• 제목/요약/키워드: Diagnostic Accuracy

검색결과 1,035건 처리시간 0.03초

구강암의 진단에 사용되어지는 PET/CT: 임상 증례 (THE PET/CT IN THE DIAGNOSIS OF ORAL CANCER: CLINICAL CASES)

  • 김성진;김용각;김철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권2호
    • /
    • pp.178-182
    • /
    • 2005
  • With the development of systemic diagnostic technique in cancer, the diagnostic methods of head and neck region are developing, also. Now, it is usually used computed tomography(CT), magnetic resornance image(MRI) in head and neck cancer and positron emission tomography(PET) is being increased in diagnostic use because of tumor specificity and accuracy. However, CT and MRI show the advantage of showing precise anatomical landmarks, but the disadvantage of these methods is much affecting by anatomical variations and changes. Otherwise, PET presents the imaging of physiologic and biochemical phenomenon and the disadvantage is the difficult differentiation of normal physiologic uptake, the lack of normal anatomical landmarks. PET/CT, the combination of clinical PET and CT imaging in a single unit is introduced recently, and it helps to get more accurate diagnostic interpretation and to improve in evaluating response to therapy, in management of patients with malignant tumors. So, we report the advantages of PET/CT in the diagnosis of oral cancer with review of literatures.

논체질여병증(论体质与病证) (Study on Body Constitution and Disease Symptoms and Signs)

  • 최정식;최명화
    • 대한한의학원전학회지
    • /
    • 제22권4호
    • /
    • pp.241-247
    • /
    • 2009
  • Body constitution research in Korean traditional medicine adopt the diagnosis and treatment theory of "image-differentiation[body constitution differentiation, disease differentiation] in combination with syndrome differentiation diagnostic model and symptoms and signs of herbal property belong to image" as its core, which is key national medical science research project of State Administration of Traditional Chinese Medicine, the project brought up 4 key scientific problem ? body constitution differentiation theory, correlation theory of body constitution and disease, body constitution adjustable theory and symptoms and signs of herbal property belong to image theory. In body constitution pathology, it brought up "correlation between body constitution and symptoms", "differentiation between body constitution and symptoms" which increase the diagnostic level and diagnostic accuracy rate. In the condition of pathology, it obviously has low reliability according to body constitution differentiation, sometimes happen the description not comply with body constitution and disease symptoms, which lead to decrease the clinic diagnostic and treatment level, treatment effect not satisfying too. Now taking 4 key scientific achievement as criterion to illustrate the body constitution and disease symptoms.

  • PDF

Support Vector Machine Based Diagnostic System for Thyroid Cancer using Statistical Texture Features

  • Gopinath, B.;Shanthi, N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.97-102
    • /
    • 2013
  • Objective: The aim of this study was to develop an automated computer-aided diagnostic system for diagnosis of thyroid cancer pattern in fine needle aspiration cytology (FNAC) microscopic images with high degree of sensitivity and specificity using statistical texture features and a Support Vector Machine classifier (SVM). Materials and Methods: A training set of 40 benign and 40 malignant FNAC images and a testing set of 10 benign and 20 malignant FNAC images were used to perform the diagnosis of thyroid cancer. Initially, segmentation of region of interest (ROI) was performed by region-based morphology segmentation. The developed diagnostic system utilized statistical texture features derived from the segmented images using a Gabor filter bank at various wavelengths and angles. Finally, the SVM was used as a machine learning algorithm to identify benign and malignant states of thyroid nodules. Results: The SVMachieved a diagnostic accuracy of 96.7% with sensitivity and specificity of 95% and 100%, respectively, at a wavelength of 4 and an angle of 45. Conclusion: The results show that the diagnosis of thyroid cancer in FNAC images can be effectively performed using statistical texture information derived with Gabor filters in association with an SVM.

Relationship of Somatic Cell Count, Physical, Chemical and Enzymatic Properties to the Bacterial Standard Plate Count in Different Breeds of Dairy Goats

  • Ying, Chingwen;Yang, Cheng-Bin;Hsu, Jih-Tay
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권4호
    • /
    • pp.554-559
    • /
    • 2004
  • The objective of the present study was to investigate the accuracy of mastitis diagnostic indicators for different dairy goat breeds. Biweekly milk samples were collected from individual half mammary gland of seven Saanen and seven Alpine dairy goats in the period of 40 to 120 days in milk. With threshold value set at 2.8 and 3.1 for Alpine and Saanen dairy goats, respectively, log (SPC) offered good sensitivity (0.89, 0.93), specificity (0.88, 0.95), positive predictive value (0.75, 0.85) and negative predictive value (0.95, 0.98) as a mastitis diagnostic tool. The correlations of log (SPC) with milk yield, log (SCC), ALP, LDH, $Na^{+}$, $K^{+}$ and EC were significant in Saanen dairy goats (p<0.05), with the highest correlation coefficient (0.653) existing between log (SPC) and log (SCC). The correlations of log (SPC) with milk yield, milk fat, milk protein, log (SCC), $Na^{+}$, $K^{+}$, EC were significant in Alpine dairy goats (p<0.05), with the highest correlation coefficient (0.416) existing between log (SPC) and log (SCC). There were different best-fit regression equations with different multiple diagnostic indicators for Saanen and Alpine dairy goats. In conclusion, different breeds of dairy goats may have to adapt different mastitis diagnostic parameters for a better diagnosis.

