• Title/Summary/Keyword: Diagnostic agreement rate

Search Result 46, Processing Time 0.026 seconds

A Study for Diagnostic Agreement between Web-based Diagnosis Support System and Korean Medical Doctors' Diagnosis (웹기반 진단 보조 시스템의 진단 일치도 연구)

  • Seungyob Yi;Minji Kang;Hyun Jung Lim;WM Yang
    • Journal of Convergence Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • Objectives: This study aims to evaluate the clinical validity of the system by conducting a clinical study to assess the diagnostic agreement between the system and Korean medical doctors. Methods: This study was conducted from September 7, 2023, to December 7, 2023, across five Korean medicine institutions, involving 100 adult participants aged 20-64 who consented to participate. Participants first entered their symptoms into a web-based program, which utilized an AI-based algorithm to diagnose 36 types of pattern differentiation. Subsequently, Korean medical doctors conducted face-to-face diagnoses using the same 36 types. The diagnostic agreement between the system and the doctors' diagnoses was analyzed using descriptive statistical analysis, and the results were expressed as a percentage agreement. Results: Analysis of the diagnostic data from 100 participants revealed that the web-based diagnosis support system identified an average of 7.76±0.79 patterns per patient, while Korean medical doctors identified an average of 7.99±0.10 patterns per patient. The diagnostic agreement between the system and the doctors showed an average of 7.08±1.08 patterns per patient, with an overall diagnostic agreement rate of 88.57±13.31%. Conclusion: This study developed a web-based diagnosis support system for traditional Korean medicine and evaluated its clinical validity by assessing diagnostic agreement. Comparing the diagnoses of the system with those of Korean medical doctors for 100 patients, the system showed an approximately 89% agreement rate with the clinical diagnoses. The system holds potential for aiding Korean medical doctors in pattern differentiation diagnosis in clinical practice.

  • PDF

The Study on the Clinical Application of the Methods of Sasang Constitution Diagnosis (사상체질(四象體質) 진단법(診斷法)(용모(容貌), 체형(體形), 심성(心性))의 임상적(臨床的) 적용(適用)에 관한 연구(硏究))

  • Kim, Jong-Weon;Jung, Won-Gyo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.2
    • /
    • pp.34-42
    • /
    • 2000
  • Background and Purpose ; Sasang Constitutional medicine is dividing individual's constitutions into four categories. Determination of an individual's constitution however, can be different according to what diagnostic standards apply. In this study, We investigated how different the applying results of the three diagnostic standards-the yong-mo(容貌), the body type(體形), and the mind(心性)-are and what the inter-diagnostic standard agreement is. Methods ; 36 patients in cerebral-infarction, admitted into the Dong-Eui Korean hospital from 1. May. 2000 to 12. October. 2000, were diagnosed by three diagnostic standards - the yong-mo(容貌), the body type(體形), and the mind(心性). Each patient was treated by Sasang constitutional medicine. The agreement of the final constitutional diagnosis and the result of each diagnostic standard was analyzed. Results 1. The number of Taeeumin was 13(40.6%), Soyangin was 10(31.3%), Soeumin was 9(28.1%). 2. In terms of analysis on the agreement of the final constitutional diagnosis and the result of each diagnostic standard, the yong-mo(容貌) showed the highest agreement of 93.8%, followed by 68.8% of the mind(心性), and the body type(體形) showed the lowest agreement of 53.1%. 3. The yong-mo(容貌) standard showed high diagnostic rate of the three constitutions(Soyangin, Taeeumin, Soeumin) generally and diagnostic rate of Soeumin was especially high. The body type(體形) standard showed low diagnostic rate of Taeeumin, and high diagnostic rate of Soeumin. The mind(心性) standard showed low diagnostic rate of Soeumin. 4. In terms of analysis on the agreement of inter-diagnostic standard result, the yong-mo(容貌) and the mind(心性) show the highest agreement, the mind(心性) and the body type(體形) showed the lowest agreement. 5. If the results come out that the three diagnostic standards have no concentration on one constitution, it was effective to choose the result of the yong-mo(容貌) standard. If it is the case the result of inter-diagnostic standard agreed more than two, it was better to follow the two agreed result than to follow the result of one specific characteristic standard.

