• 제목/요약/키워드: Diagnostic assessment

검색결과 749건 처리시간 0.026초

한국어판 Cornell Assessment of Pediatric Delirium 소아 섬망 사정 도구의 검증 (The Reliability and Validity of the Korean Version of the Cornell Assessment of Pediatric Delirium)

  • 남송이;박기영;최수정
    • 임상간호연구
    • /
    • 제26권2호
    • /
    • pp.254-264
    • /
    • 2020
  • Purpose: This study was to examine the reliability and validity of the Korean version of the Cornell Assessment of Pediatric Delirium (CAPD). Methods: For testing the reliability of the Korean version of the CAPD, this study calculated the internal consistency (Cronbach's α) and the Interrater Correlation Coefficient (ICC) by comparing the independent assessment results of three nurses in Pediatric Intensive Care Unit (PICU). For testing the validity of the Korean version of the CAPD, the assessment result of the Korean version of the CAPD compared with that of the Diagnostic and Statistical Manual of Mental Disorders V (DSM-V). Receiver Operating Characteristics (ROC) analysis was used for measuring sensitivity and specificity. Results: Overall interrater reliability of the Korean version of the CAPD, ICC was .98 (95% CI .96~.99). Cronbach's α was .91 for eight items. The concordance between the Korean version of the CAPD and psychiatrist's diagnosis was 90.0%. When the Korean version of the CAPD has the cut point of 9, sensitivity was 93.8%, and specificity was 75.0%. The area under the curve indicated by the ROC analysis was .88. Conclusion: The Korean version of the CAPD showed good reliability and validity. This tool will be useful for pediatric delirium screening and management in Korean PICU.

단일맹검시험을 통한 대황(大黃) 상용량(常用量)의 독성작용 평가 (Evaluation on Toxicity of Habitual dose of Extract of Rheum Palmatum through Single Blinded Pilot Study)

  • 권혁;지규용;엄현섭
    • 동의생리병리학회지
    • /
    • 제24권3호
    • /
    • pp.390-400
    • /
    • 2010
  • This study is aimed to test physiological and hematological actions of Rheum palmatum through clinical pilot study optimized for usual oriental medicine prescription. Thirty-one cases were finally collected and the sample extract 100 $m{\ell}$ of Rheum palmatum (ERP) was administered two times in a day during 3 days and checked with blood CBC test, urinalysis, liver function test, abdominal X-ray as well as general diagnostic process of oriental medicine; pattern identification, assessment of shapes and constitution. The total toxic effective rate of ERP was 9.68% in 3 cases of the whole in case of consistent uneasy state in the subjective symptomatic assessment and aggravation of blood and urine examination. The relevant diagnostic factors were so-eum constitution and essence type subject, carapaces species, lung type in the aspect of Jisan shape theory. On the other hand, the positive effective rate of ERP was 29.03% manifesting improvement of vital signs or present illness and no abnormal changes of blood chemistry and urinalysis and simple abdomen radiology. The relevant diagnostic factors were tae-eum constitution, energy type subject, aves species, heart and liver type in Jisan's shape theory. And the other cases were manifesting no specific change through the administration of ERP. The ratio of the numbers of decrease and increase was 44:5 in the tenderness and hardness of abdominal palpation. But if the pattern identification doesn't comply with the aim of rhubarb application despite of constipation and abdominal pain, the tendeness and biochemical report was shown in abnormal change. The mean number of diarrhea by ERP was $16.77{\pm}6.95$ during 3 days after administration, and the frequent areas of abdominal pain were lower>middle>upper in order, and it meant the target site of ERP too. Besides, the toxic reaction against ERP was expressed highly in case of decrease in blood cell count and hemoglobin, hematocrit having blood deficiency syndrome. Likewise, the toxicity of ERP was influenced by pattern identification manifesting present disease condition and diagnostic factors of four constitutions, Jisan's shape theory collaterally. In conclusion, evaluation of herbal toxicity in order for using as a clinical guideline, various diagnostic pattern information and shape features like the above should be studied together with other pharmacologic toxicology test for the future.

