• Title/Summary/Keyword: Diagnostic Value

Search Result 1,368, Processing Time 0.036 seconds

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones (측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구)

  • 민양기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.4-5
    • /
    • 1977
  • The vibratory energy introduced into the external ear canal is changed by the mechanical factors of eardrum itself, the motility of ossicles, and the air cushion of tympanic cavity and the like. This study was designed to investigate the volume of middle ear cavity and mastoid air cell system as a factor of determining the accoustic impedance of middle ear system. The author studied how the increase in air volume of middle ear cavity effects on the acoustic impedance of middle ear system with dogs' ears and researched the correlation between the degree of pneumatization of temporal bones and the acoustic impedance of middle ear system by comparing the radiological findings of pneumatization (Law's and Towne's projection) with the acoustic impedance measurements with Madsen ZO 70. The result is as follows: 1 The tympanometric findings in control state revealed the curves of type A, and did not change in its configuration by the increase in the air volume of dogs middle ear system. 2. The static compliance of middle ear revealed a distinct and linear increase in proportion to the increase in air volume of middle ear system; the rate of increase was $0.05{\pm}0.02$ cc of static compliance per cc of air volume. 3. Authenticated in the above result and the tendency to increase in static compliance in proportion to the increase in the degree of pneumatization of temporal bones, there was significant regression equation between the degree of pneumatization of temporal bones (x variable) and the static compliance of middle ear system; $y=0.19x{\pm}0.16{\pm}0.05$ It is suggested that the difference in volume of middle ear system plays an important role in the change of the static compliance of middle ear, and the author concludes that the measurement of static compliance of middle ear has clinical value as diagnostic means of evaluating the degree of pneumatization of temporal bones along with some radiological examination.

  • PDF

Experimental Studies on Lead Toxicity in Domestic Cats 1. Symptomatology and Diagnostic Laboratory Parameters (고양이의 납중독에 관한 실험적 연구 1. 임상증상 및 실험실적 평가)

  • Hong Soon-Ho;Han Hong-Ryul
    • Journal of Veterinary Clinics
    • /
    • v.10 no.1
    • /
    • pp.111-130
    • /
    • 1993
  • Lead toxicity was evaluated in forty-five cats on a balanced diet, Treated with 0(control), 10, 100(low), 1, 000, 2, 000, and 4, 000(high) ppm of lead acetate orally on a body weight basis. The objectives were to establish toxic dosage level of leaf in cats, to characterize changes in behavior and clinical pathology, and to demonstrate what blood lead concentrations correlate with the known dosages of lead. Some high dose cats showed projectile vomiting, hyperactivity, and seizures. The growth rates did not appear to be altered in any of the dosed groups. Normal blood lead concentration in cats were lower than that of humans, dogs, and cattle. Blood lead concentrations of 3 to 20$\mu\textrm{g}$/100$m\ell$ could be termed a 'subclinical' range in the cat. Clinical lead toxicity in cats may have blood lead concentrations ranging 20 to 120$\mu\textrm{g}$/100$m\ell$. Zinc protoporphyrin concentrations were proportional to lead dosages and a significant ZPP elevation, greater than 50$\mu\textrm{g}$/100$m\ell$, may be indicative of clinical lead toxicity. The enzyme aminolevulinic acid dehydratase showed an inverss dose response relationship for all lead dosages and a significant ZPP elevation, greater than 50$\mu\textrm{g}$/100$m\ell$, may be indicative of clinical lead toxicity. The enzyme aminolevulinic acid dehydratase showed an inverse dose response relationship for all lead dosages and appears to be a good indicator of lead exposure in cats. Urinary aminolevuliruc acid concentrations generally increased with lead dosage, but individual values varied. Hair lead concentrations rose proportionately to lead dosages. Lead at least in high doses appears to inhibit chemotactic activity of polymorphonuclear cells and monocytes. No consistent dose response relationships were observed in hemoglobin, RBC, WBC, neutrophil, lymphocyte, monocyte, and eosinophil counts. There were no consistent dose related changes in total protein, plasma protein, BUN, and ALT values. Reticulocyte counts did not increase significantly in most lead dosage levels, and are probably of little value in diagnosing lead toxicity in cats. The fact that no significant changes were found in nerve conduction velocities may support that there was no segmental demyelination resulting from lead ingestion. The lethal dose in cats appear to range from 60 to 150mg/kg body weight. A reliable diagnosis of lead poisoning can be made utilizing blood lead, ZPP, and ALAD, and hair lead.

