• 제목/요약/키워드: Dewpoint

검색결과 14건 처리시간 0.03초

고온부재의 재질열화에 따른 응력부식균열 평가에 관한 연구 (A Study on Stress Corrosion Cracking Evaluation with Material Degradation of High Temperature Components)

  • 박종진;유호선;정세희
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1123-1132
    • /
    • 1996
  • It has been reported that high temperature structural components represent the phenomenon of material degradation according to a long term service under high temperature and pressure. Especially, fossile power plant components using the fossil fuel and heavy oil are affected by dewpoint corrosion of $H_2SO_4$produced during a combustion. Therefore, the service materials subjected to high temperature and pressure may occur the stress corrosion cracking. The object of this paper is to investigate SCC susceptibility according to the material degradation of the high temperature structural materials in dewpoint corrosive environment-$H_2SO_4$.The obtained results are summarized as follows : 1) In case of secondary superheater tube, the fractograph of dimple is observed at the concentration of $H_2SO_4$-5%. When the concentration of $H_2SO_4$ is above 10%, the fracture mode is shifted from a transgranular fracture to an quasi-intergranular fracture according to the increment of concentration. 2) In the relationship between [$\Delta$DBTT]$_sp$ and SCC susceptibility, it is confirmed that the greater material degradation degree is, the higher SCC susceptibility is. In addition, it can be known that SP test is useful test method to evaluate SCC susceptibility for high temperature structural components. 3) When [$\Delta$DBTT]$_sp$ is above 17$17^{\circ}C$ the SCC fracture behavior is definitely observed with SCC susceptibility of above 0.4.

Si, Mn함유 IF 고강도강의 소둔거동 및 도금특성에 미치는 이슬점 온도의 영향 (Effect of Dewpoints on Annealing Behavior and Coating Characteristics in IF High Strength Steels Containing Si and Mn)

  • 전선호;신광수;손호상;김대룡
    • 대한금속재료학회지
    • /
    • 제46권7호
    • /
    • pp.427-436
    • /
    • 2008
  • The effect of dewpoints on annealing behavior and coating characteristics such as wettability and galvannealing kinetics was studied by annealing 0.3wt%Si - 0.1~0.4wt% Mn added interstitial-free high strength steels(IF-HSS). The 0.3wt%Si-0.1wt%Mn steel exhibited good wettability with molten zinc and galvannealing kinetics after annealing when the dewpoint of $H_2-N_2$ mixed gas was above $-20^{\circ}C$. It is shown that the wettability and galvannealing kinetics are directly related to the coverage of the external(surface) oxide formed by selective oxidation during annealing. At $N_2-15%H_2$ annealing atmosphere, the increase of dewpoint results in a gradual transition from external to internal selective oxidation. The decrease of external oxidation of alloying elements with a concurrent increase of their subsurface enrichment in the substrate, showing a larger surface area that was free of oxide particles, contributed to the improved wettability and galvannealing kinetics. On the other hand, the corresponding wettability and galvannealing kinetics were deteriorated with the dewpoints below $-20^{\circ}C$. The continuous oxide layer of network and/or film type was formed on the steel surface, leading to the poor wettability and galvannealing kinetics. It causes a high contact angle between annealed surface and molten zinc and plays an interrupting role in interdiffusion of Zn and Fe during galvannealing process.

AR5 RCP 시나리오에 따른 이슬점 자료의 편의보정 및 12-시간 지속 100년 빈도 이슬점의 생성 (Bias-Correction of Dewpoint Data and Generation of Persisting 12-hour 100-year Return Period Dewpoint under AR5 RCP Scenarios)

  • 이옥정;김상단
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.234-234
    • /
    • 2016
  • 본 연구에서는 기상청 RCM으로부터 생산된 미래 이슬점자료를 이용하여 편의보정 및 시간적인 규모내림방법의 적용에 있어서 그동안 간과하고 있었던 사항들을 살펴보고, 그러한 부분들에 대한 보완방법을 100년 빈도 12-시간 지속 이슬점 산출과정을 대상으로 제안하고자 한다. 우선 기후모델로부터 도출된 자료와, 관측된 자료 사이의 일치성 여부를 먼저 확인하기 위해 기후모델로부터 도출된 자료를 이용하여 과거 관측자료와의 재현성을 평가한다. 또한 기후모델의 여러 가지 한계로 인해 생기는 불일치성을 극복하기 위해 편의보정이라는 절차를 수행하여 모델로 부터 도출된 미래 기후자료를 보정하게 된다.본 연구의 경우 5월부터 10월까지의 자료를 대상으로 매월 1-15일 시기와 16-말일로 나누어 총 12개의 시기별, 지점별(62개 지점)별로 편의보정을 수행하였다. 또한 편의보정 되어진 이슬점 자료를 바탕으로 scale-invariance 기법을 적용하여 일-단위 이슬점자료로부터 시간-단위 이슬점 정보를 추출하였다. 먼저 62개 지점별로 1981-1997년(보정기간) 17년 동안의 과거관측자료를 이용하여 시기별 일 이슬점자료로부터 시기별 12-시간 지속 100년 빈도 이슬점을 산출하는 함수관계를 구축한 후 이를 이용하여 1998-2014년(검증기간) 17년 동안의 시기별 일 이슬점 자료로부터 시기별 12-시간 지속 100년 빈도 이슬점을 산출하여, 실제 검증기간의 시간자료를 이용한 12-시간 지속 100년 빈도 이슬점과 비교해 보았다.