수압측정 방식의 요류검사 진단매개변수의 정확도 평가 (Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure)

  • 김경아;최성수;김성식;김군진;박경순;차은종
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • 제56권2호
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

Diagnostic Value of Human Epididymis Protein 4 Compared with Mesothelin for Ovarian Cancer: a Systematic Review and Meta-analysis

  • Lin, Jia-Ying;Qin, Jin-Bao;Li, Xiao-Yan;Dong, Ping;Yin, Bing-De
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권11호
    • /
    • pp.5427-5432
    • /
    • 2012
  • Background and Purpose: Ovarian cancer is the leading cause of death among gynecologic cancers because of the lack of effective early detection methods. Accuracies of the human epididymis protein 4 (HE4) and mesothelin in detecting ovarian cancer have never been systematically assessed. The current systematic review aimed to tackle this issue. Methods: MEDLINE, EMBASE, and Cochrane databases were searched (September 1995-November 2011) for studies on the diagnostic performances of HE4 and mesothelin in differentiating ovarian cancer from other benign gynecologic diseases. QUADAS items were used to evaluate the qualities of the studies. Meta-DiSc software was used to handle data from the included studies and to examine heterogeneity. All included studies for diagnostic performance were combined with sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratios (DORs) with 95% confidence intervals (CIs), summary receiver operating characteristic (SROC) curves, and areas under the SROC curves (AUC). Results: A total of 18 studies and 3,865 patients were eligible for the final analysis. The pooled sensitivity estimates for HE4 (74.4%) were significantly higher than those for mesothelin (49.3%). The pooled specificity estimates for mesothelin (94.5%) were higher than those for HE4 (85.8%). The pooled DOR estimates for HE4 (26.22) were higher than those for mesothelin (24.01). The SROC curve for HE4 showed better diagnostic accuracy than that for mesothelin. The PLR and NLR of HE4 were 6.33 (95% CI: 3.58 to 11.18) and 0.27 (95% CI: 0.21 to 0.34), respectively. The PLR and NLR for mesothelin were 11.0 (95% CI: 6.21 to 19.59) and 0.51 (95% CI: 0.42 to 0.62), respectively. The combination of the two tumor markers or their combination with CA-125 increased sensitivity and specificity to different extents. Conclusion: The diagnostic accuracy of HE4 in differentiating ovarian cancer from other benign gynecologic diseases is better than that of soluble mesothelin-related protein. Combinations of two or more tumor markers show more sensitivity and specificity.

좌심방 점액종 -2예 보고- (Left atrial myxoma -Two cases report-)

  • 한병선
    • Journal of Chest Surgery
    • /
    • 제19권3호
    • /
    • pp.429-432
    • /
    • 1986
  • Cardiac myxoma is most significant benign tumors constituting nearly 50% of all primary cardiac tumors. Its diagnosis is important because prognosis is excellent by surgical therapy and is usually fatal if unrecognized and untreated. Recently the development of diagnostic procedure and cardiac surgery increased the accuracy of diagnosis and the opportunity of successful treatment. Two cases of left atrial myxoma removed successfully were presented.

  • PDF

이하선 종양에서 세침흡인검사의 유용성 (Efficacy of Fine Needle Aspiration Biopsy in Parotid Gland Tumors)

  • 이창희;이현섭;진성민;이상혁;표정수;손진희
    • 대한두경부종양학회지
    • /
    • 제27권2호
    • /
    • pp.204-209
    • /
    • 2011
  • Background and Objectives : The usefulness of fine needle aspiration biopsy(FNAB) for diagnosis of parotid gland tumors is controversial, because of the generalized belief requiring surgery for most parotid tumors. The aim of this study was to evaluate the efficacy of FNAB for diagnosis in parotid gland tumors. Material and Methods : FNAB was performed in 91 patients who underwent parotid surgery at Kangbuk Samsung Hospital from January 2007 to December 2010. The result of FNAB, 11 malignancies and 75 benign tumors and 5 non-neoplasms were analyzed and compared with the final histopathologic diagnoses. Sensitivity, specificity, accuracy, positive predictive value(PPV), and negative predictive value(NPV) were calculated using final histopathologic diagnosis of the surgical specimen as the standard diagnostic reference for comparative analysis. Results : 86 specimens(94.5%) were suitable for evaluation. We compared the result of FNAB and the final histopathology in 79(89.4%) cases. The sensitivity, specificity, accuracy, PPV, and NPV of FNAB for detecting pleomorphic adenoma was 95.8%, 88.4%, 92.3%, 90.2%, and 95.0%. In Warthin's tumor, results were 86.4%, 94.2%, 92.3%, 82.6%, and 95.6%. Among 11 patients who were diagnosed with malignancy on final histopathologic report, only 3(30%) patients were diagnosed with the same as on FNAB, the other 8 patients were initially diagnosed incorrectly as benign tumors in FNAB. There were no complications related to FNAB. Conclusion : Diagnostic accuracy for FNAB in benign parotid tumors was high. However, in malignant tumors, FNAB shows low diagnostic usefulness compared with benign tumors. FNAB can be effective and safe diagnostic technique for evaluating the benign parotid glands tumors.