• 제목/요약/키워드: Diagnosis Method

검색결과 4,991건 처리시간 0.033초

SRAM 기반의 FPGA 연결선을 위한 고장 진단 알고리듬 개발 (An Efficient Diagnosis Algorithm for SRAM-Based FPGA Interconnects)

  • 김용준;김지혜;전성훈;강성호
    • 대한전자공학회논문지SD
    • /
    • 제41권4호
    • /
    • pp.113-122
    • /
    • 2004
  • 본 논문에서는 FPGA 연결선을 위한 고장 진단 방안을 제안한다. 제안된 고장 진단 방안은 FPGA의 연결선에 존재하는 모든 고장을 진단한다. 또한 이는 최신의 FPGA 장치인 Xilinx Virtex FPGA에 적용이 가능하다. 제안된 고장 진단 방안은 기존의 고장 진단 방안에 비하여 훨씬 짧은 시간동안 고장 진단을 수행한다.

The Use of Support Vector Machines for Fault Diagnosis of Induction Motors

  • Widodo, Achmad;Yang, Bo-Suk
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.46-53
    • /
    • 2006
  • This paper presents the fault diagnosis of induction motor based on support vector machine (SVMs). SVMs are well known as intelligent classifier with strong generalization ability. Application SVMs using kernel function is widely used for multi-class classification procedure. In this paper, the algorithm of SVMs will be combined with feature extraction and reduction using component analysis such as independent component analysis, principal component analysis and their kernel (KICA and KPCA). According to the result, component analysis is very useful to extract the useful features and to reduce the dimensionality of features so that the classification procedure in SVM can perform well. Moreover, this method is used to induction motor for faults detection based on vibration and current signals. The results show that this method can well classify and separate each condition of faults in induction motor based on experimental work.

  • PDF

UHF 이중대역법을 이용한 GIS PD 분석 (GlSPD Analysis Using UHF Dual-Band Method)

  • 이상화;최재구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

지역급전 제어소의 무인변전소와 송전망 통합진단 시스템에 관한 연구 (A Study on the Integrated Diagnosis System for Unmanned Substation and Transmission Network in Local Control Center)

  • 이흥재;임찬호;최기훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.516-518
    • /
    • 1995
  • This paper presents an integrated fault diagnosis expert system for power systems. The proposed system diagnoses various faults occurred in both substations and transmission lines even in the case that substation fault is spreaded over the network. To cope with this problem, A meta-inference method is proposed. This scheme shares same the data structure with the pre-developed intelligent operational aid expert system installed in a practical sub-control center, without modification. This advanced integrated diagnosis system is developed using a low cost personal computer owing to the special modular programming technique. Case studies show a promising possibility of the proposed method.

  • PDF

수치해석을 이용한 액체용 Ejector 성능진단 기법 (Diagnosis of Liquid Ejector Performance with Numerical Analysis)

  • 김범신;장석원;정훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.856-860
    • /
    • 2000
  • Liquid ejector is widely used for power plant water pump, marine pump and transportation of solid materials. It has high working confidence and simple configuration. However, It is not easy to know performance degradation of ejectors in field. When the geometry of ejector is complicate, the diagnosis of faults is required more skillful method without disassemble. This paper gives numerical method to predict cause of $45^{\circ}$ slurry suction ejector performance degradation.

  • PDF

고전압 절연재료의 결함진단을 위한 부분방전측정 (The Measurement of Partial Discharge to Diagnose Defects in High-Voltage Insulating Materials)

  • 이정빈;정우성;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.134-138
    • /
    • 1994
  • According to request of insulating materials for high-voltage, recently we make effort not only to develop diagnostic skills of aging state but also to discover defects in insulating material in the early. Especially, partial discharge has been actively studied as a non-destructive diagnosis technique and very useful method. Because the method of partial discharge measurement has damages less than other conventional diagnosis technique. In this paper, the characteristics of partial discharge was investigated and studied on many samples with voids. In order to adapt as a practical diagnosis technique, it is studied on the characteristics of partial discharge and insulation breakdown in the high voltage. We suggest that partial discharge measurement can be used in order to diagnose defects in high-voltage insulation materials.

한방 맥파 분석을 위한 디지틸 시스템 설계 (Digital System for Analyging Oriental Pulse Signals Designed)

  • 이준영;서현우;이정환;김정훈;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.544-544
    • /
    • 2000
  • From ancient times. the diagnosis method of the oriental medicine has been Performed by curing diseases by means of rectifying and adjusting the unbalance in the Physiological function of the five viscera and the six bowels of a human body. Diseases have been diagnosed by the condition of blood circulation that cycles a human body through blood vessels by dint of the vitality of the heart, Based on such a systematic pulse diagnosis method, the article presents parameters that will be beneficial to clinical application on the basis of its analysis of the filtering for eliminating noises from pulse signals inputted from sensor group the digital hardware dealing with signals necessary for recognition algorithm. and the structure of diagnosis algorithm and components of pulse waveform.

  • PDF

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

유압실린더 힘 제어계의 인-프로세스 서보밸브 마모진단에 관한 연구 (In-Process Diagnosis of Servovalve wear in Hydraulic Force Control Systems)

  • 김성동;전세형;장영배
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.22-30
    • /
    • 2009
  • An in-process method of diagnosing the spool wear of hydraulic servovalves was explored. The diagnostic method discussed in this paper is for force-control hydraulic servo systems. The key principle used is that pressure sensitivity of a servovalve drops as the valve spool wears out so that it is possible to determine the spool condition by monitoring pressure sensitivity. A diagnostic algorithm was developed and evaluated through numerical simulation and experiments. Two major steps of diagnosis are the evaluation of null bias of the servovalve and the approximation of pressure sensitivity, both of which could be successfully done during normal operation of a servo system. The difference between a new servovalve and a worn valve could be clearly detected in-process, and the diagnostic test was found to be repeatable.

  • PDF