  • PDF

Cascade-Correlation Algorithm을 이용한 증발접시 증발량의 모형화 (Pan Evaporation Modeling using Cascade-Correlation Algorithm)

  • 김성원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.766-770
    • /
    • 2005
  • Cascade-Correlation Neural Networks Model(CCNNM) is used to estimate daily evaporation using limited climatical variables such as atmospheric temperature, dewpoint temperature, relative humidity, wind speed, sunshine duration and radiation. DeBruln equation is applied to estimate daily free-surface evaporation. It is converted into pan evaporation using pan coefficient. The results of CCNNM shows better than those of Debruin equation. This research represents that the strong nonlinear relationship such as evaporation modeling can be generalized by the CCNNM ; a special type of Backpropagation algorithm Neural Networks Model.

  • PDF

자동차 차체용 알루미늄 합금 판재의 기계적특성과 부식피로수명 (A mechanical proprties and fatigue life of aluminum alloy sheets for autobodies)

  • 박인덕;윤옥남;남기우
    • 한국해양공학회지
    • /
    • 제11권2호
    • /
    • pp.57-69
    • /
    • 1997
  • The objetive of this study is to compare the mechanical proprties of 6000 series Al-Mg-Si aluminum alloy (AC120) with 5000 series Al-Mg aluminum alloy (TG25), and to investigate the influence of corrosion solution for fatigue life. Comparing of TG25 and AC120 alloy sheets, TG25 alloy sheets showing higher plastic ratio and total elongation have better formability than AC120 alloy sheets. The hardness of nugget area was a little higher than that of base metal area. Also, grain coarsening was observed in HAZ(Heat Affected Zone). In a corrosion fatigue experiment, the fatigue life decreased as concentration increased, when a dipping time was constant. The life decreased as dippling time increased, when a concentration was constant.

  • PDF

실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구 (A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process)

  • 이홍주;김용구
    • 대한설비공학회지:설비저널
    • /
    • 제16권6호
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석 (Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

클러스터 분석을 통한 종관기단분류 및 서울에서의 일 사망률과의 관련성 연구 (Synoptic Air Mass Classification Using Cluster Analysis and Relation to Daily Mortality in Seoul, South Korea)

  • 김지영;이대근;최병철;박일수
    • 대기
    • /
    • 제17권1호
    • /
    • pp.45-53
    • /
    • 2007
  • In order to investigate the impacts of heat wave on human health, cluster analysis of meteorological elements (e.g., temperature, dewpoint, sea level pressure, visibility, cloud amount, and wind components) for identifying offensive synoptic air masses is employed. Meteorological data at Seoul during the past 30 years are used. The daily death data at Seoul are also employed. Occurrence frequency of heat waves which is defined by daily maximum temperature greater than the threshold temperature (i.e., $31.2^{\circ}C$) was analyzed. The result shows that the frequency and duration of heat waves at Seoul are increasing during the past 30 years. In addition, the increasing trend of the frequency and duration clearly appears in late spring and early autumn as well as summer. Factor analysis shows that 65.1% of the total variance can be explained by 4 components which are linearly independent. Eight clusters (or synoptic air masses) were classified and found to be optimal for representing the summertime air masses at Seoul, Korea. The results exhibit that cluster-mean values of meteorological variables of an offensive air mass (or cluster) are closely correlated with the observed and standardized deaths.

염해 오손도 예측기법 개발을 위한 오손물과 기후 인자와의 상관관계 분석 (Regression Analysis Between Climate Conditions and Contaminants for Development of Prediction Method of the Salt Pollution)

  • 김도영;김재훈;이원영;한상옥;박강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.173-175
    • /
    • 2004
  • The degree of contamination on outdoor insulators is one of the most importance factor to determine the pollution level of outdoor insulation. Outdoor insulators in coastal are affected due to salty wind blowing from the seaside. The sea salt is known as the most dangerous pollutant. As known through the preceding study, the generation of salt pollutant and the pollution degree of outdoor insulators have a close relation in accordance with meteorological conditions, such as temperature, humidity, dewpoint, wind velocity and wind direction. Therefore, at first, we have analyzed relation between meteorological conditions and contaminants for development of prediction method. In this paper, we have investigated a statistical estimation technique based on actual data for equivalent salt deposit density(ESDD) of outdoor insulators which were installed in Kochang field test substation with multiple linear regression analysis.

  • PDF

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF