ki;Kim, Dong-Kil;Baep, Dong-Won;Lee, Seon-Chul;Kim, Hee-Kyu
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.130-130
    • /
    • 2003
  • Gummy stem blight pathogen is very difficult not only to monitor the inoculum levels prior to host infection, and also it is destructive and hard to control in field condition. We have applied RAPD technique to elucidate the genetic diversity of the genomic DNA of Didymella bryoniae and also to generate specific diagnostic DNA probe useful for identification and detection. The 40 primers produced clear bands consistently from the genomic DNA of twenty isolates of Didymella bryoniae, and two hundred seventy-three amplified fragments were produced with 40 primers. The combined data from 273 bands was analyzed by a cluster analysis using UPGMA method with an arithmetic average program of NTSYS-PC (Version 1.80) to generate a dendrogram. At the distance level of 0.7, two major RAPD groups were differentiated among 20 strains. RAPD group (RG) I included 8 isolates from watermelon except one isolate from melon. RAPD group (RG) IV included 12 isolates from squash, cucumber, watermelon and melon.. In amplification experiment with SCAR specific primer RG1F-RG1R resulted in a single band of 650bp fragment only for 8 isolates out of 20 isolates that should be designated as RAPD Group 1. However, same set of experiment done with RGIIF-RGIIR did not result in any amplified product.. Our attempts to detect intraspecific diversity of ITS region of rDNA by amplifying ITS region and 17s rDNA region for 20 isolates and restriction digestion of amplified fragment with 12 enzymes did not reveal polymorphic band. In order to develop RAPD markers for RGIV specific primer, a candidate PCR fragment( ≒1.4kb) was purified and Southern hybridized to the amplified fragment RGIV isolates. This promising candidate probe recognized only RGIV isolates

  • PDF

Estimation of Blood Pressure Diagnostic Methods by using the Four Elements Blood Pressure Model Simulating Aortic Wave Reflection (대동맥 반사파를 재현한 4 element 대동맥 혈압 모델을 이용한 혈압 기반 진단 기술의 평가)

  • Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.183-190
    • /
    • 2015
  • Invasive blood pressure (IBP) is measured for the patient's real time arterial pressure (ABP) to monitor the critical abrupt disorders of the cardiovascular system. It can be used for the estimation of cardiac output and the opening and closing time detection of the aortic valve. Although the unexplained inflections on ABP make it difficult to find the mathematical relations with other cardiovascular parameters, the estimations based on ABP for other data have been accepted as useful methods as they had been verified with the statistical results among vast patient data. Previous windkessel models were composed with systemic resistance and vascular compliance and they were successful at explaining the average systolic and diastolic values of ABP simply. Although it is well-known that the blood pressure reflection from peripheral arteries causes complex inflection on ABP, previous models do not contain any elements of the reflections because of the complexity of peripheral arteries' shapes. In this study, to simulate a reflection wave of blood pressure, a new mathematical model was designed with four elements that were the impedance of aorta, the compliance of aortic arch, the peripheral resistance, and the compliance of peripheral arteries. The parameters of the new model were adjusted to have three types of arterial blood pressure waveform that were measured from a patient. It was used to find the relations between the inflections and other cardiovascular parameters such as the opening-closing time of aortic valve and the cardiac output. It showed that the blood pressure reflection can bring wide range errors to the closing time of aortic valve and cardiac output with the conventional estimation based on ABP and that the changes of one-stroke volumes can be easily detected with previous estimation while the changes of heart rate can bring some error caused by unexpected reflections.

Probabilistic-based damage identification based on error functions with an autofocusing feature

  • Gorgin, Rahim;Ma, Yunlong;Wu, Zhanjun;Gao, Dongyue;Wang, Yishou
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1121-1137
    • /
    • 2015
  • This study presents probabilistic-based damage identification technique for highlighting damage in metallic structures. This technique utilizes distributed piezoelectric transducers to generate and monitor the ultrasonic Lamb wave with narrowband frequency. Diagnostic signals were used to define the scatter signals of different paths. The energy of scatter signals till different times were calculated by taking root mean square of the scatter signals. For each pair of parallel paths an error function based on the energy of scatter signals is introduced. The resultant error function then is used to estimate the probability of the presence of damage in the monitoring area. The presented method with an autofocusing feature is applied to aluminum plates for method verification. The results identified using both simulation and experimental Lamb wave signals at different central frequencies agreed well with the actual situations, demonstrating the potential of the presented algorithm for identification of damage in metallic structures. An obvious merit of the presented technique is that in addition to damages located inside the region between transducers; those who are outside this region can also be monitored without any interpretation of signals. This novelty qualifies this method for online structural health monitoring.