• 제목/요약/키워드: Diagnosis of performance

검색결과 1,555건 처리시간 0.047초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

비소세포 폐암 환자의 2차 치료로서 Gemcitabine과 Vinorelbine의 병합 요법의 효과 (Phase II Study of Gemcitabine and Vinorelbine as a Combination Chemotherapy for the Second-Line Treatment of Nonsmall Cell Lung Carcinoma)

  • 이은주;하은실;박상훈;허규영;정기환;정혜철;이승룡;김제형;이상엽;신철;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제59권5호
    • /
    • pp.510-516
    • /
    • 2005
  • 배 경 : 새로운 항암제의 사용으로 비소세포 폐암에서 1차 항암 치료의 효과는 많이 향상 되었지만 많은 환자에서 치료 중 혹은 치료 후에 폐암이 진행하거나 재발되고 있다. 최근 환자의 체력 및 영양 상태의 향상으로 폐암의 진행 및 재발 후에도 신체 수행 상태(performance status)가 양호하여 2차 항암 치료의 대상 환자가 늘어나는 추세이다. 그러나 아직까지 표준화된 2차 항암 치료가 없는 실정으로 gemcitabine과 vinorelbine의 병합 요법은 비교적 다른 기전의 독성을 보여 병합 요법으로서의 가능성을 높여 주었다. 이에 저자들은 1차 항암 요법에 반응을 보이지 않거나 재발한 진행성 비소세포 폐암 환자를 대상으로 gemcitabine과 vinorelbine 병합 요법을 시행하여 치료 반응율, 생존율 및 독성에 대해 연구하였다. 대상 및 방법 : 2000년 12월부터 2003년 7월까지 고려대학교 의료원에 내원하여 비소세포 폐암으로 확진 받은 환자 중 진단 당시 IIIB, IV병기로 platinum을 기반으로 docetaxel 혹은 paclitaxel의 2제 복합 항암 요법을 1차 치료로 시행한 환자 중 진행하거나 재발한 환자들을 대상으로 gemcitabine과 vinorelbine 병합 요법의 치료 반응율, 생존율 및 독성을 분석하였다. 결 과 : Vinorelbine과 gemcitabine 병합 항암화학 요법은 총 215회가 시행 되었고, 환자당 시행된 평균값은 3.6회였다. 주요 반응에 해당하는 관해율은 10%였다. 1년 생존율은 32.9% 였으며, 생존 중앙값은 10.1개월이었다. 관해 지속 기간 중앙값은 3.8개월이었다. 대부분에서 경도의 오심과 구토, 탈모증이 관찰되었으며 WHO grade 3의 오심, 구토는 2예(3%)였으며, grade 4의 오심, 구토는 없었다. Grade 3 백혈구 감소가 33.3%, grade 4가 11.7%로 비교적 흔히 발생하였다. 호중구 감소가 동반된 폐렴으로 사망이 1예 보고되었다. 결 론 : Platinum을 기반으로 하는 1차 항암 치료 후 재발하거나 진행한 비소세포 폐암 환자에서 gemcitabine과 vinorelbine 병합 항암 요법은 비교적 효과적이고 안전한 항암 치료법으로 사료된다.

PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교 (A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT)

  • 이승재;박훈희;안샤론;오신현;남궁혁;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • PET/CT 검사의 사용 초기에 CT는 주로 감쇠보정(Attenuation Correction: AC)의 목적으로 사용되어졌지만, CT의 성능이 향상됨으로써 조영제를 이용한 CT검사를 진단에 반영하여 보다 진보된 진단적 가치를 가질 수 있게 되었다. 조영제의 사용이 없이도 CT를 판독할 수 있지만 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 있어서 조영제의 사용은 판독자로 하여금 판독을 매우 용이하게 하는 도움을 줄 수 있다. 하지만, 그동안 PET/CT검사 시 조영제가 감쇠보정에 영향을 줄 수 있다는 논쟁으로 이견이 많았다. 40-140 keV 정도의 낮은 엑스선을 이용하는 CT영상에 비하여, 조영제를 사용한 CT영상에서는 조영제로 인해 감쇠가 많이 되지만 511 keV의 에너지를 가진 감마선은 조영제로 인해 거의 영향을 받지 않게 되고 이로 인해 감쇠보정 시 과보정을 하게 되어 PET영상에서 오류를 나타낼 수 있다는 의견이 보고되기도 하였다. 이와는 반대로 조영제가 감쇠보정에 과대평가를 가져올 수 있다는 의견과 과보정으로 인한 표준화섭취계수에 변화의 가능성은 있으나 결정적인 영향을 미치지 않는다는 의견도 제시되었다. 본 연구에서는 조영제의 영향이 SUV에 어떠한 영향을 미치는지에 대해서만 비교 평가하였다. 2007년 12월에서 2008년 6월 사이에 본원에서 PET/CT 검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 진행성 암 환자 30명을 대상으로 하였으며, DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하여, 각각의 환자는 조영제를 사용하지 않은 CT를 시행한 후 PET영상을 얻었고 그 후, 조영제를 사용한 CT검사를 하였다. 각각의 CT정보로 감쇠보정을 실시, 종류별로 PET영상을 획득하여, 각 영상에 동일한 관심영역(Region of Interests : ROIs)을 설정 후, SUV를 비교 하였다. 얻어진 두 가지 결과 값의 정량 분석의 비교를 위해서 대응표본 T-검정 (Paired t-test)을 사용하였다. 검사를 시행한 30명의 환자에게서 폐, 간, 심장의 $SUV_{max}$ 값과 $SUV_{mean}$값을 측정하여 총 180개 영역을 분석하였다. 조영제를 사용하기 전과 후를 비교하였을 때, 측정한 거의 모든 영역에서 조영 후의 $SUV_{max}$$SUV_{mean}$가 상승하였고 통계적으로도 유의한 것으로 나타났다(p value<0.05). 심장 영역에서 조영 전 보다 조영 후의 $SUV_{mean}$값이 증가된 것으로 나타났지만, 통계적으로 유의하게 나타나지는 않았다. 조영제를 사용한 CT영상의 SUV값이 과보정되어, 조영제를 사용하지 않은 CT의 SUV 보다 높게 나왔으나 기존의 보고된 논문에서는 이와 같은 결과는 실제 임상 판독에 있어서 큰 영향을 미치지 않는다고 보고되어 있다. 그러나 원발성병변의 진행을 알아보는 과정에서는 SUV의 작은 변동도 분명 영향을 줄 수 있으므로 간 영역과 같이 SUV의 변동이 다른 영역에 비해 상대적으로 큰 영역에서는 수치의 변화에 대한 주의가 요구 될 것으로 사료된다.

  • PDF

대학병원 응급실 내 1급 응급구조사의 업무와 직무만족도 (The Work and Job Satisfaction of Paramedics in the Emergency Room of University Hospitals)

