• Title/Summary/Keyword: Diagnostic Ability

Search Result 318, Processing Time 0.032 seconds

Diagnostic Role of F-18 FDG PET/CT in the Follow-up of Patients with Colorectal Cancer: Comparison with Serum CEA, CA 19-9 Levels and Computed Tomography (대장암 치료 후 추적 검사로서 F-18 FDG PET/CT의 역할: 혈청 CEA, CA 19-9 및 Computed Tomography와의 진단 성능 비교)

  • Kang, Sung-Min;Song, Bong-Il;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Choi, Kyu-Suk;Jun, Soo-Han
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.120-128
    • /
    • 2009
  • Purpose: Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of CEA, CA 19-9, CT and PET/CT has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to compare the diagnostic ability of PET/CT, tumor marker and CT for recurrence in colorectal cancer patients after treatment. Materials and Methods: F-18 FDG PET/CT imaging was performed in 189 colorectal cancer patients who underwent curative surgical resection and/or chemotherapy. Measurement of serum levels of CEA, CA 19-9 and CT imaging were performed within 2 months of PET/CT examination. Final diagnosis of recurrence was made by biopsy, radiologic studies or clinical follow-up for 6 months after each study. Results: Overall sensitivity, specificity of PET/CT was 94.7%, 91.1%, while those of serum CEA were 44.7% and 97.3%, respectively. Sensitivity and specificity were 94.2%, 90.4% for PET/CT and better than those of combined CEA and CA 19-9 measurement(52.1%, 88.5%) in 174 patients measured available both CEA and CA 19-9 data. In 115 patients with both tumor markers and CT images available, PET/CT showed similar sensitivity but higher specificity(92.9%, 91.3%) compared to combination of tumor markers and CT images(92.9%, 74.1%). Conclusion: PET/CT was superior for detection of recurred colorectal cancer patients compared with both CEA, CA 19-9, and even with combination of both tumor markers and CT. Therefore PET/CT could be used as a routine surveillance examination to detect recurrence or metastasis of colorectal cancer.

Effectiveness of Esophageal Ultrasonography Surgical Therapy of Esophageal Cancer (식도암 수술에서 식도내시경초음파(EUS) 진단의 효용성)

  • Jung, Jae-Seung;Lee, Sung-Ho;Cho, Seong-Joon;Son, Ho-Sung;Sun, Kyung;Kim, Kwang-Taik;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.91-97
    • /
    • 2003
  • With the advent of stage-adapted multimodal regiments for esophageal malignancy, accurate staging has become of utmost importance. Endoscopic ultrasono graphy(EUS) i.: a diagnostic method for the local staging of esophageal cancer, in particular for T and N evaluation. The aim of this study was to examine the diagnostic efficacy of the EUS and to evaluate the relation between prognosis and EUS findings. Material and Method : We reexamined the cases of 88 consecuitive patients who underwent transthroacic esophagectomy and cervical esophagogastrostomy for esophageal cancer from January 1991 to July 2001 We compared EUS findings, histological results and outcomes. Result : There were 83 male(94.3%) and 5 female. Median age was 61.3 years old. Overall staging accuracy were 59.0% for T staging and 76.0% for N staging, In early T staging group, the accuracy was 74.9% except 74 stage. However significant differences were not found in the ability of EUS-determined T-stage and N-Stage to predict survival. Multivariate analysis showed EUS-stage to predict survival. Conclusion : EUS provides a high degree of accuracy in assessing both T and N parameters in staging esophagal cancer. EUS should be performed in all patients with esophageal cancer, not only for staging before therapy, but also as a valuable method of determining prognosis.

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.

The Korean Practice Parameter for the Treatment of Attention - Deficit Hyperactivity Disorder(II) - Diagnosis and Assessment - (주의력결핍 과잉행동장애 한국형 치료 권고안(II) - 진단 및 평가 -)

  • Cheon, Keun-Ah;Kim, Ji-Hoon;Kang, Hwa-Yeon;Kim, Bung-Nyun;Shin, Dong-Won;Ahn, Dong-Hyun;Yang, Su-Jin;Yoo, Han-Ik;Yoo, Hee-Jeong;Hong, Hyun-Ju
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 2007
  • Probably the three most important components to a comprehensive evaluation of patients with attention-deficit hyperactivity disorder (ADHD) are the clinical interview, the medical examination, and the completion and scoring or behavior rating scales. Teachers and other school personnel are often the first to recognize that a child or adolescent might have ADHD, and often play an important role in the help-seeking/referral process. A diagnostic evaluation for ADHD should include questions about ADHD symptoms, other problems including alcohol and drug use, family history of ADHD, prior evaluation and treatment for ADHD. Screening interview or rating scales as well as interviews should be used. When it is feasible, clinicians may wish to supplement these components of the evaluation with objective assessments of the ADHD symptoms, such as psychological tests. These tests are not essential to reaching a diagnosis, however, or to treatment planning, but they may yield further information about the presence and severity of cognitive impairments that could be associated with some cases of ADHD. Screening for intellectual ability and academic achievement skills is also important in determining the presence of comorbid developmental delay or loaming disabilities. The number and type of symptoms required for a diagnosis of ADHD vary depending on the specific subtype. To receive a diagnosis of ADHD, the person must be experiencing significant distress or impairment in daily functioning, and must not meet criteria for other mental disorders which might better account for the observed symptoms such as mental retardation, autism or other pervasive developmental disorders, mood disorders, anxiety disorders. This report aims to suggest a practice guideline of assessment and diagnosis for children and adolescents with ADHD in Korea.

