• 제목/요약/키워드: Diagnosis Device

Search Result 588, Processing Time 0.026 seconds

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

Association of Congestive Heart Failure and Death with Ankylosing Spondylitis : A Nationwide Longitudinal Cohort Study in Korea

  • Bae, Ki Hwan;Hong, Je Beom;Choi, Yoon Jin;Jung, Jin Hyung;Han, In-Bo;Choi, Jung Min;Sohn, Seil
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.2
    • /
    • pp.217-224
    • /
    • 2019
  • Objective : We attempted to discover that Ankylosing spondylitis (AS) has a comprehensive relationship with congestive heart failure and death. Methods : We used a nationwide database managed by the Korean National Health Insurance Service from 2010 to 2014. Twelve thousand nine hundred eighty-eight patients with a diagnosis of AS and 64940 age- and sex- stratified matching subjects without AS were enrolled in the AS and control groups. Incidence probabilities of 6 years congestive heart failure and death in each group were calculated. The Cox proportional hazard regression analysis was used to estimate the hazard ratio. We divided the AS and control groups into subgroups according to sex, age, income, and comorbidities. Results : During the follow-up period, 102 patients (0.79%) in the AS group and 201 patients (0.32%) in the control group developed congestive heart failure (p<0.0001). In addition, 211 (1.62%) subjects in the AS group died during the follow-up period compared to 639 (0.98%) subjects in the control group (p<0.0001). The adjusted hazard ratio of congestive heart failure and death in the AS group was 2.28 (95% confidence interval [CI], 1.80-2.89) and 1.66 (95% CI, 1.42-1.95), respectively. The hazard ratios of congestive heart failure and death were significantly increased in all of the subgroups. Conclusion : The incidence rates of congestive heart failure and death were increased in AS patients.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Factors associated with Pediatric Delirium in the Pediatric Intensive Care Unit (소아중환자실 입원 아동의 섬망 발생 관련 요인)

  • Kim, Hyo Jin;Kim, Dong Hee
    • Child Health Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.103-111
    • /
    • 2019
  • Purpose: This study aimed to investigate incidence of delirium in the pediatric intensive care unit (PICU) and to analyze associated risk factors. Methods: The participants were 95 patients, newborn to 18 years, who were admitted to the PICU. The instruments used were the Richmond Agitation Sedation Scale (RASS), and the Cornell Assessment of Pediatric Delirium. Data analysis was performed using the descriptive, $x^2$ test, t-test, and logistic regression analyses. Results: The incidence of delirium in children admitted to the PICU was 42.1%. There were significant differences according to age ($x^2=14.10$, p=.007), admission type ($x^2=7.40$, p=.007), use of physical restraints ($x^2=26.11$, p<.001), RASS score ($x^2=14.80$, p=.001), need for oxygen ($x^2=5.31$, p=.021), use of a mechanical device ($x^2=9.97$, p=.041), feeding ($x^2=7.85$, p=.005), and the presence of familiar objects ($x^2=29.21$, p<.001). Factors associated with the diagnosis of delirium were the use of physical restraint (odds ratio [OR]=13.82, 95% confidence interval [CI]=4.16~45.95, p<.001) and the presence of familiar objects (OR=0.09, 95% CI=0.03~0.30, p=.002). Conclusion: Periodic delirium assessments and intervention should be actively performed. The use of restraints should be minimized if possible. The caregiver should surround the child with familiar objects and ensure a friendly hospital environment that is appropriate for the child.

Design and Implementation of Secure UART based on Digital Signature and Encryption (디지털 서명과 암호화 기반 보안 UART의 설계와 구현)

  • Kim, Ju Hyeon;Joo, Young Jin;Hur, Ara;Cho, Min Kyoung;Ryu, Yeon Seung;Lee, Gyu Ho;Jang, Woo Hyun;Yu, Jae Gwan
    • Convergence Security Journal
    • /
    • v.21 no.2
    • /
    • pp.29-35
    • /
    • 2021
  • UART (Universal asynchronous receiver/transmitter) is a hardware device that converts data into serial format and transmits it, and is widely used for system diagnosis and debugging in most embedded systems. Hackers can access system memory or firmware by using the functions of UART, and can take over the system by acquiring administrator rights of the system. In this paper, we studied secure UART to protect against hacker attacks through UART. In the proposed scheme, only authorized users using the promised UART communication protocol are allowed to access UART and unauthorized access is not allowed. In addition, data is encrypted and transmitted to prevent protocol analysis through sniffing. The proposed UART technique was implemented in an embedded Linux system and performance evaluation was performed.

A Digital Device-Based Method for Quantifying Motor Impairment in Movement Disorders (디지털 디바이스를 이용한 이상운동증에서의 운동손상 정량화 방법)

  • Bae, Suhan;Yun, Daeun;Ha, Jaekyung;Gwon, Daeun;Kim, Young Goo;Ahn, Minkyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.247-255
    • /
    • 2020
  • Accurate diagnosis of movement disorders is important for providing right patient care at right time. In general, assessment of motor impairment relies on clinical ratings conducted by experienced clinicians. However, this may introduce subjective opinions into scoring the severity of motor impairment. Digital devices such as table PC and smart band with accelerometer can be used for more accurate and objective assessment and possibly helpful for clinicians to make right decision of patient's states. In this study, we introduce quantification algorithms of motor impairment which uses the digital data acquired during four clinical motor tests (Line drawing, Spiral drawing, Nose to finger and Hand flip tests). The step by step procedure of quantifying metrics (Tremor Frequency, Tremor Magnitude, Error Distance, Time, Velocity, Count and Period) are provided with flowchart. The effectiveness of the proposed algorithm is presented with the result from simulated data (normal, normal with tremor and slowness, poor with tremor, poor with tremor and slowness).

Rapid Detection of Clostridium tetani by Recombinase Polymerase Amplification Using an Exo Probe

  • Guo, Mingjing;Feng, Pan;Zhang, Liqun;Feng, Chunfeng;Fu, Jie;Pu, Xiaoyun;Liu, Fei
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.91-98
    • /
    • 2022
  • Tetanus is a potentially fatal public health illness resulted from the neurotoxins generated by Clostridium tetani. C. tetani is not easily culturable and culturing the relevant bacteria from infected wounds has rarely been useful in diagnosis; PCR-based assays can only be conducted at highly sophisticated laboratories. Therefore, a real-time recombinase polymerase amplification assay (Exo-RPA) was constructed to identify the fragments of the neurotoxin gene of C. tetani. Primers and the exo probe targeting the conserved region were designed, and the resulting amplicons could be detected in less than 20 min, with a detection limit of 20 copies/reaction. The RPA assay displayed good selectivity, and there were no cross-reactions with other infectious bacteria common in penetrating wounds. Tests of target-spiked serum and pus extract revealed that RPA is robust to interfering factors and has great potential for further development for biological sample analysis. This method has been confirmed to be reliable for discriminating between toxic and nontoxic C. tetani strains. The RPA assay dramatically improves the diagnostic efficacy with simplified device architecture and is a promising alternative to real-time PCR for tetanus detection.

A Development of an All-in-one Ironing System for All Style Pants (바지 형태에 구애받지 않는 융합 다림질 시스템 개발)

  • Kim, Keunsik;Kim, Jong-Hoon
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.1
    • /
    • pp.172-179
    • /
    • 2022
  • Unlike other processes such as washing, the ironing process in the laundry process is difficult to standardize and thus relies on manual labor. Unlike upper garments, pants have pleats at the waist as well as a crease line below the waist, Therefore, two separate ironing devices have been developed and used. However, in this method, problems such as additional worker input, space loss, and wrinkling of pants occur due to manual movement between processes, Consequently, a pants ironing device that combines the two equipments is required. The all-in-one pants ironing system described in this paper automatically sequentially irons the upper part and side of the pants regardless of the length, shape, and upper pleats of the pants. It also performs a self-diagnosis function while displaying the ironing progress on the user's monitor. As a result of this study, it became possible to double the amount of ironing and reduce power consumption by more than 20% compared to the case of using two independent equipment.

Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment (발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발)

  • Noh, Hyungho;Y, Hoseon
    • Plant Journal
    • /
    • v.17 no.4
    • /
    • pp.53-60
    • /
    • 2021
  • The purpose of this study was to develop a portable vibration analyzer that is effective for acquiring and analyzing vibration data of rotating equipment of a power plant and a domestic vibration monitoring system manufacturer Nada Co., Ltd. The hardware of the developed portable vibration analyzer minimizes measurement errors by calibrating the measured values obtained through measurement uncertainty for calibration of the measuring devices in the system, and is composed of a signal processing device with high resolution through high speed data processing. The software structure implements a variety of vibration plots to execute a detailed analysis program, and applies algorithms to measure and remove noise caused by disturbances while operating a rotating machine. The developed product contributed greatly to increase the user's mobility and performance, as well as to reduce the purchase cost due to localization.

Analysis of Chloride Content in Aqueous Solution and Mortar using Laser Induced Breakdown Spectroscopy (LIBS를 활용한 수용액과 모르타르 내 염화물량 분석)

  • Ryu, Hwa-Sung;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • LIBS has been attracting attention as an analytical method capable of real-time measurement without sample preparation. In this study, a Lab. scale LIBS device was fabricated to examine the applicability and reproducibility of LIBS in the analysis of chloride contents in mortar. The existing analysis method and LIBS analysis were performed simultaneously on the mortar test specimen with the chloride content adjusted. Compared to the chloride content condition of the mortar, the XRF and Potentiometric Titration results also showed a similar trend. As a result of LIBS analysis, chlorine ions were detected at a wavelength of 837.59 nm according to the chloride content condition. In order to improve the precision in various concentration ranges, the LIBS signal amplification of about 50 times through the electric field enhancement was implemented. Through the verification of the aqueous solution-based reproducibility, a high correlation between the LIBS signal strength and the Cl concentration was confirmed, and the possibility of applying LIBS to the durability diagnosis of concrete damage by chloride was confirmed.