  • PDF

A Proposal for Standardization of Tongue Diagnosis Based on Diagnostic Criteria of Tongue Coating Thickness (설진의 표준화를 위한 제언 : 설태 후박의 진단기준을 중심으로)

  • Son, Ji-Hee;Kim, Jin-Sung;Park, Jae-Woo;Ryu, Bong-Ha
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Background : In oriental medicine, the status of the tongue is an important indicator to diagnose the condition of one's health, such as physiological and the clinicopathological changes of internal organs. A tongue diagnosis is not only convenient but also non-invasive, and therefore widely used in Oriental medicine. However, the tongue diagnosis is greatly affected by examination circumstances, patient's posture, and doctor's diagnosis criteria. Objectives : This study was designed to assure the necessity for standardization of tongue diagnosis based on diagnostic criteria of tongue coating thickness (TCT). Methods : Thirty tongue photographs were acquired and analyzed by digital tongue diagnosis system (DTDS) which measured the percentage of TCT on the tongue surface. Fifteen oriental medical doctors evaluated TCT in 30 photographs. Afterward, the 15 assessors were trained for diagnostic criteria of TCT and evaluated the photographs again. The intraclass correlation coefficient (ICC) was used to obtain the agreement rate among the 15 assessors and the agreement rate between assessors' TCT scores and DTDS values. Results : The agreement rate among the 15 assessors after training was higher than before training. The agreement rate between assessors' TCT scores and DTDS values after training was also higher than before training. Furthermore, the difference of the agreement rate between before and after training was significant (p<0.05). Conclusions : The standardization of diagnostic criteria of TCT increased the agreement rate among the assessors and the agreement rate between assessors' TCT scores and DTDS values. Therefore, the standardization of diagnostic criteria is expected to contribute to the objectification and quantification of the tongue diagnosis system.

Test-Retest Reliability of Brief KS-15 -Korean Sasang Constitutional Diagnostic Questionnaire- (단축형 사상체질 진단 설문지(KS-15)의 검사-재검사 신뢰도 연구)

  • Kim, Yunyoung;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.177-183
    • /
    • 2016
  • The purpose of this study was to evaluate the reliabilities of questions and diagnostic value of the Korean Sasang Constitutional Diagnostic Questionnaire(KS-15). The young adults aged 20's participated in this study. The first survey was conducted in march, 2016, and the second one was conducted two weeks later. Three hundred and three questionnaires and the informed consent were obtained from all participants. The test-retest kappa analysis was used to identify the reliabilities of the questions and diagnostic value, and the significance level was .05. The number of subjects was 303 [87(28.7%)males and 216(71.3%)females]. The Cronbach's α were .630 in 6 characteristic questions. The test-retest reliabilities of questions were ranged from .469 to 734. The agreement rate of KS-15 between the first and second constitutional diagnostic value was 87.13%(Kappa=0.794). The higher Sasang constitutional probability score in first survey resulted in the higher agreement rate between first and second diagnostic value. KS-15 seems to be a reliable implement. Further studies for the reliability of the people of different ages and suitable cut off point in Sasang constitutional probability score are needed for the practical use of KS-15.

Is the diagnosis of calcified laryngeal cartilages on panoramic radiographs possible?

  • Cagirankaya, Leyla Berna;Akkaya, Nursel;Akcicek, Gokcen;Dogru, Hatice Boyacioglu
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.121-125
    • /
    • 2018
  • Purpose: Detecting laryngeal cartilages (triticeous and thyroid cartilages) on panoramic radiographs is important because they may be confused with carotid artery calcifications in the bifurcation region, which are a risk factor for stroke. This study assessed the efficiency of panoramic radiography in the diagnosis of calcified laryngeal cartilages using cone-beam computed tomography (CBCT) as the reference standard. Materials and Methods: A total of 312 regions(142 bilateral, 10 left, 18 right) in 170 patients(140 males, 30 females) were examined. Panoramic radiographs were examined by an oral and maxillofacial radiologist with 11 years of experience. CBCT scans were reviewed by 2 other oral and maxillofacial radiologists. The kappa coefficient(${\kappa}$) was calculated to determine the level of intra-observer agreement and to determine the level of agreement between the 2 methods. Diagnostic indicators(sensitivity, specificity, accuracy, and false positive and false negative rates) were also calculated. P values <.05 were considered to indicate statistical significance. Results: Eighty-two images were re-examined to determine the intra-observer agreement level, and the kappa coefficient was calculated as 0.709 (P<.05). Statistically significant and acceptable agreement was found between the panoramic and CBCT images (${\kappa}=0.684$ and P<.05). The sensitivity, specificity, diagnostic accuracy rate, the false positive rate, and the false negative rate of the panoramic radiographs were 85.4%, 83.5%, 84.6%, 16.5%, and 14.6%, respectively. Conclusion: In most cases, calcified laryngeal cartilages could be diagnosed on panoramic radiographs. However, due to variation in the calcifications, diagnosis may be difficult.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS (구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구)

  • Kim, Jae-Hwan;Kim, Kyung-Wook;Kim, Yong-Kack
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.

