• 제목/요약/키워드: Diagnostic Radiation Generator

검색결과 35건 처리시간 0.021초

방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단 (Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers)

  • 김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석 (Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea)

  • 강경묵;서태영;김용상;윤선종
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2020
  • 다양한 종류의 방사선 발생장치가 동물병원에서 사용되면서 방사선 관계종사자들의 안전이 중요해지고 있으나 방사선 발생장치 및 방사선 관계종사자들에 대한 안전관리 정보가 없는 실정이다. 이에 본 연구에서는 방사선 검사기관 및 측정기관, 시·군·구에서 조사되어진 방사선 발생장치 및 관계종사자, 피폭선량 등을 조사, 분석하였다. 최근 6년간 동물병원에서의 방사선 발생장치와 관계종사자 수는 각각 2,138대에서 2,972대, 2,644명에서 5,733명으로 증가하였다. 2019년 방사선 발생장치의 수는 일반 X-ray, CT, C-arm, 이동형 X-ray, 치과용 X-ray는 각각 2,204대, 58대, 67대, 770대, 14대인 것으로 조사되었다. 2019년 방사선 관계종사자 수는 수의사 4,236명, 수의간호사 1,080명, 업무보조원 404명, 기타 13명인 것으로 조사되었다. 2018년 방사선 관계종사자 연간평균피폭선량은 표층선량 0.21mSv, 심부선량 0.18mSv인 것으로 나타났다. 본 연구는 동물병원에서 사용하고 있는 방사선 발생장치 및 방사선 관계종사자의 안전관리에 대한 기초 자료가 될 것으로 기대한다.

일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가 (Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield)

  • 김승욱;안병주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.895-908
    • /
    • 2018
  • 의료방사선의 관리에서 가장 중요한 사항은 진료의 적정성을 확보하면서 방사선위해를 최소화하는 것이다. 국제원자력기구는 진단방사선 분야의 선량 감소 방법에 대한 지침서를 만들어 환자피폭선량을 측정하여 각 국가에 사용하도록 권고하고 있다. 또한 국내에서도 우리나라의 실정에 맞게 각 촬영마다 환자 피폭 선량값을 연구하여 진단참고준위를 제시하였다.환자가 질병 때문에 방사선 진료를 받는 것은 방사선 때문에 일어날 수 있는 위해보다 그것으로 얻어지는 이익이 크기 때문이다. 병실 이동검사와 같이 자신의 질병과 무관하게 방사선에 노출되는 환자 및 보호자들의 피폭을 줄이기 위해서는 환자, 방사선사, 의사 및 의료기관의 노력이 가장 중요하다.이에 본 연구에서는 개선방안의 일환으로 MG로 병실의 이동 검사에 대한 문제점을 제시하고 이 문제점을 근거로 하여 산란선으로 예상되는 공간선량률을 분석하였다. MG에 자체 개발한 방어벽을 설치하여 방어벽 설치 전후의 공간선량률을 측정하여 그 감소율을 분석하였다. 최종적으로 이 자료들을 종합하여 MG에 방어벽을 부착하여 방사선사의 병실이동에 대한 부담감의 최소화, 병실 이동검사로 인한 방사선사, 환자 및 보호자를 방사선 노출로부터 보호하고, 검사로 인한 주위 환자 및 보호자의 불편을 최소화하는데 의의가 있다. 이와 같은 개선안에 대해 보다 효율적인 시행을 위하여 MG에 대한 새로운 법 제도가 마련되면, 향후 예상되는 비용, 인력, 고객만족도 및 더욱 더 안정적인 피폭감소방안이 정착될 것이라 사료된다.

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

정류방식에 따른 진단용 X-선 장치의 출력비교 (A Comparative Study on Output of Four Type Diagnostic X-ray Equipments)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

형광유리선량계의 계측 직선성 연구 (A Study on the Measurement Linearity of Photoluminescent Dosimeter)

  • 정경환;정동경;서정민
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.841-847
    • /
    • 2021
  • 방사선을 이용하는 관련 기관은 국내에 연구, 의료, 교육 등 다양하다. 최근에는 검진 및 의료기관의 방문 횟수가 증가하고 있다. 이로 인해 의료기관에서 방사선학적 검사 횟수가 증가하고 있다. 방사선작업종사자의 피폭뿐만 아니라 방사선 안전관리가 필요하다. 안전관리를 위해서 우선적으로 개인피폭선량계의 올바른 착용 및 착용 후 정확한 측정이 필요하다. 본 연구는 진단용 방사선발생장치의 방사선에 의한 PLD 소자의 계측 직선성을 평가하고 검증하려고 한다. 방사선 분할 조사 시간간격은 10, 30, 60 sec로 10회 조사와 거리에 따라 흡수선량 변화를 측정하기 위해서 조사거리를 30 ~ 100 cm까지 10 cm 간격으로 조사 후 측정하였다. 그 결과 시간 간격에 의한 흡수선량은 차이가 없었다. 이는 고흡수선량 연구에 진단용발생장치를 이용하여 다양한 연구에 도움이 될 것으로 여겨진다.

진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구 (A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment)

  • 허예지;김교태;노시철;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제8권3호
    • /
    • pp.105-110
    • /
    • 2014
  • 국내 진단용 방사선 발생장치는 3년 주기로 시행되는 정기적인 정도관리 검사에 앞서 일별, 주별, 월별, 분기 반기별로 시행하는 수시 정도 관리에 대한 항목 및 규정이 명확하게 지정되어 있지 않다. 미국과 유럽 등의 선진국에서는 정도 관리 항목에 대해 검사를 수행하는 검사자를 구분하여 국가 기관에 보고하도록 되어 있으므로 체계적인 검사 수행과 더불어 검토가 가능하다. 그러므로 의료 장비의 현대화가 이루어지는 시점에서 국외의 주기별 정도관리 시스템을 국내 진단용 방사선 발생 장치에 적합하도록 도입하여 정도관리 항목과 기준의 재정립이 반드시 필요하다. 이에 본 논문에서는 진단용 방사선 발생장치 중 가장 빈번히 사용되고 있는 일반 X선 촬영 장치의 3년 정기점검 사이에 주기적인 수시 정도 관리 검사 항목과 방법 및 기준 수립을 위해 미국, 캐나다 등의 국외 문헌 조사 및 국제 전자 기술 위원회(International Electro-technical Commission, IEC)의 규정 항목과 비교하였다. 이를 바탕으로 국내 수시 정도관리 항목 신설 시 필요한 검사 항목 및 기준 설정을 위한 기초 자료로 제시하고자 하였다.

몬테카를로 전산해석에 의한 X선 실습실의 공간선량분포 평가 (Assessment of Spatial Dose Distribution in the Diagnostic Imaging Laboratory by Monte Carlo Simulation)

  • 조윤형;강보선
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.423-428
    • /
    • 2017
  • 본 연구에서는 몬테카를로 전산해석법으로 K대학교 진료영상 촬영 실습실의 방사선 조사실과 발생장치 제어실 내부 공간 유효선량률 분포 계산을 수행하였다. 방사선 발생장치는 최대 관전압 150 kVp에 최대 관 전류 700 mA이다. 전산해석 결과를 이용하여 차폐문이 닫힌 경우와 열린 경우의 진료영상 촬영 실습실의 공간선량 분포를 비교 평가하였다. 결과적으로, 차폐문이 열린 경우에도 방사선 발생장치 제어실의 유효선량률은 학생(수시출입자)의 연간 유효선량률 한도(6 mSv/y)를 초과하지 않는다는 것을 알 수 있었다. 하지만, 차폐문이 열려있을 때의 유효선량률이 차폐문이 닫힌 경우에 비해 납유리 앞에서는 약 16배, 차폐문 앞에서는 약 3,000배 더 높기 때문에 실습 중에 차폐문을 닫는 것이 불필요한 방사선 피폭을 크게 줄인다는 것을 알 수 있었다.

Generator 컬럼용 68GeO2 합성 및 68Ga3+의 거동에 관한 연구 (Study on Synthesis of 68GeO2 and Behavior of 68Ga3+ for Generator Column)

  • 김건균;이준영;김상욱;허민구;양승대;박정훈
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.189-192
    • /
    • 2016
  • $^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.

동물병원의 진단용 방사선 발생장치 및 방사선종사자 안전관리 실태 조사 (Radiation safety management for diagnostic radiation generators and employees in animal hospitals in Korea)

  • 안효진;김충현;권영진;김돈환;위성환;문진산
    • 대한수의학회지
    • /
    • 제54권3호
    • /
    • pp.151-157
    • /
    • 2014
  • A nationwide survey on radiation safety management in Korean animal hospitals was conducted. By 2013, 53 radiation generators were registered as veterinary medical devices (41 X-ray generators and 12 computed tomography scanners). Additionally there were six approved laboratories for radiation equipment and protection facility, and five approved laboratories for radiation exposure of employees, respectively. By March 2013, 2,030 out of 3,829 animal hospitals operated radiation-generating devices. Among these devices, 389 (19.2%) out of 2,030 were not labeled with the model name and 746 (36.7%) were not labeled with production dates. Thus, most veterinary X-ray generators were outdated (42.6%) and needed replacements. When periodic inspections of 2,018 animal hospitals were performed after revision of the Veterinarians Act in 2011, the hospitals were found to be equipped with appropriate radiation generators and protection facilities. Among 2,545 employees exposed to radiation at the hospitals, 93.9% were veterinarians, 4.3% were animal nurse technicians, and 18% held other positions. Among 169 employees supervised by administrators, none of those had a weekly maximum operating load that exceeded $10mA{\cdot}min$. This study suggests that the radiation safety management system of animal hospitals was general good.