• 제목/요약/키워드: Diagnostic Technique of Structure

검색결과 47건 처리시간 0.022초

Three-dimensional analysis of dermal backflow in cancer-related lymphedema using photoacoustic lymphangiography

  • Oh, Anna;Kajita, Hiroki;Imanishi, Nobuaki;Sakuma, Hisashi;Takatsume, Yoshifumi;Okabe, Keisuke;Aiso, Sadakazu;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.99-107
    • /
    • 2022
  • Background Dermal backflow (DBF), which refers to lymphatic reflux due to lymphatic valve insufficiency, is a diagnostic finding in lymphedema. However, the three-dimensional structure of DBF remains unknown. Photoacoustic lymphangiography (PAL) is a new technique that enables the visualization of the distribution of light-absorbing molecules, such as hemoglobin or indocyanine green (ICG), and can provide three-dimensional images of superficial lymphatic vessels and the venous system. This study reports the use of PAL to visualize DBF structures in the extremities of patients with lymphedema after cancer surgery. Methods Patients with a clinical or lymphographic diagnosis of lymphedema who previously underwent surgery for cancer at one of two participating hospitals were included in this study. PAL was performed using the PAI-05 system. ICG was administered subcutaneously in the affected hand or foot, and ICG fluorescence lymphography was performed using a near-infrared camera system prior to PAL. Results Between April 2018 and January 2019, 21 patients were enrolled and examined using PAL. The DBF was composed of dense, interconnecting, three-dimensional lymphatic vessels. It was classified into three patterns according to the composition of the lymphatic vessels: a linear structure of lymphatic collectors (pattern 1), a network of lymphatic capillaries and lymphatic collectors in an underlying layer (pattern 2), and lymphatic capillaries and precollectors with no lymphatic collectors (pattern 3). Conclusions PAL showed the structure of DBF more precisely than ICG fluorescence lymphography. The use of PAL to visualize DBF assists in understanding the pathophysiology and assessing the severity of cancer-related lymphedema.

Production of a Recombinant Anti-Human CD4 Single-Chain Variable-Fragment Antibody Using Phage Display Technology and Its Expression in Escherichia coli

  • Babaei, Arash;Zarkesh-Esfahani, Sayyed Hamid;Gharagozloo, Marjan
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권5호
    • /
    • pp.529-535
    • /
    • 2011
  • Single-chain variable fragment (scFv) is a fusion protein of the variable regions of the heavy (VH) and light (VL) chains of immunoglobulin, connected with a short linker peptide of 10 to about 20 amino acids. In this study, the scFv of a monoclonal antibody against the third domain of human CD4 was cloned from OKT4 hybridoma cells using the phage display technique and produced in E. coli. The expression, production, and purification of anti-CD4 scFv were tested using SDS-PAGE and Western blot, and the specificity of anti-CD4 scFv was examined using ELISA. A 31 kDa recombinant anti-CD4 scFv was expressed and produced in bacteria, which was confirmed by SDS-PAGE and Western blot assays. Sequence analysis proved the ScFv structure of the construct. It was able to bind to CD4 in quality ELISA assay. The canonical structure of anti-CD4 scFv antibody was obtained using the SWISS_MODEL bioinformatics tool for comparing with the scFv general structure. To the best of our knowledge, this is the first report for generating scFv against human CD4 antigen. Engineered anti-CD4 scFv could be used in immunological studies, including fluorochrome conjugation, bispecific antibody production, bifunctional protein synthesis, and other genetic engineering manipulations. Since the binding site of our product is domain 3 (D3) of the CD4 molecule and different from the CD4 immunological main domain, including D1 and D2, further studies are needed to evaluate the anti-CD4 scFv potential for diagnostic and therapeutic applications.

Estimation of Thickness of Concrete Structures using the Impact Echo Method and Ultrasonic Pulse Velocity Method

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Lee, Changsik
    • Architectural research
    • /
    • 제18권4호
    • /
    • pp.179-184
    • /
    • 2016
  • The structure must be periodically checked and measures must be taken to prevent deterioration in building construction. From this point of view, a nondestructive test is essential to estimate whether the construction of buildings is proper, and whether the dimension of depositing concrete is consistent and without damage. This study estimated the thickness of the concrete component of construction framework using the ultrasonic velocity method and the impact echo method, in order to investigate reliability of the estimation of the thickness of normal strength concrete and high strength concrete, leading to the following conclusions. In the estimation of the thickness of the concrete structures, specimens of normal strength of 24MPa and specimens of high strength of 40MPa demonstrated an average error rate of 5.1% and 2.2%, respectively. The impact-echo method, one of the non-destructive tests, is verified as an efficient diagnostic technique. With this information, we will determine specific standards for the maintenance of structures, and the re-creation of lost building blueprints.