  • 이옥희
    • 한국응급구조학회지
    • /
    • 제15권1호
    • /
    • pp.47-63
    • /
    • 2011
  • Purpose : This research is to examine the work and job satisfaction of paramedics in the emergency room of university hospitals. This research is done to provide basic data needed for establishing work realms of paramedics in hospitals and to enhance their degree of satisfaction. Methods : Research questionnaire survey was conducted on 141 paramedics working in the emergency room of 32 university hospitals from August 24, 2010 to September 30, 2010 through direct visits and telephone interviews or email to explain the purpose of this research and assurance of confidentiality of responses on the questionnaires. As the tool for the degree of job satisfaction, 'The Index of Work Satisfaction' developed by Slavitt, et al(1978) and revised and supplemented by Soon-shim Kim and Hye-ran Kwon(2002) was used. The collected data were analyzed by evaluating frequency, percentage, mean, standard deviation, t-test and ANOVA, Cronbach's $\alpha$ by using SPSS WIN 18.0 program. Results : 1. Investigating the work and role of paramedics in the emergency room of university hospitals, electrocardiogram(EKG) was found to be highest with $\alpha$ was widely used with the rate of patient evaluation and test area. In the medical treatment for patients area, cardiopulmonary resuscitation(CPR) with 95%(134 persons) and ventilation assistance through ambu bagging(BVM) with 95%(134 persons) were found to be high. $\alpha$ were performed. In the role within the hospital and other areas, a member of CPR team in the hospital accounted for 78%(110 persons). 2. In the measurements of the job satisfaction of paramedics working at university hospitals, the total mean score was 2.91. The mean score in each question area indicated: section on job 3.48, autonomy 3.05, interaction 3.01, organizational demand 2.85, working conditions 2.67, salaries 2.40. This result obviously demonstrates the work of paramedics itself was most satisfied but the salaries were most dissatisfied. 3. In the measurements of the job satisfaction of paramedics working at university hospitals, job satisfaction based on the general characteristics showed significant difference in age (F=6.547, p=.002), gender (F=4.436, p=.000) marital status (F=-3.270, p= .001), religion (F=2.041, p= .043), motive for application (F=3.603, p= .015), and salary (F=6.658, p= .000). 대학병원 응급실 내 1급 응급구조사의 업무와 직무만족도 The Journal of the Korean Society of Emergency Medical Technology Vol. 15 (1) 63 4. In the measurements of the job satisfaction of paramedics working at university hospitals, job satisfaction based on the working environmental characteristics showed significant difference in total number of paramedics (F=3.779, p= .012), form of employment (F=5.601, p= .001), existence or non-existence of intention to change jobs (F=-4.037, p= .000). Conclusion : The work of paramedics in the emergency room of university hospitals consists of lots of treatment processes after specialized diagnosis and performance of professionally subdivided works. However, current legislation does not reflect such circumstances to which paramedics are exposed; thus, it should be considered for further revision and modification. The degree of job satisfaction of paramedics in the emergency room of university hospitals was high but low in salaries and working conditions were the weak points. The measures to enhance their degree of job satisfaction should be taken though improvement of labor conditions such as consideration of the rate of increase in salaries, compensation for overtime work, providing rest areas, improvement of current employment system, and conversion of temporary employees into regular employees.