  • PDF

The Relationship between Hair Zinc and Lead Levels and Clinical Features of Attention-Deficit Hyperactivity Disorder

  • Shin, Dong-Won;Kim, Eun-Ji;Oh, Kang-Seob;Shin, Young-Chul;Lim, Se-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.25 no.1
    • /
    • pp.28-36
    • /
    • 2014
  • Objectives : The goal of this study was to examine the association between zinc and lead level and symptoms of attention-deficit hyperactivity disorder (ADHD) among Korean children. Methods : A total of 89 clinic-referred children participated in the study (ADHD group=45, control group=44). The participants were 5-15 years old, and were mainly from urban areas of Seoul, Korea. ADHD was diagnosed using the Kiddie-Schedule for Affective Disorders and Schizophrenia-Present and Lifetime Version. We excluded children with a comorbid psychiatric disorder, medical illness requiring medication, or a prior history of taking ADHD medication. In order to evaluate the severity of ADHD symptoms, parents' Korean ADHD Rating Scale (K-ARS) was used. The ADHD diagnostic system (ADS) was used for evaluation of the severity of inattention and impulsivity. All participants completed the intelligence test and hair mineral analysis. Multiple regression analysis was used to examine the effect of hair zinc and lead levels on the K-ARS and ADS. We measured the predictive ability of the zinc and lead levels using logistic regression analysis. Results : The lead level explained the score for omission errors, commission errors, and response time SD in visual ADS in the ADHD group (adjusted $R^2$=.243, p<.01, adjusted $R^2$=.362, p<.01, and adjusted $R^2$=.275, p<.01), the score for omission errors of auditory ADS in ADHD group (adjusted $R^2$=.407, p<.01) and the entire group (adjusted $R^2$=.292, p<.01). Zinc was significantly explanatory for the K-ARS scores for the entire group (adjusted $R^2$=.248, p<.001) and the ADHD group (adjusted $R^2$=.247, p<.05). Conclusion : These findings suggest a possible role of zinc and lead in ADHD. Lead concentration in hair samples affected the ADS scores, and this was more prominent in children with ADHD. Children with ADHD had a lower zinc concentration in their hair, and the zinc concentration in hair showed negative correlation with the K-ARS score.

Development of a Clinical Decision Support System Utilizing Support Vector Machine (Support Vector Machine을 이용한 생체 신호 분류기 개발)

  • Hong, Dong-Kwon;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.661-668
    • /
    • 2018
  • Biomedical signals using skin resistance have different characteristics according to stress diseases. Biological diagnostic devices for diagnosing stress diseases have been developed by using these characteristics, and devices have been developed so that the signals measured by the skin storage meter can be easily analyzed. Experts in the field will look directly at the output signal to determine the likelihood of any stress disorder. However, it is very difficult for a person to accurately determine whether a person to be measured has a stress disorder by analyzing a bio-signal measured by each person to be measured, and the result of the judgment is very likely to be wrong. In order to solve these problems, we implemented the function of determining the signal of a stress disorder by using the machine learning technique. SVM was used as a classification method in consideration of low computing ability of measurement equipment. Training data and test data were randomly generated for each disease using error range 5 based on 13 diseases. Simulation results showed more than 90% decision accuracy. In the future, if the measurement equipment is actually applied to the patients, we can retrain the classifier with the newly generated data.

Use of $^{18}F$-FDG PET/CT in Second Primary Cancer (이차성 원발암에서의 $^{18}F$-FDG PET/CT의 이용)

  • Choi, Joon-Young;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.185-193
    • /
    • 2007
  • This review focuses on the use of $^{18}F-FDG$ PET/CT to evaluate second primary cancers. The emergence of a second primary cancer is an important prognostic factor in cancer patients. The early detection of a second primary cancer and the appropriate treatment are essential for reducing the morbidity and mortality associated with these tumors. Integrated $^{18}F-FDG$ PET/CT, which can provide both the metabolic and anatomic information of a cancer, has been shown to have a better accuracy in oncology than either CT or conventional PET. The whole body coverage and high sensitivity of $^{18}F-FDG$ PET/CT along with its ability to provide both metabolic and anatomic information of a cancer make it suitable for evaluating a second primary cancer in oncology. Whole body $^{18}F-FDG$ PET/CT is useful for screening second primary cancers with a high sensitivity and good positive predictive value. In order to rule out the presence of a second primary cancer or an unexpected metastasis, further diagnostic work-up is essential when abnormal findings indicative of a second primary cancer are found on the PET/CT images. PET/CT is better in detecting a second primary tumor than conventional PET.

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF