• 제목/요약/키워드: Diagnostic method

검색결과 2,473건 처리시간 0.032초

ELM 기반의 지능형 알고리즘과 퍼지 소속함수를 이용한 유입변압기 고장진단 기법 (Diagnosis Method for Power Transformer using Intelligent Algorithm based on ELM and Fuzzy Membership Function)

  • 임재윤;이대종;지평식
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.194-199
    • /
    • 2017
  • Power transformers are an important factor for power transmission and cause fatal losses if faults occur. Various diagnostic methods have been applied to predict the failure and to identify the cause of the failure. Typical diagnostic methods include the IEC diagnostic method, the Duval diagnostic method, the Rogers diagnostic method, and the Doernenburg diagnostic method using the ratio of the main gas. However, each diagnostic method has a disadvantage in that it can't diagnose the state of the power transformer unless the gas ratio is within the defined range. In order to solve these problems, we propose a diagnosis method using ELM based intelligent algorithm and fuzzy membership function. The final diagnosis is performed by multiplying the result of diagnosis in the four diagnostic methods (IEC, Duval, Rogers, and Doernenburg) by the fuzzy membership values. To show its effectiveness, the proposed fault diagnostic system has been intensively tested with the dissolved gases acquired from various power transformers.

유우(乳牛)의 조기임신진단(早期姙娠診斷)에 관한 연구(硏究) (Studies on Early Pregnancy Diagnosis in Dairy Cows)

  • 김교준;김상근
    • 대한수의학회지
    • /
    • 제20권2호
    • /
    • pp.135-141
    • /
    • 1980
  • This experiment was carried out to investigate of the early pregnancy diagnosis by finger pressure method, mucus smear method and rectal palpation method in 169 heads of pregnant dairy cow. 1. Pregnancy diagnostic rate of previous, middle and late period of pregnancy by finger pressure methods were 87.3%, 82.0% and 70% respectively. 2. Pregnancy diagnostic rate of previous, middle and late period of pregnancy by mucus smear methods were 83.1%. 94.9% and 95.0% respectively. 3. Pregnancy diagnostic rate of previous, middle and later period of pregnancy by rectal palpation methods were 83.1%, 96.1% and 100% respectively. 4. Pregnancy diagnostic rate of early pregnancy by finger pressure method, mucus smear method and rectal palpation method were 86.7%, 86.8% and 66% respectively. 5. Accordingly, finger pressure method in pregnancy diagnosis is thought to be recommendable because this early diagnostic means are simple with accurate results.

  • PDF

투시조영검사에서 동영상의 컴퓨터 동시캡쳐방식과 적응 예 (Syncronous Computer-Capturing Method of Dynamic Images on Fluoroscopic Studies and Applications)

  • 장동혁;이경록;장지원;김대중;서정환;박영순
    • 대한방사선협회지
    • /
    • 제29권1호
    • /
    • pp.25-30
    • /
    • 2003
  • Purpose : The purpose of this study is to present computer-capturing method of dynamic images on fluoroscopic studies, as a substitution for video-recording method, and to help the quantitative analysis of the dynamic studies. Materials and Methods: Compu

  • PDF

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.

ECU 진단통신을 위한 표준 진단통신 모듈 연구 (A Study of Standard Diagnostic Communications Modules for ECU Diagnostic Communications)

  • 장문수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.507-509
    • /
    • 2022
  • 자동차 내부 진단 데이터를 수집하기 위해서는 다양한 자동차 부품에 포함되어 있는 ECU(Electronic Control Unit)의 진단데이터를 수집하여야 한다. ECU의 진단데이터를 수집하기 위해서는 진단통신을 활용할 수 있다. 본 논문에서는 표준 진단 통신을 통해 ECU의 기능에 따른 진단데이터를 수집하는 방법과 진단통신 모듈에 대해서 분석하였다. 많은 자동차 제조사가 사용하는 자동차 전장 표준인 AUTOSAR의 표준 모듈 중에서 진단 통신 모듈에 대해서 연구하였으며, 진단데이터 처리가 ECU를 통해 처리되는 과정에 대해서 연구하였다.

  • PDF

교수방법의 효율화를 위한 웹 기반 진단평가 시스템 설계 및 구현 (Design and Implementation of a Web-based Diagnostic Evaluation System for Efficient Teaching Method)

  • 유선경;이미정
    • 컴퓨터교육학회논문지
    • /
    • 제6권3호
    • /
    • pp.197-205
    • /
    • 2003
  • 효과적인 교수활동을 위해서는 교수자가 학습자의 현 수준을 정확히 파악해야 한다. 학습자의 수준 파악을 위해서는 일반적으로 진단평가를 활용한다. 그러나 시간상의 제약으로 인해 교수자가 필요로 하는 모든 경우에 학습자의 수준 파악을 위한 진단평가를 실시하기는 어렵다. 이에 본 논문에서는 교수자 교수방법의 효율화를 위한 웹 기반 진단평가시스템을 제안한다. 제안하는 시스템에서는 교수자가 웹을 통해 원하는 평가문제를 수시로 입력하는 것이 가능하며 학습자는 자신의 수강과목의 일정에 따라 시공간 제약 없이 개별적으로 온라인 진단평가를 수행할 수 있다. 또한 제안하는 시스템에서는 각 학습자의 평가결과를 자동으로 처리하여 교수자가 학습자의 현재 수준을 분석하고 교육 수준을 결정할 수 있는 다양한 통계 자료를 제시해준다.

  • PDF

The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

  • Jongmin J. Lee;Phillip J. Tirman;Yongmin Chang;Hun-Kyu Ryeom;Sang-Kwon Lee;Yong-Sun Kim;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.142-151
    • /
    • 2000
  • Objective: To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods: Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results: Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion: The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method.

  • PDF

"상한론(傷寒論)" 맥진(脈診)의 원리 (The fundamental principles of pulse feeling(脈診) of "Sanghanlon(傷寒論)")

  • 정창현;장우창
    • 대한한의학원전학회지
    • /
    • 제20권1호
    • /
    • pp.137-149
    • /
    • 2007
  • Diagnostic method by taking pulse is generally accepted as a clinical diagnosis of today. Theoretical foundation of the method was laid by "Hwangjenaegyeong" and "Nangyeong". Since then, it was quoted by "Sanghallon" and systematically applied to diagnoses by making a diagnosis in the light of pulse condition and symptoms observed so that the original form of the method was shaped thereby. And therefore, theoretical significance of diagnostic method by taking pulse was drawn in this paper to define the theory of pulse feeling. Furthermore, this paper is corroborative of that the purpose of diagnostic method by taking pulse is to diagnose pyo-lee and jang-bu; wind-cold-warmth-heat; and deficiency and excess of gi and blood as well as substantially prove it with the texts of "Sanghallon".

  • PDF

PDA 기반의 차량 진단신호의 원격 계측 (Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF