• Title/Summary/Keyword: Diagnostic Imaging: Radiography

Search Result 232, Processing Time 0.023 seconds

The Comparison of Appropriateness of Abdominal Computed Tomography (CT) and Abdominal Radiography Imaging Modality for Patients with Acute Nontraumatic Abdominal Pain (비외상성 급성 복부 통증 환자에게 시행한 복부 전산화단층촬 영과 복부 단순 촬영의 적정성 비교)

  • Song, Jung-Hup;Ryeom, Hun-Kyu
    • Quality Improvement in Health Care
    • /
    • v.24 no.2
    • /
    • pp.15-25
    • /
    • 2018
  • Purpose: To compare the Appropriateness of abdominal CT to abdominal radiography as an imaging modality in terms of the diagnostic value, medical costs and decision making times for patients presented to the emergency department with nontraumatic abdominal pain. Methods: This study used the records of 530 cases presented to the emergency department(ED) with nontraumatic abdominal pain from February to March 2012. Imaging modalities were categorized into abdominal radiography and CT (radiography first or CT first) or radiography alone or CT alone. The diagnostic value, total medical costs and effect on decision making time of the each imaging modalities were compared. Especially, in retrospective review, to evaluate the predictability of the abdominal radiography, alit was assumed that all the 530 cases performed that exam as initial imaging. Results: Among 530 cases, 255 cases underwent abdominal radiography only, 28 cases underwent abdominal CT only and the remnant 247 cases underwent abdominal CT with plain abdominal radiography. The diagnostic value was higher in the cases with abdominal CT (268/275, 97.5%) than in the cases with plain abdominal radiography (19/255, 7.5%).The number of cases predicted by abdominal radiography only as initial imaging were 39/530 (7.4%). In cases where the patients performed the abdominal CT as the first imaging modality thereby omitting the abdominal radiography, the total diagnostic imaging fee was lower than in cases with plain abdominal radiography first followed by the abdominal CT (277,140 vs. 284,226(mean, Korean Won)). Although diagnostic value of the plain abdominal radiography as first imaging modality was lower than the abdominal CT, Decision making time, average duration of hospital stay was longer and the total medical costs was higher than abdominal CT. Conclusion: As an imaging modality in the ED for patients with acute nontraumatic abdominal pain, plain abdominal radiography is an avoidable procedure when viewed in terms of the diagnostic value and total medical costs and decision making times comparing with abdominal CT.

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries (CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구)

  • Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

Extrahepatic Cholestasis in a Jindo Dog

  • Bae, Jang-Hoon;Lim, Soo-Ji;An, Ji-Young;Son, Seon-Ho;Chang, Jin-Hwa;Kwon, Young-Hang;Ahn, Se-Joon;Song, Geun-Ho;Lee, Young-Won;Choi, Ho-Jung
    • Proceedings of the Korean Society of Veterinary Clinics Conference
    • /
    • 2009.10a
    • /
    • pp.239-239
    • /
    • 2009
  • PDF

Several issues regarding the diagnostic imaging of medication-related osteonecrosis of the jaw

  • Kim, Jo-Eun;Yoo, Sumin;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.273-279
    • /
    • 2020
  • This review presents an overview of some diagnostic imaging-related issues regarding medication-related osteonecrosis of the jaws(MRONJ), including imaging signs that can predict MRONJ in patients taking antiresorptive drugs, the early imaging features of MRONJ, the relationship between the presence or absence of bone exposure and imaging features, and differences in imaging features by stage, between advanced MRONJ and conventional osteomyelitis, between oncologic and osteoporotic patients with MRONJ, and depending on the type of medication, method of administration, and duration of medication. The early diagnosis of MRONJ can be made by the presence of subtle imaging changes such as thickening of the lamina dura or cortical bone, not by the presence of bone exposure. Most of the imaging features are relatively non-specific, and each patient's clinical findings and history should be referenced. Oral and maxillofacial radiologists and dentists should closely monitor plain radiographs of patients taking antiresorptive/antiangiogenic drugs.

Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Jeong, Man-Hee;Im, Eun-Kyung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Clinical application of panoramic radiography With multi-layer imaging software : Case reports (Multi-layer image 소프트웨어를 사용한 파노라마방사선영상의 임상적 활용 : 증례보고)

  • Jeon, Kug Jin;Kim, Jae Hun;Lee, Jeong-Hee;Kim, Young Hyun;Han, Sang-Sun
    • The Journal of the Korean dental association
    • /
    • v.57 no.1
    • /
    • pp.26-33
    • /
    • 2018
  • Panoramic radiography is widely used as a primary radiological diagnosis in dentistry. However, due to the overlapping of anatomical structures, diagnostic capability of panoramic radiography is limited. Recently, panoramic machine equipped with various image processing software has been introduced to improve the diagnostic capability. This study aims to introduce panoramic equipment with multi-layer imaging software that can provide 41 images from anterior to posterior in region of interest, and to report in various clinical applications.

  • PDF

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

The Study about the Positioning Block Artifact in Digital Radiography Environment (Digital Radiography 환경에서 Positioning Block Artifact에 관한 연구)

  • Kim, Byung-Ki;Choi, Jun-Gu;Lee, Jun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • Purpose : In sponge quality of the material in digital radiography environment coating because do position blocks two that do not become coating done positioning blocks two that do not become coating done positioning block and sponge quality of the material to testing bench image artifact's difference compare. Method of study : In digital radiography environment positioning block of different two products same sunshine or effect that image and positioning block artifact gents in image analyze. the target used positioning block 2 when examine hand, rib and examination condition did each differently according to used positioning block. reflex compared picture that do image and verify that examine first time. Result : 1. In sponge quality of the material coating in done product artifact appear. Did not appear in product that do not become coating. 2. Can know coating's existence, that artifact according to radish happens. 3. Quality of the material coating's existence, there was difference of slippage according to radish Conclusion : Quality of the material coating phenomenon that done positioning block thus, it may have to be considered that use after estimate degree that get in image.

  • PDF

Digital Tomosynthesis versus Conventional Radiography for Evaluating Osteonecrosis of the Femoral Head

  • Yun Hwa Roh;Seunghun Lee;Jeong Ah Ryu;Yeo Ju Kim;Yeesuk Kim;Jiyoon Bae
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2026-2033
    • /
    • 2021
  • Objective: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. Materials and Methods: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa. Results: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). Conclusion: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.