• Title/Summary/Keyword: Diagnostic Value

Search Result 1,368, Processing Time 0.03 seconds

Fibulin-3 as a Diagnostic Biomarker in Patients with Malignant Mesothelioma

  • Kaya, Halide;Demir, Melike;Taylan, Mahsuk;Sezgi, Cengizhan;Tanrikulu, Abdullah Cetin;Yilmaz, Sureyya;Bayram, Mehmet;Kaplan, Ibrahim;Senyigit, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1403-1407
    • /
    • 2015
  • Background: New tumour biomarkers are being intensely investigated for malignant mesothelioma (MM). Fibulin-3 is produced in MM but its role remains uncertain. The aim of this study was to evaluate the validity of measuring serum fibulin-3 in the diagnosis and prognosis of MM. Materials and Methods: This prospective study was performed on 43 patients and 40 healthy controls who were admitted to our hospital between January 2012 and January 2014. Data from MM patients, including demographic and clinical features, routine laboratory data, levels of serum fibulin-3, and treatment outcomes were defined as potential prognostic factors. The receiver operating characteristic (ROC) curve for fibulin-3 was used to detect the cut-off value with highest sensitivity and specificity. Univariate survival analysis was performed using the Kaplan-Meier method in patients with MM. Afterwards, the possible factors identified with univariate analyses were entered into the cox regression analysis. Results: Our results revealed that patients with MM had significantly higher serum levels of fibulin-3 than controls. The results showed that the best cut-off point was 36.6 ng/ml with an AUC (area under the curve)=0.976, sensitivity=93.0% and specificity=90.0. In our study, the initial significant poor prognostic factors were advanced stage, high white blood cell count, high platelet count, high C-reactive protein (p<0.05 for each variable). Later, according to multivariate analysis the results showed only advanced stage as significant parameter (p=0.040). Conclusions: We determined that real use for serum fibulin-3 was not for prognosis but for diagnosis in MM. Also advanced stage was associated with poor MM prognosis.

Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm (패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석)

  • Jung, Min Gi;Kim, Soung Min;Kim, Myung Joo;Lee, Jong Ho;Myoung, Hoon;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

Effects of Escherichia coli Contamination on Extended Porcine Semen Parameters

  • So, Kyoung-Min;Sa, Soo-Jin;Kim, Hyo-Jin;Chung, Ki-Hwa;Jung, Byeong-Yeal;Son, Jung-Ho;Kim, In-Cheul
    • Reproductive and Developmental Biology
    • /
    • v.35 no.4
    • /
    • pp.479-483
    • /
    • 2011
  • The objective of this study was to determine the effects of E. coli isolated from porcine semen on sperm viability, motility, and semen pH. Semen samples were prepared using commercial extender, $Seminark^{Pro}$ (Noahbio Tech, Korea) that did not contain antibiotics. And 4 different levels of E. coli were artificially innoculated to semen with following concentrations; 4,000 of sperms with 1 of E. coli (T1), 400 with 1 (T2), 40 with 1 (T3), and 4 with 1 (T4). Semen samples were preserved at $17^{\circ}C$ for 5 days in semen storage box until analyzed by flowcytometer. Aliquots were subjected to measure the sperm viability (Live/$Dead^{(R)}$ stain), motility (mitochondrial function), and semen acidity (pH) from day 0 (day of semen collection) to day 5. Sperm motility and viability were significantly decreased (p<0.05) on day 0 (4 hrs after preservation at $17^{\circ}C$) in T3 and T4 compared to control groups and were significantly decreased (p<0.05) in all groups from day 3. Sample pH was acidic in T3 (6.90~6.86) and T4 (6.86~6.65) from day 3 to day 5 (p<0.05). On the other hand, sample pH was maintained 7.0~7.1 in control, T1, and T2 during the experimental period. Sperm motility and viability were significantly decreased from day 0 to day 5 compared to control in samples contaminated with E. coli above a value of 40:1 ($20{\times}10^6$ sperm cells/ml : $5{\times}10^5$ cfu/ml). Even on day 1 in T4 and on day 3 in T3, semen pH was acidic probably due to the acidification of dead spermatozoa. These results suggest that E. coli contamination has a concentration-dependent detrimental effect on extended porcine semen quality.

