• 제목/요약/키워드: Diagnosis Related Groups

검색결과 326건 처리시간 0.026초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

정신건강의학과 외래 환자 중 자살 고위험 집단의 심리적 특성 : MMPI-2-RF를 이용하여 (Psychological Characteristics of Psychiatric outpatients with High Suicide Risk : Using MMPI-2-RF)

  • 남지수;김대호;김은경
    • 정신신체의학
    • /
    • 제28권1호
    • /
    • pp.8-19
    • /
    • 2020
  • 연구목적 본 연구에서는 정신과 외래 환자 중 자살 고위험 집단인 자살 사고, 자살 시도, 비자살적 자해 및 일반 정신과 환자 집단의 감별 시 MMPI-2-RF가 변별 도구로써 활용될 수 있는지 알아보고자 하였다. 방 법 모든 대상자는 한양대학교 구리병원에 정신과적 진료를 내원한 환자로, 정신건강의학과 전문의로부터 DSM-5에 근거한 진단을 받았고, 이들의 의무기록을 후향적으로 검토하여 네 집단(자살 사고, 자살 시도, 비자살적 자해, 통제집단으로 일반 정신과 환자)으로 분류하였다. 총 112예가 분석에 포함되었다. 수집된 자료를 분석하기 위해 기술 통계 분석, 성별을 공변인으로 한 다변량 공분산분석(MANCOVA)를 통해 집단 간 차이를 알아보고자 하였다. 결 과 연구 결과, 비임상군인 대학생을 대상으로 한 기존 선행 연구와 마찬가지로, 임상군인 정신과 외래 내원 환자들 중에서도 자살 고위험군이 저위험군에 비해 높은 정서적/내재화 문제(EID), 무력감/무망감(HLP), 자살/죽음 사고(SUI), 의기소침(RCd), 인지적 증상 호소(COG), 냉소적 태도(RC3), 역기능적 부정 정서(RC7)와 부정적 정서성/신경증(NEGE-r) 점수를 보였다. 하지만 자살에 대한 위험성이 높은 환자들을 자살 사고, 자살 시도, 비자살적 자해를 시도하는 개인들 총 세 집단으로 나누어 분석하였을 때, 세 집단 모두를 변별할 수 있는 변인은 관찰되지 않았다. 다만, 자살 시도 집단 및 비자살적 자해 집단이 일반 정신과 환자 집단에 비해 높은 행동화/외현화(BXD), 반사회적 행동(RC4), 공격성(AGG) 등을 보였으나, 자살 사고 집단과 일반 정신과 환자 집단 사이에는 유의한 차이가 없었다. 결 론 본 연구는 MMPI-2-RF가 임상군인 정신과 외래 내원 환자들 중 자살 위험이 높은 환자들을 자살사고, 자살 시도, 비자살적 자해 세 집단으로 구분했을 때, 이 세 집단을 변별할 수 있는 유용한 진단적 도구로써 기능할 수 있는지 확인해보고자 하였으나, 세 집단 모두를 변별해주는 요인은 관찰되지 않았다. 이에, 세 집단 간변별에는 MMPI-2-RF가 진단적으로 유용하지 않을 것으로 시사된다. 다만, 자살 사고 집단에서는 차이가 나타나지 않았으나 자살 시도 및 비자살적 자해 집단에서는 통제군인 일반 정신과 환자들에 비해 높은 공격성과 행동화가 나타나, 자살 사고가 실제 자살 시도로 이행되는 과정에서 이러한 지표들이 위험성을 판단할 수 있는 조기변별 지표로서 기능할 수 있을 것으로 보인다.

종합병원(綜合病院)의 간호행위양상(看護行爲樣相)에 따른 간호원가(看護原價) 산정(算定)에 관(關)한 연구(硏究) (A Study on Accounting for Nursing Cost by Korean Diagnosis Related Groups (K - DRGs))

  • 오효숙
    • 한국보건간호학회지
    • /
    • 제3권2호
    • /
    • pp.5-46
    • /
    • 1989
  • The current medical payment Insurance Rates in Korea stipulate charges for medical treatment by the doctor, pharmaceutist, medical technician and maternity nurse. But unfortunately didn't specify those charges for nursing done by the professional nurse. Only basic nursing fee is accounted insufficiently in current medical insurance fee schedule. therefore, Being face with covering entire people by medical insurance by 1991, It seems that the problems pertaining to operating the hospital and medical insurance system would be incessantly expanded in that no mention is made of medical charges rendered by major medical producer service in the current system, For that reason, this study made an attempt to clarify the importance the professional nursing puts of the current medical payment. The purpose of this study was to accounting nursing fee which diveded into the current medical fee schedule. (Method) 1. Data collection; Importance and difficulties in nursing activities was conducted in 'S' National University Hospital. Total nursing activities were selected 72 items which included direct care and indirect care. This study was conducted to evaluating the degree of importance and difficulties according to nursing activities through questionnaire to 204 RN. and so relative difficulties (acuity) were computered because the nursing cost level of each nursing service was differently established by the equivalent coefficient according to degree of relative difficulty and time required. 2. Calculation of cost according to nursing activities; After 47 nursing activities were selected in General surgery nursing units, calculation of nursing cost was as follows Cost of Nursing activity = (relative difficulty X Average hourly wage and benefits of nurse) + material cost of nursing -t- Average nursing administration cost So, Calculated cost by nursing activities was compared to current non-insured and insurance rate. 3. Calculation of nursing cost by K - DRG ; Total of 578 patients who were hospitalized in General Surgery units from January to March 1988 ware classified by K - DRG After estimation of total nursing cost based on the K-DRG, verified the appropriateness of basic nursing fee in medical insurance rate (Results) 1. Analysis of degree of importance and difficulties were 4.16 and 3.67 based on 5 point scale. This score were judged that it is worthy specifying the nursing fee 2. The nursing cost of 47 nursing service items in general surgery patients showed that the average cost of nursing activity was \1374.5 and The lowest cost was \217 of 'oral administration nursing' item, The highest cost was \11,025 of 'saline enematill clear' item 3. The result of comparison between the calculated cost by nursing activities against the current non-insured and insurance rate showed that 13 items(27.7%) involved to payment of insurance rate, 9 items(19.1%) involved to non-insured rate, remainder 25 items (53.2%) were not charged anywhere of total 47 nursing activities 4. When calculated cost by nursing activities was 100. current insurance rate was 62.3, non-insured rate was 176.6. Therefore this showed that most of non-insured rate were higher than calculated nursing cost. The insurance rate, however, were lower than it. Reim-bursement was imputed to non-insured patients. So the current rate system became estrainged from cost system. When Remainder 25 items of nursing activities compared' to \1390 of daily basic nursing fee per patient belonged to payment as a insurance fee schedule, basic nursing fee schedule was 1-2% of calculated cost of nursing activities. Therefore it showed that nursing fee was not counted adequately in it. 5. Nursing cost by K-DRG estimated in chart review based on counting number of nursing activities and length of stay The result showed that average amount of total nursing cost was \183828.1 Comparison of nursing cost calculated by K- DRG and basic nursing fee schedule showed that only 12.3% of nursing cost was charged (Conclusion) From the above research result, It is fact that nursing prime cost should be estimated more accurately and included adequately in current medical payment system. The payment system of nursing activities should be introduced not only nursing activities of drug administration and injection fee belonged to insurance fee schedule but also most nursing activities belonged not to mekical fee schedule. Even if introducing payment system of nursing activities, It should be estimated scientific method of Accounting nursing cost So nurses could offer nursing care of good quality, thereby they could make a great contribution not merely to the convalescence of the patient but to the promotion of the people's health.

  • PDF

기계 판막을 이용한 라스텔리 수술의 장기 성적 (Long Term Results of Rastelli Operation with a Mechanical Valve)

  • 최세훈;김관창;곽재건;김창영;이정렬;김용진;노준량;김웅한
    • Journal of Chest Surgery
    • /
    • 제39권12호
    • /
    • pp.900-905
    • /
    • 2006
  • 배경: 선천성 심장병에서 라스텔리 수술은 일반적으로 동종 혹은 이종의 조직판막을 이용하게 되며 이 경우 장기적으로 재수술이 요구된다. 반면 기계판막을 이용하여 라스텔리 수술은 보고가 많지 않으며 이번 연구는 이들 환자에서의 장기 성적을 알아보고자 하였다. 대상 및 방법: 1990년 1월부터 1992년 7월까지 기계판막을 이용한 라스텔리 수술을 받은 20명의 환자 중 조기 사망 1명을 제외한 19명의 환자를 대상으로 하였다. 기저질환으로는 교정된 대혈관전위증 4예, 대혈관전위증 2예, 심실중격결손을 동반한 폐동맥폐쇄증 9예, 총동맥간 2예, 양대혈관우심실기시증에 동반된 폐동맥협착증 2예였다. 수술 당시의 평균 연령은 $4.6{\pm}3.4$년이며, 남녀비는 1.11:1이었다. 사용한 판막으로는 Carbomedics 16예, Bjork-Shiley 3예였으며 평균 크기는 $17{\pm}2mm$였다. 평균 추적관찰 기간은 $12.8{\pm}2.7$년이었다. 결과: 19명 중 15명은 판막 도관에 대한 재수술을 받았으며, 재수술까지의 평균 기간은 $5.3{\pm}4.7$년이었다. 재수술 시에는 전부 조직판막을 사용하였다. 5 yr freedom from reoperation은 53%, 10 yr freedom from reoperation은 37%였다. 항응고 치료는 와파린과 아스피린, 다이피리다몰을 사용하였으며 PT INR수준은 1.5에서 2.0으로 유지하였고, 심각한 수준의 출혈성 부작용이나 색전에 의한 부작용은 발생하지 않았다. 술 후 3년을 기준으로 이전과 이후의 판막도관의 실패원인에서 차이를 보였다. 3년 이전에 재수술을 받은 환자군(총 6예)을 분석하였을 때, 전부에서 판막 자체의 움직임에 제한이 있었으며, 그 중 3예에서는 혈전에 의한 움직임 장애, 3예에서는 pannus 또는 fibromyxoid plaque에 의한 움직임 장애였다. 반면, 3년 이후에 재수술을 시행받은 9예에서는 1예를 제외하고 전부에서 도관 협착이 있었으며 판막 움직임은 정상이었다. 결론: 기계판막을 이용하여 라스텔리 수술의 경우 장기 성적을 좋게 하기 위해서 초기에는 엄격한 항응고 치료가 요구되며 장기적으로는 도관재질의 개선을 요구된다. 일부 환자에서는 10년 이상 특별한 문제없이 사용이 가능하였다.

소아 용혈성 빈혈 환자에서 원인에 따른 임상적 분석 (A Clinical Study on Childhood Hemolytic Anemia According to Etiological Classification)

  • 권해식;강정철;원성철;오승환;유철주
    • Clinical and Experimental Pediatrics
    • /
    • 제46권9호
    • /
    • pp.883-888
    • /
    • 2003
  • 목 적 : 용혈성 빈혈은 진단방법의 발전과 관심의 증대로 해마다 빈도가 증가하고 있다. 저자들은 지난 15년간 용혈성 빈혈로 진단받은 환자들을 토대로 원인에 따라 적혈구 내적 요인과 외적 요인으로 나누어 임상적 양상을 후향적으로 조사하여 차이를 분석하였다. 방 법 : 1987년 1월에서 2002년 5월까지 연세대학교 의과대학 세브란스병원 소아과에 내원하여 용혈성 빈혈을 진단 받은 58명의 환자들을 대상으로 진단 당시 연령, 성별, 증상, 혈색소, 망상구 수, 백혈구 수, 혈소판 수, 총 빌리루빈과 간접 빌리루빈, 비장비대 여부, Coombs' 반응, Alanine aminotransferase/Aspartate aminotransferase, 혈액요소질소 및 크레아티닌 치, 소변 검사, 치료 방법, 재원일수, 수혈 횟수를 분석하였다. 결 과 : 전체 환자 58명 중 적혈구 내적 결함에 의한 용혈성 빈혈(group I)이 21례(36%)로 유전성 구상적혈구증 19례, glucose-6-PD 결핍증 2례가 있었고, 적혈구 외적 결함에 의한 용혈성 빈혈(group II)은 34례(59%)로 용혈성요독증후군 9례, 온항체에 의한 자가면역 7례, 한랭 항체에 의한 자가면역 6례, 약물에 의한 경우 4례, 신생아 용혈성 질환 3례, 기계적 손상에 의한 경우 2례, 전신성 홍반성 낭창 2례, 악성종양 1례였다. 미분류는 3례(5%)였다. 성별 분포는 남자 : 여자의 비율이 group I은 2.5 : 1(15명 : 6명), group II는 1 : 1.5(15명 : 22명)이었다. 두 군간의 임상 양상을 비교 분석하였을 때 통계적으로 의미 있게(P<0.05) 차이를 보인 항목으로는 진단 시 혈색소 치, 혈액요소 질소 및 크레아티닌 치, 비장비대 여부로 나타났다. 치료에 있어서 내적 요인에서는 비장절제술만 시행한 경우가 대부분이었으며 외적 요인에서는 스테로이드, 복막투석, 면역글로불린 등 다양한 치료가 시행되었다. 결 론 : 소아 용혈성 빈혈 환자에서 원인에 따른 임상 양상을 비교 분석하여 본 결과, 외적 요인으로 인한 경우 진단 당시 혈색소 치가 더 낮고, 혈액요소질소 및 크레아티닌 치가 더 높은 것이 의미 있게 관찰되었으며, 내적 요인으로 인한 경우 비장비대가 의미 있게 더 많은 것으로 나타났다.

흉부외상에 의한 인공호흡기치료 환자에서 발생한 폐렴의 임상분석 (Clinical Analysis of Ventilator-Associated Pneumonia in Chest Trauma)

  • 윤주식;오봉석;류상우;장원채
    • Journal of Chest Surgery
    • /
    • 제41권6호
    • /
    • pp.736-741
    • /
    • 2008
  • 배경: 흉부 외상 환자에 있어서 폐렴은 가장 흔한 감염증이며, 진단 및 치료의 발전에도 불구하고 이환율과 치사율을 높이는 매우 심각한 합병증이다. 본 연구는 흉부 외상 환자 중 인공호흡기 치료를 하였던 환자에서 폐렴의 임상 양상을 분석하고 그 원인 인자를 파악하고자 하였다. 대상 및 방법: 2001년 1월부터 2006년 12월까지 흉부 외상에 의해 인공호흡기 치료를 시행한 78명의 환자를 대상으로 하였다. 대상 환자 중 폐렴이 발생한 38예를 I군으로,폐렴이 발생하지 않은 40예를 II군으로 나누어 비교 분석하였다. 각 군의 병원 도착시 혈역학적 소견 및 이학적 소견, 혈액학적 소견, 외상의 원인, 흉부 외상의 형태 및 그 정도, 동반 외상, 기저 질환, 인공호흡기 이용 기간, 중환자실 입원 기간 그리고 사망률 등을 후향적으로 조사하였다. 결과: 대상 환자는 남자 57명, 여자 21명이었으며, 평균 연령은 $48.3{\pm}19.9$세였다. 흉부외상에 의해 인공호흡기 치료를 시행한 환자의 48.7%에서 외상 후 페렴이 발생하였고, 사망률은 I군에서 21.0%, II군에서 2.5%로 II군에서 현저하게 높았다. 내원시 혈역학적 소견 상 수축기 혈압이 90 mmHg 이하의 쇼크 상태로 인해 수축촉진약(inotropics)을 사용한 경우는 I군에서 24예(63.1)로 II군의 10예(25%)보다 유의하게 많았으며(p=0.001), C-Reactive Protein(CRP) 치는 I군에서 $11.3{\pm}7.8$으로 II군의 $6.4{\pm}7.3$에 비해 유의하게 높았다(p=0.006). 인공호흡기 이용기간 및 중환자실 입원 기간은 I군에서 각각 17.4일, 21.7일로 II군의 6.5일, 9.7일에 비해 유의하게 길었다(p<0.001). 결론: 외상 후 폐렴의 발생은 인공호흡기 이용 기간 및 중환자실 입원 기간이 긴 환자에서 많이 발생하였으며 그외 내원시 측정한 CRP 치가 높은 경우, 쇼크 상태로 인해 수축촉진약(inotropics)를 사용한 경우에 많이 발생하였다. 흉부 외상 환자의 치료 시 이런 요인들을 고려한다면 폐렴의 예방 및 치료에 도움이 될 것으로 생각된다.

장티브스에 관한 임상적 관찰 (Clinical review of Typhoid Fever Patients)

  • 최정신
    • 대한간호학회지
    • /
    • 제6권1호
    • /
    • pp.60-71
    • /
    • 1976
  • The author reviewed the medical records of 96 typhoid fever patients who were diagnosed, admitted, and treated at Sea grave Memorial Hospital from January 1 , 1973 through August 31, 1975. Diagnosis was determined by clinical observation, aerology and bacteriology, eighty patients were treated medically, the remaining 16 patients required surgical intervention. The following results were obtained: 1) The age distribution of the patients revealed that 33.3% wert between 10 and 19 years old 21.9% were between 20 and 29, and 19.8% were between 30 and 39. The majority of patients were from these more active age groups. Male to female sex ratio was 1.3 : 1 2) Seasonal distribution was observed. Most illness occurred in the summer and autumn month 5. 3) 84. 3%of the patients came from farm families. 4) Duration between onset and admission averaged 16.0 days. The group without compilations was admitted after an average of 15. 1 days; The group with complications was ad-matted after an average of 19.4 days. 5) Methods of treatment before admission were as follows: 10.4% at medical clinics, 61, 5% at pharmacies (antibiotics 47.9%, other. drugs 13.5%), 7.3% by herb medications, 20.8% had no treatment. 6) Main clinical symptoms were as follows: fever 93.8%, headache 47.9%, abdominal pain 47.9%, chills 38.5%, cough 36.5%, general weakness 26.0%, nausea e vomiting 24.0% and generalized pain 21.9%. 7) Temperature of patients on admission: 22.9% were 39f or more, 67.6% were between 37℃ and 38℃, and 9.4% were 37℃ or less. 8) Occurrence of intensional bleeding after onset of disease averaged 9.3 days; perforation occurred at an average of 19. 1 days. 9) Interval between onset of major complication and surgical intervention averaged 2.8 days. 10) Among the 68 patients who underwent the bacteriological test the positive rate was 44.1% (30). The positive ,ales to, each separate culture method were as follows: 20.4% in the blood culture, 40.4% in the stool culture and 6.7% in the urine culture. Among these bacteriological positive patients 15 patients had a negative results or less than 160 titer of vidal reaction. 11) The initial vidal test of the total group showed a counts of 160 titer or more in 60.4% and less than 160 titer in 39.6%, 12) W. B. C. Counts in the uncomplicated group indicated that 32.5% were 6,000/㎣ or less, 47.5% were between 6,000 and 10,000, arid 20.0% were 10,000/㎣ or more. In the complicated group, 37.6% were 6,000/㎣ or less, 25,0% were 6,000-10,000/㎣ and 37.6% were 10,000/㎣ or more. 13) Duration of hospital stay of the patients averaged 6.4 days in the uncomplicated group and 12.7 days in the complicated group. 14) Subdiaphragmatic free air simple X-ray was found in 91.7% of the perforated cases. 15) Duration of antibiotic therapy until an febrile state was attained averaged 4.8 days in the uncomplicated group and 6.5 days in the complicated group. 16) Operative procedures were as follows: one layer simple closure of their perforation with or without debasement in 56.3%, drainage only in 6.3%, small bowel resection with primary anastomosis in 18.8% , externalization in 6.3%, cholecystectomy in 6.3%, The clinical findings of this study suggest the following recommendations. According to Top's report; 1% of typhoid fever patients treated with chlorarnphenicol and 2% of patients treated with other drugs become chronic carriers. Therefore, importance should be given to the strict control of these carriers. Immunization, improvement of sanitation and living standards are all needed for the prevention and treatment of disease, but a more serious problem is a lack of knowledge on the part of patients and their families. Thus it is most urgent to enlighten the citizens about the transmission and hygiene related to contagious disease. Legal restriction of sale of antibiotics at drug stores without a physician's prescription is an urgent matter for public health administrators. An even more important nursing responsibility is the reemphasis on health education both in the clinical setting and in the home.

  • PDF

90년대 이후 미국과 일본 소아치과학회지 게재논문의 분야별 분포에 관한 비교 연구 (A COMPARATIVE STUDY ON THE THEMATIC DISTRIBUTION OF THE ARTICLES PUBLISHED IN THE JOURNAL OF THE AMERICAN ACADEMY OF PEDIATRIC DENTISTRY AND THE JAPANESE SOCIETY OF PEDIATRIC DENTISTRY)

  • 염정현;김신;정태성
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.539-554
    • /
    • 2002
  • 우리나라의 소아치과학과 큰 연관성을 가진 일본과 미국, 두 나라의 최근 소아치과학적 연구동향을 살펴보기 위하여 일본 소아치과학회지 (이하 JJPD)와 미국 소아치과학회지 (이하 PD)를 대상으로 1991년부터 2000년까지 양 학술지에 게재된 논문의 서지학적인 정보를 수집하여 시대별, 주제별 분포 및 각 연구주제에 있어서의 변화양상을 비교, 분석하여 다음과 같은 결과를 얻었다: 1. JJPD에는 총 869편, PD에는 672편으로, JJPD에 약 30% 정도 더 많은 논문이 게재되었다. 2. JJPD와 PD 모두 증례보고가 원저에 비하여 1/4 정도의 비율을 보였다. 3. 전신질환 관련 연구는 JJPD와 PD 모두에서 가장 높은 비율을 보였으며, 치아우식증, 수복재 연구 또한 양자 모두에서 비교적 높은 비율을 보였다. 4. 약물진정과 생화학적 행동연구는 PD에서 높은 비율을 보인 반면, JJPD에서는 상당히 낮은 비율을 보였다. 행동연구 및 행동조절은 JJPD의 게재 논문수가 PD보다 2배 정도 더 많았다. 5. 치아우식증, 치아우식증의 예방 지역치과의료 조사, 수복 치료, 수복재 연구, 치수치료, 부정교합의 원인과 치료, 국소 마취 및 신경조직 연구, 구강병리와 소수술, 외상성 손상은 양자 간의 논문 수에 있어서 유의한 차이가 없었다. 6. JJPD의 경우 치과용 장비가, PD의 경우 수복재 연구가 유의한 증가추세를 보였다. 7. JJPD의 경우에는 국소마취 및 신경조직 연구, 치아우식증의 예방, PD의 경우 수복치료가 유의한 감소추세를 보였다.

  • PDF

주요 우울장애와 준임상적 우울증에서의 감정표현불능증 (Alexithymia in Major Depressive Disorder and Subclinical Depression)

  • 김석주;유승희;김성연;김동욱;조인희;조성진
    • 정신신체의학
    • /
    • 제15권2호
    • /
    • pp.100-106
    • /
    • 2007
  • 연구목적 : 본 연구는 주요 우울장애 환자들과 준임상적 우울증 환자들의 감정표현불능증 정도를 조사하기 위해 시행되었다. 방법 : 지역사회에 거주하는 386명(남/여=148/238, 평균 연령 : $43.0{\pm}13.9$, 연령 범위 : 19~79)이 연구에 참여했다. 구조화된 임상면담(Structured Clinical Inteview for DSM-IV, SCID)를 이용하여 주요 우울장애 및 기타 1축 정신질환을 진단했다. 우울증상를 평가하기 위해 역학연구센터 우울척도(the center for epidemiologic studies-depression scale, CES-D)를 자가 작성하게 했다. 감정표현불능증은 토론토 감정표현불능증 척도(Toronto alexithymia scale, TAS)로 평가했다. 주요 우울장애의 병력이 없는 이 중 SCID에서 경도 우울장애가 있거나, CES-D 점수가 16점 이상인 경우를 준임상적 우울증으로 정의했다. 주요 우울장애군, 준임상적 우울증군, 정상 대조군 세군으로 나누어 TAS 총점과 각 요인별 점수를 비교했다. 결과 : 전체 386명 중, 38명(9.8%)이 DSM-IV 주요 우울장애의 진단 기준에 부합하는 병력이 있었고, 57명(14.8%)이 준임상적 우울증군으로 분류되었다. 각 군간 TAS 총점($F_{2,383}=14.0$, p<0.01), 요인 1(감정인식의 장애) ($F_{2,383}=23.4$, p<0.01), 요인 2(감정표현의 장애)($F_{2,383}=7.8$, p<0.01)에 차이가 있었다. TAS 요인 3(외부지향적 사고)는 유의한 차이가 없었다($F_{2,383}=1.8$, p=0.16). 주요 우울장애군과 준임상적 우울증군은 모두 대조군에 비해 TAS 총점, 요인 1, 요인 2의 점수가 높았다(모두 p<0.01). 반면, 주요 우울장애군과 준임상적 우울증군은 TAS 총점 및 각 요인 점수에서 유의한 차이가 없었다. 결론 : 준임상적 우울증 환자는 우울증상이 없는 대조군에 비해 감정표현불능증이 더 심했다. 한편, 주요 우울장애와 준임상적 우울증은 감정표현불능증에서 유의한 차이가 없었다. 이러한 결과는 감정표현 불능증이 주요 우울장애 뿐아니라 준임상적 우울증과도 관계있음을 시사한다.

  • PDF