암환자 인식에 관한 연구 - 간호사ㆍ의사를 중심으로

  • 조인향
    • 호스피스학술지
    • /
    • 제2권1호
    • /
    • pp.58-74
    • /
    • 2002
  • This paper constitutes a descriptive investigation and used a structured questionnaire to investigate nurses' and doctors' recognition of cancer patients. The subjects were extracted from the medical personnel working at the internal medicine, the surgery ward, the obstetrics and gynecology department, the pediatrics department, the cancer ward, and the emergency room of five general hospitals located in Seoul and Gyeonggi Province. The research lasted from August, 2001 to September 2001. Total 137 nurses and 65 doctors were included and made out the questionnaires directly distributed by the investigator. The study tool was also developed by the investigator and consisted of such items as the demographic and social characteristics, the medical personnel's recognition degree of cancer and cancer patients, their recognition of the management of cancer patients, and their participation in a hospice. The results were analyzed using the SPSS Window program in terms of technological statistics, ranks, t-test, and ANOVA. The reliability was represented in Cronbach' α=.75. The nurses' and doctors' recognition degree of cancer and cancer patients had an overall average of 3.86 at the 5 point-scale. The items that received an average of 4.0 or more included 'Medical personnel should explain about the cancer cure plans to the cancer patient and his or her family', 'A patient whose case has been diagnosed as a terminal cancer should be notified of it, 'If I were a cancer patient, I would want to get informed of it,' and 'Cancer shall be conquered whenever it is'. In the meantime, the items that received an average of 3.0 or less was 'My relationship with the cancer patient's family has gotten worse since I announced his or her impending death.' And according to the general characteristics and the difference test, the recognition degree of cancer and cancer patient was high among the subgroups of nurses, females, married persons, who were in their 30s, who had a family member that was a cancer patient, and who received a hospice education. The biggest number of the nurses and doctors saw 'a gradual approach over several days'(68.8%) as a method to tell a cancer patient about his or her cancer diagnosis or impending death. Those who usually tell tragic news were the physician in charge(62.8%), the family members or relatives(32.1%) and the clergymen(3.8%) in the order. The greatest number of them recommended a cancer patient's home as the place where he or she should face death because they thought 'it would stabilize his or her mentality'(91.9%) while a number of them recommended the hospital because they 'should give the psychological satisfaction to the patient'(40%) or 'should try their best until the last moment of the patient's death'(30%). A majority of the medical personnel regarded 'smoking or drinking' and 'diet' as the causes of cancer. The biggest symptom of a cancer patient was 'pain' and the pain management of a cancer patient was mostly impeded by the 'excessive fear of drug addiction, tolerance to drugs and side effects of drugs' by medical personnel, the patient, and his or her family. The most frequently adopted treatment plan of a terminal cancer patient was 'to do whatever the patient or his or her family wants' to resort to a hospice' and 'to continue active treatment efforts' in the order. The biggest reasons why a terminal cancer patient went to see a doctor were 'pain alleviation' 'control of symptoms other than pain(intravenous supply)' and 'incapability of the patient's family' in the order. Terminal cancer patients placed their major concern in 'spiritual(religious) matter' 'emotional matters' their family' 'existence' and 'physical matters' in the order. 113(58.5%) of the whole medical personnel answered they 'would recommend' an alternative treatment to a terminal cancer patient mostly because they assumed it would 'stabilize the patient's mentality.' Meanwhile, 80(41.5%) of them chose 'not to recommend it mostly due to the unverified effects and high cost of it(78.7%). A majority of them, I. e. 190(94.1%) subjects said they 'would recommend' a hospice to a terminal cancer patient mostly because they thought it would help the patient to 'mentally prepare'(66.6%) Only 17.3% of them, however, had received a hospice education, most of which was done through the hospital duty education(41.4%) and volunteer training(34.5%). The follows are results of this study: 1. The nurses and the doctors turned out to be still passive and experience confusion in dealing with a cancer patient despite their great sense of responsibility for him or her. 2.Nurses and Doctors realize the need of a hospice, but an extremely small number of them participate in a hospice education or performance. Thus, a whole recognition of a hospice should be changed, for which purpose a hospice education for nurses and doctors should be provided. 3.Terminal cancer patients preferred their home to a hospital as the place to face their impending death because they felt it would bring 'mental stability.' And most of nurses and doctors think it would be unnecessary for them to be hospitalized just for control of their symptoms. Accordingly a terminal cancer patient can be cared at home, and a home hospice care needs to be activated.

  • PDF

Survival Results and Prognostic Factors in T4 N0-3 Non-small Cell Lung Cancer Patients According to the AJCC 7th Edition Staging System

