• 제목/요약/키워드: Diagnostic imaging system

검색결과 340건 처리시간 0.029초

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

초음파 영상진단장치 (A Diagnostic Ultrasound Imaging System)

  • 이승우
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

Magnetic Resonance Imaging Meets Fiber Optics: a Brief Investigation of Multimodal Studies on Fiber Optics-Based Diagnostic / Therapeutic Techniques and Magnetic Resonance Imaging

  • Choi, Jong-ryul;Oh, Sung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.218-228
    • /
    • 2021
  • Due to their high degree of freedom to transfer and acquire light, fiber optics can be used in the presence of strong magnetic fields. Hence, optical sensing and imaging based on fiber optics can be integrated with magnetic resonance imaging (MRI) diagnostic systems to acquire valuable information on biological tissues and organs based on a magnetic field. In this article, we explored the combination of MRI and optical sensing/imaging techniques by classifying them into the following topics: 1) functional near-infrared spectroscopy with functional MRI for brain studies and brain disease diagnoses, 2) integration of fiber-optic molecular imaging and optogenetic stimulation with MRI, and 3) optical therapeutic applications with an MRI guidance system. Through these investigations, we believe that a combination of MRI and optical sensing/imaging techniques can be employed as both research methods for multidisciplinary studies and clinical diagnostic/therapeutic devices.

고주파 열치료(Rodiofrequency ablotion)에 이용되는 내부 냉각 전극(Internally cooled needle electrodes)를 이용한 간 소작법의 유용성 실험 (An Experimental Study on Hepatic Ablation using an Internally Cooled Needle Electrodes in Radiofrequency Ablation)

  • 한정환;안정현;박원식
    • 대한방사선협회지
    • /
    • 제30권1호
    • /
    • pp.58-62
    • /
    • 2004
  • The purpose of this study was to determine the factors influencing on the size of Radiofrequency ablation using an internally cooled needle electrodes in cattle liver. Ablation procedures involved the use of cool-tip RF system generator and internally coo

  • PDF

영상진단 수가 변화가 의료공급자 진료행태에 미치는 영향: 전산화단층영상진단 검사건수를 중심으로 (The Impact of Diagnostic Imaging Fee Changes to Medical Provider Behavior: Focused on the Number of Exams of Computed Tomograph)

  • 조수진;김동환;윤은지
    • 보건행정학회지
    • /
    • 제28권2호
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Diagnostic imaging fee had been reduced in May 2011, but it was recovered after 6 months because of strong opposition of medical providers. This study aimed to analyze the behavior of medical providers according to fee changes. Methods: The National Health Insurance claims data between November 2010 and December 2012 were used. The number of exams per computed tomography was analyzed to verify that the fee changes increased or decreased the number of exams. Multivariate regression model were applied. Results: The monthly number of exams increased by 92.5% after fee reduction, so the diagnostic imaging spending were remained before it. But medical provider decreased the number of exams after fee return. After adjusting characteristic of hospitals, fee reduction increased the monthly number of exams by 48.0% in a regression model. Regardless type of hospitals and severity of disease, the monthly number of exams increased during period of fee reduction. The number of exams in large-scaled hospitals (tertiary and general hospital) were increased more than those of small-scaled hospitals. Conclusion: Fee-reduction increased unnecessary diagnostic exams under the fee-for-service system. It is needed to define appropriate exam and change reimbursement system on the basis of guideline.

First Multi-Detector Computed Tomography Evidence of Transcatheter Pacing System Migration and Embolization into the Pulmonary Vasculature

  • Valente, Tullio;Bocchini, Giorgio;Bigazzi, Maurizio Cappelli;Muto, Massimo;Golino, Paolo;Sica, Giacomo
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.310-312
    • /
    • 2020
  • Transcatheter leadless pacemaker dislodgment is a rare and potentially fatal complication of leadless device implantation. We present the first case of multidetector computed tomography images of leadless pacemaker migration and embolization in the pulmonary middle lobe artery. The patient was managed by percutaneous retrieval of the dislodged device and re-implantation in the appropriate position.

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

진단용 영상장치에서 전자파 측정에 관한 고찰 (A Study on the Electromagnetic Wave Measurement in Diagnostic Imaging Equipment)

  • 어윤기
    • 대한디지털의료영상학회논문지
    • /
    • 제7권1호
    • /
    • pp.39-44
    • /
    • 2005
  • Purpose of this research is that if Radiographer has focused on Radiation exposure research until now, he should realize that always exposed by Electro Magnetic Wave at given working environment And also, another purpose is that to minimize damage with measuring Electro Magnetic Wave which is happened area and distance of Radiation Control System and High Voltage Equipment, check occurrence rate and minimize damage from it.

  • PDF