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

Application on the New Technology of Construction Structures Disaster Protection Management based on Spatial Information

  • Yeon, Sangho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.136-145
    • /
    • 2018
  • The disaster monitoring technique by combination of the measurement method and the fine precision of the sensor collecting the satellite-based information that can determine the displacement space is available in a variety of diagnostic information and the GIS/GNSS by first sensor it is being requested from them. Be large and that the facility is operated nationally distributed torsional displacement of the terrain and facilities caused by such natural disasters progress of various environmental factors and the surroundings. To diagnose this spatial information, which contains the various sensors and instruments tracks the precise fine displacement of the main construction structures and the first reference in the Geospatial or more three-dimensional detailed available map and location information using the installed or the like bridges and tunnels produced to a USN/IoT change at any time, by combining the various positioning analysis of mm-class for the facility main area observed is required to constantly in the real time information of the USN/IoT environment sensor, and to utilize this as a precise fine positioning information by UAV/Drone to the precise fine displacement of the semi-permanent infrastructures. It managed to be efficient management by use of new technologies, analyzing the results presented to a method capable of real-time monitoring for a large structure or facility to construction disaster prevention.

Advanced performance evaluation system for existing concrete bridges

  • Miyamoto, Ayaho;Emoto, Hisao;Asano, Hiroyoshi
    • Computers and Concrete
    • /
    • 제14권6호
    • /
    • pp.727-743
    • /
    • 2014
  • The management of existing concrete bridges has become a major social concern in many developed countries due to the large number of bridges exhibiting signs of significant deterioration. This problem has increased the demand for effective maintenance and renewal planning. In order to implement an appropriate management procedure for a structure, a wide array of corrective strategies must be evaluated with respect to not only the condition state of each defect but also safety, economy and sustainability. This paper describes a new performance evaluation system for existing concrete bridges. The system evaluates performance based on load carrying capability and durability from the results of a visual inspection and specification data, and describes the necessity of maintenance. It categorizes all girders and slabs as either unsafe, severe deterioration, moderate deterioration, mild deterioration, or safe. The technique employs an expert system with an appropriate knowledge base in the evaluation. A characteristic feature of the system is the use of neural networks to evaluate the performance and facilitate refinement of the knowledge base. The neural network proposed in the present study has the capability to prevent an inference process and knowledge base from becoming a black box. It is very important that the system is capable of detailing how the performance is calculated since the road network represents a huge investment. The effectiveness of the neural network and machine learning method is verified by comparing diagnostic results by bridge experts.

증강현실 기반의 최소침습수술용 인터페이스의 개발 (Development of Immersive Augmented Reality interface for Minimally Invasive Surgery)

  • 문진기;박신석;김유진;김진욱
    • 로봇학회논문지
    • /
    • 제3권1호
    • /
    • pp.58-67
    • /
    • 2008
  • This study developed a novel augmented reality interface for minimally invasive surgery. The augmented reality technique can alleviate the sensory feedback problem inherent to laparoscopic surgery. An augmented reality system merges real laparoscope image and reconstructed 3D patient model based on diagnostic medical image such as CT, MRI data. By using reconstructed 3D patient model, AR interface could express structure of patient body that is invisible outside visual field of laparoscope. Therefore, an augmented reality system improved sight information of limited laparoscope. In our augmented reality system, the laparoscopic view is located at the center of a wide-angle concave screen and reconstructed 3D patient model is displayed outside the laparoscope. By using a joystick, the laparoscopic view and the reconstructed 3D patient model view are changed concurrently. With our augmented reality system, the surgeon can see the peritoneal cavity from a wide angle of view, without having to move the laparoscope. Since the concave screen serves immersive environments, the surgeon can feel as if she is in the patient body. For these reasons, a surgeon can recognize easily depth information about inner parts of patient and position information of surgical instruments without laparoscope motion. It is possible for surgeon to manipulate surgical instruments more exact and fast. Therefore immersive augmented reality interface for minimally invasive surgery will reduce bodily, environmental load of a surgeon and increase efficiency of MIS.