  • PDF

Usability of Urinary Reagent Strips in Diagnosis of Meningitis (뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성)

  • Jeong, Jin Yeong;Park, Sang Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.265-270
    • /
    • 1997
  • Purpose: Rapid diagnosis and prompt treatment remain the cornerstone of management of patients with meningitis. Examination of cerebrospinal fluid(CSF) for glucose, protein, cells, and organisms is necessary for accurate diagnosis, but in many parts of the world facilities do not exist to do so. We tested CSF samples from 69 children with suspected meningitis with urinary reagent strips and analyzed the results to know the usability of urinary reagent strips in diagnosis of meningitis. Methods: 69 CSF samples obtained from children with suspected meningitis were analysed. Each sample was divided into two; one was sent to the laboratory for routine diagnostic evaluation, and the other was tested with the reagent strip(Combur10 Test M). Laboratory values of CSF glucose, protein, and leucocytes for each CSF sample were plotted against the corresponding reagent-strip category. Results: There was good agreement between the dipstick and laboratory values for CSF protein and cell count but not for glucose. Conclusion: Rapid diagnosis of meningitis could be made with three component of the Combur10 test strip. It is easy to do and would be of particular value to those working in parts of the world where no laboratory facilities exist.

  • PDF

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

Study on Volume Measurement of Cerebral Infarct using SVD and the Bayesian Algorithm (SVD와 Bayesian 알고리즘을 이용한 뇌경색 부피 측정에 관한 연구)

  • Kim, Do-Hun;Lee, Hyo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.591-602
    • /
    • 2021
  • Acute ischemic stroke(AIS) should be diagnosed within a few hours of onset of cerebral infarction symptoms using diagnostic radiology. In this study, we evaluated the clinical usefulness of SVD and the Bayesian algorithm to measure the volume of cerebral infarction using computed tomography perfusion(CTP) imaging and magnetic resonance diffusion-weighted imaging(MR DWI). We retrospectively included 50 patients (male : female = 33 : 17) who visited the emergency department with symptoms of AIS from September 2017 to September 2020. The cerebral infarct volume measured by SVD and the Bayesian algorithm was analyzed using the Wilcoxon signed rank test and expressed as a median value and an interquartile range of 25 - 75 %. The core volume measured by SVD and the Bayesian algorithm using was CTP imaging was 18.07 (7.76 - 33.98) cc and 47.3 (23.76 - 79.11) cc, respectively, while the penumbra volume was 140.24 (117.8 - 176.89) cc and 105.05 (72.52 - 141.98) cc, respectively. The mismatch ratio was 7.56 % (4.36 - 15.26 %) and 2.08 % (1.68 - 2.77 %) for SVD and the Bayesian algorithm, respectively, and all the measured values had statistically significant differences (p < 0.05). Spearman's correlation analysis showed that the correlation coefficient of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was higher than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (r = 0.915 vs. r = 0.763 ; p < 0.01). Furthermore, the results of the Bland Altman plot analysis demonstrated that the slope of the scatter plot of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was more steady than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (y = -0.065 vs. y = -0.749), indicating that the Bayesian algorithm was more reliable than SVD. In conclusion, the Bayesian algorithm is more accurate than SVD in measuring cerebral infarct volume. Therefore, it can be useful in clinical utility.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Digital Breast Tomosynthesis as a Breast Cancer Screening Tool for Women with Gynecologic Cancer (부인암을 가진 여성에서 유방암의 선별검사로서의 디지털 유방단층 촬영술)

  • Da-hoon Kim;Jin Chung;Eun-Suk Cha;Jee Eun Lee;Jeoung Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.886-898
    • /
    • 2020
  • Purpose The purpose of our study was to evaluate digital breast tomosynthesis as a breast cancer screening modality for women with gynecologic cancer. Materials and Methods This retrospective study included patients with underlying gynecologic malignancies who underwent screening digital breast tomosynthesis for breast cancer. The cancer detection rate, recall rate, sensitivity, specificity, and positive predictive value (PPV) were calculated. PPV1 was defined as the percentage of all positive screening exams that have a tissue diagnosis of cancer within a year. PPV2 was defined as the percentage of all diagnostic exams (and Breast Imaging Reporting and Data System category 4, 5 from screening setting) with a recommendation for tissue diagnosis that have cancer within a year. PPV3 was defined as the percentage of all known biopsies actually performed that resulted in a tissue diagnosis of cancer within the year. For each case of screen-detected cancer, we analyzed the age, type of underlying gynecologic malignancy, breast density, imaging features, final Breast Imaging Reporting and Data System assessment, histologic type, T and N stages, molecular subtype, and Ki-67 index. Results Among 508 patients, 7 with breast cancer were identified after a positive result. The cancer detection rate was 13.8 per 1000 screening exams, and the recall rate was 17.9%. The sensitivity was 100%, and the specificity was 83.2%. The false negative rate was 0 per 1000 exams. The PPV1, PPV2, and PPV3 were 7.7, 31.8, and 31.8, respectively. Conclusion Digital breast tomosynthesis may be a promising breast cancer screening modality for women with gynecologic cancer, based on the high cancer detection rate, high sensitivity, high PPV, and high detection rate of early-stage cancer observed in our study.

A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.