진단X선에 의한 성인의 진단행위별 유효선량평가 (Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult)

  • 김우란;이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제27권3호
    • /
    • pp.155-164
    • /
    • 2002
  • 몬테칼로 모사를 통해 여러 가지 진단X선 검사를 받는 성인의 유효선량을 평가하는 방법체계를 구축하였다. 피사체 인형팬텀으로서 MIRD5 남성 팬텀과 ORNL 여성팬텀이 이용되었고 사용 X선 스펙트럼은 SPEC78 코드로 생산하였다. 같은 진단절차에 대해 NRPB 평가결과와 비교함으로써 계산체계를 검증하였다. 계산체계를 이용하여 흉곽, 복부, 두부 및 척추의 진단에서 AP, PA, LLAT 및 RLAT 방향으로 입사하는 X선에 대한 장기 등가선량과 유효선량을 평가하였으며 가장 보편적인 흉곽 PA와 복부 AP의 경우 유효선량이 각각 0.029mSv와 0.44mSv로 나타났다. 흉곽 PA 1회 촬영 시 피폭하는 선량이 전통적 평가치인 0.3mSv(또는 30mrem)보다 매우 작게 나타나는 것은 진단방사선 기술의 발전뿐만 아니라 적용하는 선량개념의 차이에 기인하는 것으로서 여러 방사선 의료절차에 대한 집중적인 환자선량 평가의 필요성을 강조하는 것이다. 여기서 개발된 선량평가 체계는 CT 선량, 임부의 진단으로 인한 태아의 선량, 소아과 X선에 의한 선공 등 다른 방사선 의료절차에도 용이하게 응용될 수 있다.

Interactive learning in oral and maxillofacial radiology

  • Ramesh, Aruna;Ganguly, Rumpa
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.211-216
    • /
    • 2016
  • Purpose: The use of electronic tools in teaching is growing rapidly in all fields, and there are many options to choose from. We present one such platform, Learning Catalytics$^{TM}$ (LC) (Pearson, New York, NY, USA), which we utilized in our oral and maxillofacial radiology course for second-year dental students. Materials and Methods: The aim of our study was to assess the correlation between students' performance on course exams and self-assessment LC quizzes. The performance of 354 predoctoral dental students from 2 consecutive classes on the course exams and LC quizzes was assessed to identify correlations using the Spearman rank correlation test. The first class was given in-class LC quizzes that were graded for accuracy. The second class was given out-of-class quizzes that were treated as online self-assessment exercises. The grading in the self-assessment exercises was for participation only and not accuracy. All quizzes were scheduled 1-2 weeks before the course examinations. Results: A positive but weak correlation was found between the overall quiz scores and exam scores when the two classes were combined (P<0.0001). A positive but weak correlation was likewise found between students' performance on exams and on in-class LC quizzes (class of 2016) (P<0.0001) as well as on exams and online LC quizzes (class of 2017) (P<0.0001). Conclusion: It is not just the introduction of technological tools that impacts learning, but also their use in enabling an interactive learning environment. The LC platform provides an excellent technological tool for enhancing learning by improving bidirectional communication in a learning environment.

수족냉증 중증도 판단에 영향을 미칠 수 있는 요인 분석 (Analysis of Factors that Can Affect the Assessment of Severity of Cold Hypersensitivity in Hands and Feet)

  • 김진우;박경선;이창훈;장준복;이경섭;이진무
    • 대한한방부인과학회지
    • /
    • 제25권4호
    • /
    • pp.38-45
    • /
    • 2012
  • Purpose: The purpose of this study is to find the factors that can affect the assessment on severity of cold hypersensitivity on hands and feet by comparing the temperature distribution among the seasons, the scan time and the laboratory temperature. Methods: We compared the temperature distribution of the arms and legs, according to the season and scan time on the basis of the results of Digital Infrared Thermal Imaging(DITI) conducted on 178 women who visited the hospital in summer and winter. We evaluated the correlation between the laboratory temperature and temperature distribution of the arms and legs. Results: The temperature distribution of the arms and legs was significantly different between summer and winter. The temperature distribution of the arms and legs was not significantly different according to the scan time. There was no significant correlation between laboratory temperature and the temperature distribution of the arms and legs in summer and winter. Conclusions: The diagnostic criteria to assess the severity of cold hypersensitivity on hands and feet need to be changed according to the season. The scan time and the small variation($24^{\circ}C{\sim}27^{\circ}C$) of the laboratory temperature doesn't affect the assessment of severity of cold hypersensitivity.

Diagnostic keys of the overcoming risk factors and achieving predictable esthetics in anterior single implant

  • Choi, Geun-Bae;Yang, Jong-Sook
    • 대한심미치과학회지
    • /
    • 제16권2호
    • /
    • pp.7-18
    • /
    • 2007
  • There is now an increased demand for harmony between the peri-implant gingiva and adjacent dentition. In the event of a pending loss of a single tooth in the aesthetic zone with healthy periodontium, expectation for optimal gingival and prosthodontic aesthetics are often very high. Unfortunately, bone resorption is common following the removal of an anterior tooth, compromising the gingival tissue levels for the eventual implant restoration. Also, improper implant placement and inadequate osseous-gingival support potentially deleterious aesthetic result. The creation of an esthetic implant restoration with gingival architecture that harmonizes with the adjacent dentitionis formidable challenge. The predictability of the peri-implant esthetic outcome may ultimately be determined by the patient's own presenting anatomy rather than the clinician's ability to manage state-of-the-art procedures. To more accurately predict the peri-implant esthetic outcome before removing a failing tooth, a considering of diagnostic keys is essential. This presentation addresses the useful diagnostic keys that affect the predictability of peri-implant gingival aesthetics and the overcoming of the risk factors in anterior single-tooth replacement; it also describes a surgical and prosthodontic technique in achieving a long term successful esthetic outcome. Proper diagnosis and understanding of the biological and periodontal variables of failing dentition and their response to surgical and prosthodontic procedures are the essence of predictability. Using a smart protocol that alters the periodontium toward less risk and more favorable assessment of the diagnostic keys before implant placement will provide the most predictable esthetic outcome. Simple diagnostic keys suggested this presentation are useful method to evaluate the overcoming of the risk factors in anterior single implant restoration.

  • PDF

Value of Contrast-Enhanced Ultrasonography in the Differential Diagnosis of Enlarged Lymph Nodes: a Meta-Analysis of Diagnostic Accuracy Studies

  • Jin, Ya;He, Yu-Shuang;Zhang, Ming-Ming;Parajuly, Shyam Sundar;Chen, Shuang;Zhao, Hai-Na;Peng, Yu-Lan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권6호
    • /
    • pp.2361-2368
    • /
    • 2015
  • Objective: To evaluate the diagnostic accuracy of contrast-enhanced ultrasonography (CEUS) in differentiating between benign and malignant enlarged lymph nodes using meta-analysis. Materials and Methods: Pubmed, Embase, SCI and Cochrane databases were searched for studies (up to September 1, 2014) reporting the diagnostic performance of CEUS in discriminating between benign and malignant lymph nodes. Inclusion criteria were: prospective study; histopathology as the reference standard; and sufficient data to construct $2{\times}2$ contingency tables. Methodological quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Patient clinical characteristics, sensitivity and specificity were extracted. The summary receiver operating characteristic curve was used to examine the accuracy of CEUS. A meta-analysis was performed to evaluate the clinical utility in identification of benign and malignant lymph nodes. Sensitivity analysis was performed after omitting outliers identified in a bivariate boxplot and publication bias was assessed with Egger testing. Results: The pooled sensitivity, specificity and AUROC were 0.92 (95%CI, 0.85-0.96), 0.91 (95%CI, 0.82-0.95) and 0.97 (95%CI, 0.95-0.98), respectively. After omitting 3 outlier studies, heterogeneity decreased. Sensitivity analysis demonstrated no disproportionate influences of individual studies. Publication bias was not significant. Conclusions: CEUS is a promising diagnostic modality in differentiating between benign and malignant lymph nodes and can potentially reduce unnecessary fine-needle aspiration biopsies of benign nodes.

Are p53 Antibodies a Diagnostic Indicator for Patients with Oral Squamous Cell Carcinoma? Systematic Review and Meta-Analysis

  • Yang, Zhi-Cheng;Ling, Li;Xu, Zhi-Wei;Sui, Xiao-Dong;Feng, Shuang;Zhang, Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.109-115
    • /
    • 2016
  • Background: P53 has been reported to be involved with tumorigenesis and has also been implicated as a significant biomarker in oral squamous cell carcinoma(OSCC). However, the diagnostic value of p53 antibodies remains controversial; hence, we comprehensively and quantitatively assessed the potential in the present systematic review. Materials and Methods: A comprehensive search was performed using PubMed and Embase, up to October 31, 2014, without language restriction. Studies were assessed for quality using QUADAS (quality assessment of studies of diagnostic accuracy). The positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were pooled separately and compared with overall accuracy measures using diagnostic odds ratios (DORs) and symmetric summary receiver operating characteristic (SROC) curves. Results: Of 150 studies initially identified, 7 eligible regarding serum p53 antibodies met the inclusion criteria. Some 85.7% (6/7) were of relatively high quality (QUADAS $score{\geq}7$). The summary estimates for quantitative analysis of serum p53 antibody in the diagnosis of squamous cell carcinoma were: PLR 2.06 [95% confidence interval (CI) : 1.35-3.15], NLR 0.85 (95%CI: 0.80-0.90) and DOR 2.47 (95%CI: 1.49-4.12). Conclusions: This meta-analysis suggests that the use of s-p53-antibodies has potential diagnostic value with relatively high sensitivity and specificity for OSCC particularly with serum specimens for discrimination of OSCCs from healthy controls. However, its discrimination power is not perfect because of low sensitivity.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.