A Study on the Design and Fabrication for Partial Discharge Measurment in 22.9kV Underground Power Cable using Planar Loop Sensor (22.9kV급 지중전력케이블의 부분방전 측정을 위한 평면루프센서 설계 및 제작 연구)

  • Shin, Dong-Hoon;Lim, Kwang-Jin;Lwin, Kyawsoe;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.210-211
    • /
    • 2007
  • The objective of this paper is to effectively detect partial discharges in underground power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar loop types for underground power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Loop Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

On Diagnosis Measurement under Dynamic Loading of Ball Bearing using Numerical Thermal Analysis and Infrared Thermography (전산 열해석 및 적외선 열화상을 이용한 볼베어링의 동적 하중에 따른 진단 계측에 관한 연구)

  • Hong, Dong-Pyo;Kim, Ho-Jong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • With the modern machinery towards the direction of high-speed development, the thermal issues of mechanical transmission system and its components is increasingly important. Ball bearing is one of the main parts in rotating machinery system, and is a more easily damaged part. In this paper, bearing thermal fault detection is investigated in details Using infrared thermal imaging technology to the operation state of the ball bearing, a preliminary thermal analysis, and the use of numerical simulation technology by finite element method(FEM) under thermal conditions of the bearing temperature field analysis, initially identified through these two technical analysis, bearing a temperature distribution in the normal state and failure state. It also shows the reliability of the infrared thermal imaging technology. with valuable suggestions for the future bearing fault detection.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 2. 3-D VISUALIZATION AND MEASURMENT PROGRAM FOR MAXILLOFACIAL STRUCTURE- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -2. 악안면 구조에 대한 3차원적 시각화 및 측정프로그램 개발-)

  • Lee, Sang-Han;Mori, Yoshihide;Minami, Katsuhiro;Lee, Geun-Ho;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.321-329
    • /
    • 2001
  • To establish systematic diagnosis and treatment planning of dentofacial deformity patient including facial asymmetry or hemifacial microsomia patient, comprehensive analysis of three dimensional structure of the craniofacial skeleton is needed. Even though three dimensional CT has been developed, landmark identification of the CT is still questionable. In recent, a method for correcting cephalic malpositioning that enables accurate superimposition of the landmarks in different stages without using any additional equipment was developed. It became possible to compare the three-dimensional positional change of the maxillomandible without invasive procedure. Based on the principle of the method, a new program was developed for the purpose of diagnosis and treatment planning of dentofacial deformity patient via three dimensional visualization and structural analysis. This program enables us to perform following menu. First, visualization of three dimensional structure of the craniofacial skeleton with wire frame model which was made from the landmarks observed on both lateral and frontal cephalogram. Second, establishment of midsagittal plane of the face three dimensionally, with the concept of "the plane of the best-fit". Third, examination of the degree of deviation and direction of deformity of structure to the reference plane for the purpose of establishing surgical planning. Fourth, simulation of expected postoperative result by various image operation such as mirroring, overlapping.

  • PDF

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.