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

The Value of Tc-99m DTPA Diuretic Renography for Assessment of Dilated Upper Urinary Tract in Children (소아의 상부 요관확장증에서 폐쇄 유무 감별에 있어 Tc-99m DTPA 이뇨 신장 신티그램의 유용성)

  • Yang, Ki-Ra;Lim, Gye-Yeon;Sohn, Hyung-Sun;Hahn, Seong-Tae;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. Materials and Methods: We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Results: Six patients required Pyeloplasty and eight were managed conservatively. All 6 patients requiring Pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans at 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Conclusion: Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern.

  • PDF

Role of PET in Evaluating Indeterminate Solitary Pulmonary Nodule with CT (CT상 악성여부가 불명확한 단일 폐결절에서의 양전자방출단층촬영술의 유용성)

  • Yoon, Seok-Boo;Choi, Joon-Young;Kim, Sun-Jung;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Sang-Eun;Kwon, O-Jung;Lee, Kyung-Soo;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.83-89
    • /
    • 1997
  • About one-third of radiologically indeterminate solitary pulmonary nodules (SPN) are eventually turned out to be malignant. It is very important to noninvasively determine whether the SPN is malignant or not for the decision of its way of management. PET imaging is highlighted by its unique ability of imaging the function and metabolism of cells. Glucose metabolism is increased in malignant transformed cells. We peformed FDG-PET studies in patients who had radiologically indeterminate SPN and compared the findings with histologic diagnoses to assess the diagnostic accuracy in the detection of malignancy and to decide which parameter is the most suitable for clinical practice among peak SUV (pSUV), average SUV (aSUV), 50/10 ratio, and time-activity curve (TAC), Thirty patients were included in this study and the most useful parameter was pSUV. The sensitivity and specificity in the detection of malignant SPN using 3.5 as a cut off pSUV were both 87%. Interestingly, all 2 false-negative cases were bronch-ioloalveolar carcinoma on histologic examination. If these cases, which could be strongly suspected by CT findings, were excluded, the sensitivity of pSUV was 100%. In conclusion, PET imaging is very helpful for determining malignancy in indeterminate SPN and pSUV is a conveniently measurable parameter which is valuable for interpretation.

  • PDF

Differentiation of Vocal Cyst and Polyp by High-Piched Phonation Characteristics (성대낭종과 성대폴립 간의 고음발성 양상의 차이)

  • Lee, Jong-Ik;Jeong, Go-Eun;Kim, Seong-Tae;Kim, Sang-Yeon;Nam, Soon-Yuhl;Kim, Sang-Yoon;Roh, Jong-Lyel;Choi, Seung-Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.23 no.1
    • /
    • pp.48-51
    • /
    • 2012
  • Background and Objectives : Vocal fold cyst is generally treated by surgical resection, it has a difference with vocal fold polyp, treated by conservative management first. Decrease in mucosal waves is known as main diagnostic criteria of vocal fold cyst. Sometimes there is a difficulty for diffrential diagnosis between cyst and polyp only by endoscopic examination. The purpose of the study is to identify the objective features of vocal cyst and polyp on the basis of voice analysis for the proper differential diagnosis, especially at high pitched phonation. Materials and Method : The voice analysis was done in 15 focal fold cyst patients and 42 vocal fold polyp. Parameters of perceptual assessment, acoustic and aerodynamic measure, and voice range profile were compared between two groups. Results : Vocal fold cyst patients showed significantly reduced MPT by acoustic and aerodynamic analysis, narrowed frequency-range and low maximun frequency by voice range profile analysis compared with vocal fold polyp patient. Maximun frequency 381 Hz is established for cut off value, differential diagnosis between cyst and polyp (ROC analysis, sensitivity 60%, specificity 68%). Conclusion : Voice analysis is helpful for differential diagnosis between vocal fold cyst and polyp, especially there is a difficulty for distinguish cyst from polyp at clinical situation by endoscopic examination. The result of decreased maximum frequncy at vocal fold cyst supports incomplete high-pitched phonation and falsetto regester at vocal fold cyst patients due to decreased mucosal wave, compared with vocal fold polyp patients.