  • PDF

A comparative study of 3D printing and sol-gel polymer production techniques: A case study on usage of ABS polymer for radiation shielding

  • Hasan Ogul;Batuhan Gultekin;Fatih Bulut;Hakan Us
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.1943-1949
    • /
    • 2024
  • This study focuses on the comparative analysis of ABS polymer samples produced using two distinct manufacturing techniques: 3D printing and the sol-gel methods. In the first approach, ABS polymer was augmented with rare earth oxides, Er2O3 and Gd2O3, in nano powder form and fabricated into test specimens using 3D printing technology. In the second approach, identical samples were prepared via the sol-gel technique involving mold-based fabrication. Elemental content analysis revealed no significant differences between the samples produced by the two methods. The study proceeds to evaluate the gamma-ray shielding, neutron shielding, temperature resistance, and SEM/EDS pictures of ABS samples generated through both techniques. 3D printing method exhibited more favorable results in terms of structure morphology and thermal stability while there is no significant difference for radiation shielding. The results provide insights into the performance and suitability of each production method for radiation shielding applications. This research not only contributes to enhancing radiation shielding technology but also informs the selection of the most appropriate fabrication method for specific applications in nuclear technologies and diagnostic energy range in medical purposes.

안면부 연조직 진단에서 외래기반 초음파의 사용 : 증례 보고(3례) 및 문헌 고찰 (Use of office-based ultrasonography for soft tissue lesions : A report of 3 cases with literature review)

  • 김재영;김민규;이성화;김형준;남웅
    • 대한치과의사협회지
    • /
    • 제53권2호
    • /
    • pp.143-152
    • /
    • 2015
  • Ultrasonography is relatively inexpensive, non-invasive imaging tool and provides real-time imaging. In addition, the images can be obtained repeatedly. But it is not widely used by dentists because it is hard to interpret and technique sensitive. Above all, ultrasonography cannot be used for hard tissue diagnosis. However, ultrasonography can be applied for diagnosis of infection, soft tissue tumor and inflammatory muscle diseases which are commonly found in dental outpatients. Generally, it shows well-defined border, hypoechoic and homogenous structure in case of benign tumor. Malignant tumor appears relatively irregular margin and heterogenous structure. Cyst represents relatively echo-free features compared with benign tumor. Although the general characteristics of abscess are similar with benign tumor, we can observe an increased vascularity and different clinical features. The purpose of this report is to present 3 cases of US images using office-based ultrasonography with their features and discuss the role of office-based ultrasound in dentistry for diagnosis of soft tissue lesions with literature review.

측두하악관절 주변인대 질환의 초음파영상 (Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints)

  • 홍수민;임영관;김병국
    • Journal of Oral Medicine and Pain
    • /
    • 제33권4호
    • /
    • pp.387-394
    • /
    • 2008
  • 목적 : 측두하악장애 환자에서 고가의 자기공명영상 진단을 대신하여 상대적으로 경제적인 진단방법으로 고해상도 초음파 영상을 도입하는데 있어서 그 정확성과 유용성을 확인하고자 하였다. 방법 : 측두하악장애의 임상적 증상 중 과두걸림, crepitation과 함께 통증을 호소하는 20명의 환자를 대상으로 하였다. 고해상도 초음파 촬영을 시행하였고, 고해상도를 가진 초음파촬영시의 결과를 비교하기 위하여, 통상적인 방사선 사진인 측두하악관절의 횡두개 촬영을 Accurad X-200으로, 그리고 Dental CT를 촬영하였으며, 이를 임상소견과 더불어 비교항목으로 선택하였다. 고해상도 초음파의 진단학적 가지 평가를 위하여 통계학적으로 감수성, 특이성, 양성예상치, 음성예상치 및 정확도를 계산하였다. 결과 : 고해상도의 초음파 영상은 골관절염성 변화를 진단하는데 67.5%의 정확도를 보였으며, 관절원판의 위치변화를 진단하는데 92.5%를 보였으나, 관절 주변조직인 관절낭, 관절원판 후조직 그리고 주변 인대의 이상을 측정하는데 있어서 정확도가 55%를 나타내었다. 결론 : 향후 초음파 영상을 얻기 위한 적절한 기기의 발전과 고주파수의 transducer 등이 개발되고 시술자의 훈련과 경험이 쌓이게 되면 매우 우수한 그리고 비침습적이고 접근이 용이하며 경제적인 진단학적인 검사방법으로서 일반적인 도입이 가능할 것으로 사료된다.