  • Arslan, Deniz;Bozcuk, Hakan;Gunduz, Seyda;Tural, Deniz;Tattli, Ali Murat;Uysal, Mukremin;Goksu, Sema Sezgin;Bassorgun, Cumhur Ibrahim;Koral, Lokman;Coskun, Hasan Senol;Ozdogan, Mustafa;Savas, Burhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2465-2472
    • /
    • 2014
  • Background: The American Joint Committee on Cancer (AJCC) published a new staging system ($7^{th}$ edition) in 2009. In our study, we evaluated the survival results and prognostic factors among T4 local advanced non-small cell lung cancer (LA-NSCLC) patients in a large heterogeneous group, in accordance with this new system. Materials and Methods: We retrospectively evaluated the files of 122 T4 N0-3 M0 LA-NSCLC patients, identified according to the new staging system, treated at two centers between November 2003 and June 2012. Variables correlating with univariate survival at p<0.20 were later included in multivariate Cox regression analysis. Here, selection of relevant predictors of survival was carried out in accordance with the likelihood ratio formula with p<0.05 regarded as significant. Results: The median age was 60 and the median follow-up period was 17.4 months. Median overall survival (OS) was 18.3 months, the 1 year overall survival (OS) rate was 72%, and the 5 year OS rate was 28%. Statistically significant predictors of survival were (p<0.20) ECOG-PS (Eastern Cooperative Oncology Group Performance Status), age, T4 factor subgroup, stage and primary treatment in OS univariate analysis. On multivariate analysis for OS ECOG-PS (p=0.001), diagnostic stage (p=0.021), and primary treatment (p=0.004) were significant. In the group receiving non-curative treatment, the median OS was 11.0 months, while it was 19.0 months in the definitive RT group and 26.6 months in the curative treatment group. There was a significant difference between the non-curative group and the groups which had definitive RT and curative operations (respectively p<0.001 and p=0.001) in terms of OS, but not between the groups which had definitive RT and curative operations. The median event free survival (EFS) rate was 9.9 months, with rates of 46% and 19% at 3 and 5 years, respectively. On univariate analysis of EFS rate with ECOG-PS, weight loss and staging, statistical significance was found only for thorax computerized tomography (CT)+18F-fluorodeoxy-glucose positron emission tomography-CT (PET-CT) use, stage and primary treatment (p<0.20). In multivariate analysis with EFS, only the primary treatment was statistically significant (p=0.001). In the group receiving non-curative treatment, the median EFS was 10.5 months while in the curative operation group it was 14.7 months. When all the primary treatment groups were taken into consideration, grade III/IV side effect swas observed in 57 patients (46.6%). Esophagitis was most prominent among those that received definitive radiotherapy. Conclusions: Independent prognostic factors among these 122 heterogeneous LA-NSCLC T4 N0-3 M0 patients were age at diagnosis, ECOG-PS, stage and primary treatment, the last also being a significant prognostic indicator of EFS. Our findings point to the importance of appropriate staging and a multidisciplinary approach with modern imaging methods in this patient group. In those with T4 lesions, treatment selection and the effective use of curative potential should be the most important goal of clinical care.

Training Program to Raise Consciousness Among Adolescents for Protection Against Skin Cancer through Performance of Skin Self Examination

  • Balyaci, Ozum Erkin;Kostu, Nazan;Temel, Ayla Bayik
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권10호
    • /
    • pp.5011-5017
    • /
    • 2012
  • Background: Overexposure to sunlight in childhood and the adolescent period and associsated sunburns significantly increase the risk of skin cancer in adulthood. In Turkey, the incidence of skin cancer in the general population is 0.8%. The incidence is 0.6% and the mortality rate is 0.4% for men, while these rates are 1.0% and 0.7%, respectively, for women. If skin cancer is found early, its treatment is facilitated. Therefore, personal skin examination is important for early diagnosis. Objectives: Our aim was to determine the effects of training for raising consciousness among adolescents to protect against skin cancer by influencing skin self examination behavior. Method: This quasi experimental intervention study was conducted between February and April 2012 in Izmir. The study population consisted of students attending $6^{th}$, $7^{th}$ and $8^{th}$ classes of a primary school (n:302). No sampling was performed. Data were collected with a form developed by the researchers based on the literature. The first part of form is aimed to determine demographic characteristics of adolescents (3 questions) and their risk status of skin cancer (6 questions). The second part was prepared for skin cancer risks of adolescents (8 questions) and indications of skin cancer (12 questions). The last part was intended to determine their knowledge about skin self examination (4 questions) and behavioral stages of skin self examination (1 question). Data collection was achieved with a questionnaire form in three phases. In the 1st phase, data about demographic characteristics of students, risk status of skin cancer, knowledge level of skin cancer and behavior stages were collected. In the $2^{nd}$ phase, skin self examination training based on the transtheoretical model was performed within the same day just after obtaining preliminary data. In the $3^{rd}$ phase, adolescents were followed up three times to establish the efficacy of the training (on the $15^{th}$ day after training program and at end of the $1^{st}$ and $2^{nd}$ months). Follow-up data were evaluated by questioning skin self examination performing behavior stages through electronic mail. Results: Half of the adolescents (50.5%) are male, and 58.4% of them are 13 years old with a mean age of $12{\pm}1.15$ years. About 29.4% of adolescents had brown hair color, 37.9% had brown/hazel eye color, 29.4% had white skin, and 47.2% had fewer than 10 moles in their body. The pretest mean score on knowledge level about risks of skin cancer was found to be $4.19{\pm}1.96$, while the post-test mean score was $6.79{\pm}1.67$ (min:0, max:8).The pretest mean score about indications of skin cancer was $7.45{\pm}3.76$, while the post-test mean score was $10.7{\pm}2.60$ (min:0, max:12). The increases were statistically significant (p<0.05). The behavior "I do not perform skin self examination regularly in every month and I do not think to perform it in the next 6 months" was reduced from 52.8 to 35.5% after training. Conclusion: The training program organized to raise consciousness among adolescents for protection against skin cancer increased the knowledge level about risks and indications of skin cancer and it also improved the behavior of performing skin self examination.

CIPP 모형 기반 직업능력개발훈련교사 자격연수(양성과정) 진단 및 개선 방안 연구 (Diagnosis and Improvements Plan Study of CIPP Model-based Vocational Competency Development Training Teacher Qualification Training (Training Course))

  • 배광민;우혜정;최명란;윤관식
    • 직업교육연구
    • /
    • 제36권2호
    • /
    • pp.95-121
    • /
    • 2017
  • 직업능력개발훈련교사는 직업능력개발훈련교사 양성을 위한 훈련과정을 수료하는 등 대통령령으로 정하는 기준을 갖추어 고용노동부 장관으로부터 직업능력개발훈련교사 자격증을 발급받아야 한다. 이에 국내 유일의 직업능력개발훈련교사 자격연수를 담당하고, 노동시장에 양산하는 역할을 수행하는 H대학교의 교육성과는 직업능력개발훈련에 많은 영향을 미친다고 할 수 있다. 본 연구는 CIPP모형에 기초하여 직업능력개발훈련교사 자격연수 교육운영의 실태분석을 통한 문제점을 파악하고, 나아가 자격연수 교육의 개선방안을 제시하는데 목적을 두고 진행하였다. 연구목적 달성을 위해 직업능력개발훈련교사 양성교육 이수자를 대상으로 교직훈련과정에 대한 현황을 파악하고, 개선방안을 도출하기 위한 설문조사를 실시하고 173부의 결과를 활용하였으며, 설문결과에 대한 세부현황 파악과 심층 분석을 위해 8인의 교육 대상자를 선정하여 인터뷰를 병행하였다. 연구결과 상황요인에서 교육과정의 목표, 교육자원 등에서 긍정적인 답변이 도출되었다. 반면 학습자와 사회적 요구를 반영한 교육과정에 대한 부정적 의견이 있었다. 투입요인에서는 교육목표와 훈련요구 항목에서 긍정의견이 도출되었으나 학습자들의 교육목표 성취여부는 부정적 의견이 많았다. 또한 온라인콘텐츠 교육의 부정적 의견이 많았다. 과정요인에서는 수업관련 부분, 학습자 출결관리, 기관지원 등에서 긍정평가가 높았으나, 자격연수 종합평가에 대해 부정의견이 도출되었으며 학습기간 부족에 따른 학습자 부담이 주요 원인으로 나타났다. 산출요인에서는 교육과정의 현업적용가능성에서 산업직종별 교육훈련을 담당하는 훈련교사들에게 교육학 및 직업훈련 운영과 관련된 학습이 편성된 자격연수에 긍정적인 의견이 도출되었다. 그러나 학습 성취도에서 교육수준 대비 학습시간과 학습 집중도문제, 교수자의 커뮤니케이션 등 부정적 의견도 있었다. 연구결과를 기초로 직업능력개발훈련교사 자격연수 교육운영의 개선 방안을 제언하면 다음과 같다. 첫째, 직업능력개발훈련교사 자격연수 평일과정 연수일정의 탄력적 운영이 요구된다. 둘째, 수요자 중심의 온라인 교육과정 개선을 강구할 필요가 있다. 셋째, 지방거주 교육이수자들의 자격연수 접근성을 모색할 필요가 있다. 넷째, 자격연수 합격자들에 대한 사전 교육지원이 진행될 필요가 있다. 마지막으로 자격연수 수료자에 대한 사후 관리가 필요하다.

국민건강보험 발전방향 (Future Direction of National Health Insurance)

  • 박은철
    • 보건행정학회지
    • /
    • 제27권4호
    • /
    • pp.273-275
    • /
    • 2017
  • It has been forty years since the implementation of National Health Insurance (NHI) in South Korea. Following the 1977 legislature mandating medical insurance for employees and dependents in firms with more than 500 employees, South Korea expanded its health insurance to urban residents in 1989. Resultantly, total expenses of the National Health Insurance Service (NHIS) have greatly increased from 4.5 billion won in 1977 to 50.89 trillion won in 2016. With multiple insurers merging into the NHI system in 2000, a single-payer healthcare system emerged, along with separation policy of prescribing and dispensing. Following such reform, an emerging financial crisis required injections from the National Health Promotion Fund. Forty years following the introduction of the NHI system, both praise and criticism have been drawn. In just 12 years, the NHI achieved the fastest health population coverage in the world. Current medical expenditure is not high relative to the rest of the Organization for Economic Cooperation and Development. The quality of acute care in Korea is one of the best in the world. There is no sign of delayed diagnosis and/or treatment for most diseases. However, the NHI has been under-insured, requiring high-levels of out-of-pocket money from patients and often causing catastrophic medical expenses. Furthermore, the current environmental circumstances of the NHI are threatening its sustainability. Low birth rate decline, as well as slow economic growth, will make sustainment of the current healthcare system difficult in the near future. An aging population will increase the amount of medical expenditure required, especially with the baby-boomer generation of those born between 1955 and 1965. Meanwhile, there is always the problem of unification for the Korean Peninsula, and what role the health insurance system will have to play when it occurs. In the presidential election, health insurance is a main issue; however, there is greater focus on expansion and expenditure than revenue. Many aspects of Korea's NHI system (1977) were modeled after the German (1883) and Japanese (1922) systems. Such systems were created during an era where infections disease control was most urgent and thus, in the current non-communicable disease (NCD) era, must be redesigned. The Korean system, which is already forty years old, must be redesigned completely. Although health insurance benefit expansion is necessary, financial measures, as well as moral hazard control measures, must also be considered. Ultimately, there are three aspects that we must consider when attempting redesign of the system. First, the health security system must be reformed. NHI and Medical Aid must be amalgamated into one system for increased effectiveness and efficiency of the system. Within the single insurer system of the NHI must be an internal market for maximum efficiency. The NHIS must be separated into regions so that regional organizers have greater responsibility over their actions. Although insurance must continue to be imposed nationally, risk-adjustment must be distributed regionally and assessed by different regional systems. Second, as a solution for the decreasing flow of insurance revenue, low premium level must be increased to an appropriate level. Likewise, the national reserve fund (No. 36, National Health Insurance Act) must be enlarged for re-unification preparation. Third, there must be revolutionary reform of benefit package. The current system built a focus on communicable diseases which is inappropriate in this NCD era. Medical benefits must not be one-time events but provide chronic disease management. Chronic care models, accountable care organization, patient-centered medical homes, and other systems that introduce various benefit packages for beneficiaries must be implemented. The reimbursement system of medical costs should be introduced to various systems for different types of care, as is the case with part C (Medicare Advantage Program) of America's Medicare system that substitutes part A and part B. Pay for performance must be expanded so that there is not only improvement in quality of care but also medical costs. Moreover, beneficiaries of the NHI system must be aware of the amount of their expenditure through a deductible payment system so that spending can be profiled and monitored. The Moon Jae-in Government has announced its plans to expand the NHI system; however, it is important that a discussion forum is created so that more accurate analysis of the NHI, its environments, and current status of health care system, can take place for reforming NHI.