The Rate of Diagnostic Agreement and Concordance Ratings on Psychiatric Recommendation in Consulted Delirious Cases (자문의뢰된 섬망환자에 대한 진단 일치율과 정신과 의견의 반영도)

  • Oh, Eung-Seok;Nam, Jung-Hyun;Kim, Seok-Hyeon;Park, Yong-Chon;Kim, Sung-Mok
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.2
    • /
    • pp.174-181
    • /
    • 2001
  • Objectives : The author investigated the rate of diagnostic agreement between consultants and consultees and concordance ratings on the consultees' recommendation to examine the interactive collaborativeness and find the factors that influence the reflectiveness on treatment. Methods : The subjects were 54 patients with delirium selected from 583 cases referred from other departments who were admitted to Hanyang University Kuri Hospital from July 1, 1995 to Dec. 31, 1997. The information on demographic data, diagnostic impression, symptoms, management before consultation, psychiatric recommendation, management after consultation, diagnoses at the referring departments and the psychiatric department on delirium was obtained by medical records and consultation papers retrospectively. The reflectiveness of the psychiatric recommendation was divided into complete concordance, partial concordance, and nonconcordance and among them the complete and partial concordance were considered for concordance. The reflectiveness was compared among all the departments and between medical unit and surgery unit. Results: The rate of diagnostic agreement on the cause of delirium was highest(85.7%) in organic brain syndrome and lowest in general medical condition(0%). There was no statistically significant differences between medical unit and surgery unit. Neither differences were there among all the departments. In comparing symptoms affecting the reflectiveness, it was 73.5% in impulsive and aggressive behavioral changes, whereas 40.0% in behavioral changes. Reflectiveness of psychiatric recommendation showed higher scores in the case of behavioral changes. The cases of sleep problem showed higher scores of reflectiveness. When these two symptoms of behavioral change and sleep problem were compared as one factor, the results suggested that there were significant differences. The cases with both two symptoms showed 80% in reflectiveness, and the cases with only one symptom or no symptoms showed 44.8% in reflectiveness. There were no statistical significances between concordance ratings and symptoms such as disturbance of consciousness, disorientation, and hallucination that cannot be easily evaluated at the referring departments. Conclusions : The rate of diagnostic agreement on the cause of delirium was highest in the case of organic brain syndrome in which lesions can be easily recognized. The factors that influence the reflectiveness of psychiatric recommendation were behavior changes and sleep disorders in the symptoms of evaluated cases.

  • PDF

The Comparative studies on Diagnostic Results of Yangdorack and EAV -on the 18 Cases of stroke patients- (양도락과 EAV 진단결과(診斷結果)에 대(對)한 상호비교(相互比較) 연구(硏究) -중풍(中風) 환자(患者) 18예(例)를 중심(中心)으로-)

  • Park Kyoung-Jin;Cho Myung-Rae;Yun Yeo-Chung
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.199-209
    • /
    • 1998
  • We compared and studied the results on two diagnostic machines called Yangdorack and EAV on 18 recovering paralytic patients. The results were as folIows ; 1. Patients with weak motor ability showed an average of 25% fewer units of Yangdorack and an average of 49% fewer units of EAV. 2. Deficiency/excess diagnostic results on meridian and internal organs showed 58.5% deficiency and 41.5% excess on the Yangdorack ; 67.9% of decline-degenerative activity and 32.1% of stimulus-inflarrunation activity on the EAV. 3. In the attack of meridian and internal organs in view of the five elements(五行), in rate of deficiency, decline and degeneration of the fire meridian(火經) in view of the highest rate accounts showed 19.5% on the Yangdorack and 20.4% on the EAV. 4. In comparing deficiency/excess results on the Yangdorack with results of decline-degenerative value and stimulus-inflammation value on the EAV, they both showes a 39% rate. 5. In comparing clinical syndromes on the Yangdorack and common diseases on the EAV, they showed a 72% agreement.

  • PDF