• 제목/요약/키워드: Diagnostic Calculation

검색결과 87건 처리시간 0.026초

Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition

  • Kim, Kyung-Tae;Hur, Jin;Kim, Byeong-Woo
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.552-557
    • /
    • 2013
  • This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnetic characteristic. Therefore, many studies on stator-turn faults have been performed by simulation of the finite element method because of its non-linear characteristic. However, this is difficult to apply to on-line fault detection systems because the processing time of the finite element method is very long. Fault-tolerant control systems require diagnostic methods that have simple processing systems and can produce accurate information. Thus analytical modeling of a stator-turn fault has been performed using the winding function theory, and the distributed magnetic characteristics have been analyzed under the fault condition. The proposed analytical model was verified using the finite element method.

라그랑지안 입자모델을 활용한 도시기온 예측기법의 연구 (Study on Urban Temperature Prediction Method Using Lagrangian Particle Dispersion Model)

  • 김석철;윤정임
    • 한국대기환경학회지
    • /
    • 제33권1호
    • /
    • pp.45-53
    • /
    • 2017
  • A high resolution model is proposed for calculating the temperature field of a large city, based upon a Lagrangian particle model. Utilizing the analogy between the heat and mass transport phenomena in turbulent flows, a Lagrangian particle model, originally developed for air pollutant dispersion problems, is adapted for simulating heat transport. In the model conceptual heat particles are released into the atmosphere from the heat sources and move along with the turbulent winds in accordance with the Markov process. The potential temperature assumed to be conserved along with heat particles serves as a tag, so the temperature fields can be deduced from the distribution of particles. The wind fields are constructed from a diagnostic meteorology model incorporating a morphological model designed for building flows. Test run shows the robustness of the modeling system.

Development of the Collective Thomson Scattering System in KAERI

  • 박민;김선호;안찬용;김성규
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.521-521
    • /
    • 2013
  • Collective Thomson scattering (CTS) system is being developed in KAERI based on high power gyrotrons. CTS is a promising diagnostic method to measure fast ion distributions and potentially the fusion product alpha particles in magnetically confined plasmas. By utilizing millimeter-waves from high power gyrotrons as a probing beam, spatially and temporally resolved 1-D ion velocity distributions can be obtained from the scattered radiation with less scattering geometrical constraints. The pulse modulation of gyrotrons enables to separate scattering signal from ECE background noises. The feasibility was assessed with the calculation of spectral density functions under the condition of KSTAR plasmas. Further CTS system requirements are also discussed.

  • PDF

Multimodality and Non-rigid Registration of MRI' Brain Image

  • Li, Binglu;Kim, YoungSeop
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.102-104
    • /
    • 2019
  • Registering different kinds of clinical images widely used in diagnostic and surgery planning. However, cause of tumor growth or effected by gravity, human tissue has plenty of non-rigid deformation with clinically. Non-rigid registration allows the mapping of straight lines to curves. Therefore, such local deformation makes registration more complicated. In this work, we mainly introduce intra-subject, inter-modality registration. This paper mainly studies the nonlinear registration method of 2D medical image registration. The general medical image registration algorithm requires manual intervention, and cost long registration time. In our work to reduce the registration time in rough registration step, the barycenter and the direction of main axis of the image is calculated, which reduces the calculation amount compared with the method of using mutual information.

케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구 (A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency)

  • 신재영;김광호;나완수
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Plant Leave as an Indicator for Pollution by Hydrocarbons and Heavy Metals in Al-Zubair City, Southern Iraq

  • Sajjad W. Jaafar;Sattar J.Al. Khafaji
    • 자원환경지질
    • /
    • 제56권1호
    • /
    • pp.75-85
    • /
    • 2023
  • The potential sources and spatial distribution of heavy metals and polycyclic aromatic hydrocarbons (PAHs) were investigated in the leaf plants of Al-Zubair city. A total of 14 samples of conocarpus lancifolius plant leaf were collected and analyzed for their heavy metals and PAHs content using inductively coupled plasma mass spectrometry (ICP-MS) and a 7890 Agilent capillary gas chromatograph (GC) respectively. Bioaccumulation factor calculation revealed the highest pollution of heavy metals , due to the activity of a petrochemical in the area. The diagnostic ratio of Ant/(Phe+Ant), BaA/BaA+Chr), In/(In+BghiP), Flu/Pyr, FlA/FlA+Pyr), FlA/FlA+Pyr), ∑LMW/∑HMW are commonly used for determining the origin and source of PAHs in various environmental media. The diagnostic ratio indicated the anthropogenic origin. PAHs with five-to-six membered rings were dominant in the plant leaf, which likely results from anthropogenic activities. The leaves of C. lancifolius have a preponderance of high molecular weight PAHs compared to low molecular weight PAHs, indicating a combustion origin (car exhaust, petroleum emissions, and fossil fuel). C. lancifolius leaves are a reliable indication of atmospheric PAHs absorption. The background level of heavy metals in the city (or the near environment) is in the order of Fe > Cu > Ni > Cr. On the other hand, the bioaccumulation in plant leaves showed greater tendencies as follows: Co>Cd>Zn=As>Cu>Mn>Ni>Pb>Cr>Fe. Cobalt showed high bioaccumulation, indicating strong uptake of Co by plant leaves. These findings point to human activity and car emissions as the primary sources of roadside vegetation pollution in Al-Zubair city.

CM 대가 산정방식의 문제점 분석에 대한 연구 -문화예술회관 사례를 중심으로- (Diagnostic Analysis and Influential Factors of CM Fee Estimation)

  • 유병기;정찬영;김재준
    • 한국건설관리학회논문집
    • /
    • 제7권6호
    • /
    • pp.132-140
    • /
    • 2006
  • 1996년 12월 정부에서는 국내 건설산업의 효율성을 높이기 위하여 건설사업관리(CM) 제도를 처음 도입하게 되었다. 그러나, CM의 필요성을 인식하면서도 건설사업 초기단계에서 예상되는 문제점 및 낭비요소의 최소화와 객관적인 기술검토 등을 통한 의사결정능력은 향상되었지만, 발주자의 선택권이 보장되는 다양한 CM 서비스체계 구축과 CM대가 산정에는 많은 문제점이 존재한다. 정부가 발주하는 공공건설사업의 경우 발주자가 산정하는 방식과 CM업체가 산정하는 방식의 차이로 인해서 적정대가를 받지 못해 CM대가 산정이 제대로 이루어지지 않는다. 따라서, 본 논문에서는 실제 공공건설사업 중에서 문화예술회관 사례를 토대로 CM대가 산정에 대해 공사비비율에 의한 방식, 실비정액가산방식의 실제 계약된 금액을 다각도로 분석하여 어떤 불합리성이 존재하며, 아울러 그 원인은 무엇인지에 대해 분석하고자 한다. 이를 토대로 향후 CM의 적정대가 산정기준을 위한 연구의 자료에 일조를 하고자 한다.

뇌의 MR 영상에서 번짐 현상의 명암 값 분석을 통한 백질과 회백질의 추출 및 체적 산출 (Segmentation and Volume Calculation through the Analysis of Blurred Gray Value from the Brain MRI)

  • 성윤창;유승화;송창준;박종원
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제27권8호
    • /
    • pp.815-826
    • /
    • 2000
  • 본 연구는 사람의 뇌에 대한 자기공명영상에서 백질과 회백질을 분리하고 각각의 체적을 산출하기 위한 것이다. 일반적으로 치매나 다운증후군 같은 정신질환의 경우 백질 또는 회백질의 위축으로 인해 체적이 감소하게 되므로, 사람의 뇌에 대하여 백질과 회백질의 체적 산출을 통한 크기의 변화를 추적함으로서 여러 정신질환의 진단 및 조기 발견에 유용하게 이용될 수 있다. 그러나 일정한 두께의 단면을 촬영하여 단일의 명암 값으로 표현하는 자기공명영상기기의 특성상 번짐 현상을 보이는 자기공명영상으로부터 원래의 두께 안에 존재하는 각 성분의 부분체적을 산출할 수 없음으로 인해 백질과 회백질의 체적산출이 현재까지 불가능하였다. 따라서 본 논문에서는 번짐(blurred)을 보이는 자기공명영상에서 번진 명암 값을 해석하는 새로운 알고리즘에 의해 백질과 회백질의 부분체적을 산출하고, 이를 근거로 자기공명영상에서 백질과 회백질을 분리하기 위한 판별값을 결정하였으며, 결정된 판별값에 의해 분리된 영상에서 백질과 회백질의 체적을 산출하였다. 또한 제안된 알고리즘의 검증을 위해 인위적으로 생성된 모델에 알고리즘을 적용하여 산출된 결과를 원래의 모델과 비교하여 보았다.

  • PDF

심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가 (Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography)

  • 조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.