원격의료서비스 수용요인의 구조적 관계 실증연구 (Structural Relationships Among Factors to Adoption of Telehealth Service)

  • 김성수;류시원
    • Asia pacific journal of information systems
    • /
    • 제21권3호
    • /
    • pp.71-96
    • /
    • 2011
  • Within the traditional medical delivery system, patients residing in medically vulnerable areas, those with body movement difficulties, and nursing facility residents have had limited access to good healthcare services. However, Information and Communication Technology (ICT) provides us with a convenient and useful means of overcoming distance and time constraints. ICT is integrated with biomedical science and technology in a way that offers a new high-quality medical service. As a result, rapid technological advancement is expected to play a pivotal role bringing about innovation in a wide range of medical service areas, such as medical management, testing, diagnosis, and treatment; offering new and improved healthcare services; and effecting dramatic changes in current medical services. The increase in aging population and chronic diseases has caused an increase in medical expenses. In response to the increasing demand for efficient healthcare services, a telehealth service based on ICT is being emphasized on a global level. Telehealth services have been implemented especially in pilot projects and system development and technological research. With the service about to be implemented in earnest, it is necessary to study its overall acceptance by consumers, which is expected to contribute to the development and activation of a variety of services. In this sense, the study aims at positively examining the structural relationship among the acceptance factors for telehealth services based on the Technology Acceptance Model (TAM). Data were collected by showing audiovisual material on telehealth services to online panels and requesting them to respond to a structured questionnaire sheet, which is known as the information acceleration method. Among the 1,165 adult respondents, 608 valid samples were finally chosen, while the remaining were excluded because of incomplete answers or allotted time overrun. In order to test the reliability and validity of the assessment scale items, we carried out reliability and factor analyses, and in order to explore the causal relation among potential variables, we conducted a structural equation modeling analysis using AMOS 7.0 and SPSS 17.0. The research outcomes are as follows. First, service quality, innovativeness of medical technology, and social influence were shown to affect perceived ease of use and perceived usefulness of the telehealth service, which was statistically significant, and the two factors had a positive impact on willingness to accept the telehealth service. In addition, social influence had a direct, significant effect on intention to use, which is paralleled by the TAM used in previous research on technology acceptance. This shows that the research model proposed in the study effectively explains the acceptance of the telehealth service. Second, the research model reveals that information privacy concerns had a insignificant impact on perceived ease of use of the telehealth service. From this, it can be gathered that the concerns over information protection and security are reduced further due to advancements in information technology compared to the initial period in the information technology industry, and thus the improvement in quality of medical services appeared to ensure that information privacy concerns did not act as a prohibiting factor in the acceptance of the telehealth service. Thus, if other factors have an enormous impact on ease of use and usefulness, concerns over these results in the initial period of technology acceptance may become irrelevant. However, it is clear that users' information privacy concerns, as other studies have revealed, is a major factor affecting technology acceptance. Thus, caution must be exercised while interpreting the result, and further study is required on the issue. Numerous information technologies with outstanding performance and innovativeness often attract few consumers. A revised bill for those urgently in need of telehealth services is about to be approved in the national assembly. As telemedicine is implemented between doctors and patients, a wide range of systems that will improve the quality of healthcare services will be designed. In this sense, the study on the consumer acceptance of telehealth services is meaningful and offers strong academic evidence. Based on the implications, it can be expected to contribute to the activation of telehealth services. Further study is needed to assess the acceptance factors for telehealth services, such as motivation to remain healthy, health care involvement, knowledge on health, and control of health-related behavior, in order to develop unique services according to the categorization of customers based on health factors. In addition, further study may focus on various theoretical cognitive behavior models other than the TAM, such as the health belief model.