  • PDF

Effects of TLR4 Variants on Fasting Glucose Levels in a Korean Population (한국인에서 TLR4 변이가 공복 시 혈당에 미치는 효과)

  • Kim, Gi Tae;Sull, Jae Woong;Jee, Sun Ha
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.345-349
    • /
    • 2017
  • Diabetes mellitus is associated with a variety of adverse health outcomes, including metabolic syndrome and cardiovascular diseases. Recently, diabetes has been receiving increased scientific attention because of the rapid increase in the diabetic population. One of the features of type-2 diabetes mellitus is an elevated glucose level in blood. Fasting glucose level, which is the most basic test, is widely used as a diagnostic indicator of diabetes. Several previous studies reported that TLR4 expression is relatively high in the heart. However, few studies have investigated the association between TLR4 variants and fasting blood glucose to date. Thus, this study tested the association between single nucleotide polymorphisms (SNPs) in the TLR4 gene and fasting glucose in the Korean population. A total of 994 subjects recruited from Seoul were used for the present study. When compared to fasting blood glucose, the TLR4 gene region was shown as a linkage disequilibrium owing to the relatively large gene range. This region also presented as several LD blocks. We found that specific SNPs in the TLR4 gene were associated with the mean fasting glucose (p<0.01). The minor allele frequency of rs1329067 was 16.4%, and individuals with the AA genotype had a higher fasting blood glucose level than those with the GG genotype, suggesting that genetic variants in TLR4 influence glucose levels in Korean adults.

Carpal Tunnel Syndrome among Packing Workers in A Rayon Manufacturing Factory (모 사업장 포장부서 근로자들에서 발생한 수근터널증후군에 대한 조사연구)

  • Lee, Won-Jin;Lee, Eun-Il;Cha, Chul-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.1 s.37
    • /
    • pp.26-33
    • /
    • 1992
  • The carpal tunnel syndrome is one of the most common peripheral nerve entrapment syndromes. The typical symptoms are pain, numbness and paresthesia in the median nerve territory of the hand. Recently, it is widely recognized that occupational factor is regarded as the important cause of the carpal tunnel syndrome. Clinical study is performed in the 42 female workers who is repetitively working at packing department in a rayon manufacturing factory from November 1991 till March 1992. The study included a questionnaire, physical examinations, and the neurophysiological test. The summary of the results obtained was as follows : 1. Among 42 packing workers, 9 workers(21.4%) were diagnosed as carpal tunnel syndrome by electromyography. The affected side was bilateral in 4 workers(9.5%), right in 4 workers(9.5%), and left in one worker(2.4%). 2. Among 42 subjects, 28 workers(66.7%) complained the clinical symptoms related to carpal tunnel syndrome, 11 workers(26.2%) showed positive Phalen sign, and 7 workers(16.7%) showed positive Tinel sign. 3. Researchers regard electromyographic finding as the gold standard for diagnosis of carpal tunnel syndrome. The sensitivity and specificity of the clinical symptoms to diagnose the carpal tunnel syndrome were 0.89, 0.39 respectively. If the carpal tunnel syndrome is diagnosed by the combination of the positive findings of the symptoms and the physical examinations, either Tinel or Phalen sign, the sensitivity and specificity were 0.67 and 0.76 respectively. Considering above results, though this small number of workers is not adequate for epidemiologic conclusions, carpal tunnel syndrome seems to be an important occupational disorder among packing workers in a rayon manufacturing factory.

  • PDF