• Title/Summary/Keyword: Dewatering Sludge

Search Result 97, Processing Time 0.021 seconds

Performance Evaluation of Electrocoagulation and Electrodewatering for the Reduction of Water Content in Wastewater Sludge (전기응집 및 탈수 시스템을 이용한 슬러지 함수율 저감 특성)

  • 이재근;김영환;신희수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1098-1107
    • /
    • 2001
  • This study is to develop the pretreatment for the excess and digested sludge by elector-coagulation and dewatering. Electrocoagulation is applied to excess and digested sludge before transferring to the pistion type for dewatering. Piston type filter press as a laboratory scale plant was used to estimate the dewaterability. MMD of excess sludge was increased from initial diameter of particles ($34.16{\mu}m$) to the 87%($64.01{\mu}m$) after electrocoagulation. Al electrode is more effective than Fe electrode for the dewaterabiltity of excess sludge Electrodewatering after electrocoagulation as pretreatment makes the water content of sludge cake 50~60 wt%.

  • PDF

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

A Deduction of Optimum Conditions as Mixing Ratio of CWOS and Loess for Sewage Sludge Conditioning (하수슬러지 개량을 위한 CWOS와 황토의 혼합비율에 따른 최적조건의 도출)

  • Jung, Yoo-Jin;Ju, Yuen-Gyung;Sung, Nak-Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.2
    • /
    • pp.125-131
    • /
    • 2002
  • This study was carried out to evaluated for dewaterability of sewage sludge using waste oystershell and loess. The Jar-Test and the Buchner funnel test were proceeded for the assessment of dewaterability of a thickened sludge and digested sludge. TTF(Time to Filter), SRF(Specific Resistance to Filtration) were adopted as the valuation indices of sludge dewaterability. Dewatering conditioner which composed of both oystershell and loess is much dewaterable than the one composed of only oystershell. In the course of combining with oystershell and loess, the following fact was found that the dewaterability of the combination which have the higher ratio of oystershell than that of loess is superior. The most suitable oystershell :loess ratio of dewatering conditioner is 9:1 in treating both thickened sludge and digested sludge.

  • PDF

A Study on the Advanced Treatment Process Improvement through the Dewatering Application an Expressway Rest Area Individual Sewage Treatment Plant (휴게소 개인하수처리시설의 슬러지 탈수공정 적용에 통한 고도처리 개선 연구)

  • Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.63-69
    • /
    • 2017
  • Small size privately owned wastewater treatment plants have been difficult to treat their wasted sludge and maintain steady effluent quality compared with publicly owned wastewater treatment plants. Therefore, this study has focused on treatment efficiency enhancement, specially nitrogen removal efficiency by recycling dewatering filtrate as an alkalinity additive from filter press using $CaCO_3$. As the result, it was found that the optimal mixing ratio between the excess sludge and $CaCO_3$ was 1:2. The major operation parameters such as specific substrate utilization rate, specific nitrification rate, and specific denitrification rate were also improved 64% ($0.048-0.079mg\;BOD_5/mg\;MLVSS{\cdot}day$), 35% ($0.020-0.027mg\;NH_3-N/mg\;MLVSS{\cdot}day$) and 68% ($0.051-0.086mg\;NO_3{^-}-N/mg\;MLVSS{\cdot}day$), respectively, after the adoption of new methods. Therefore, both the problem of sludge treatment at small scale plants and the need for efficiency improvement could be solved.

The Characteristics of Municipal wastewater Sludge Dewatering Using Oyster Shell Powder (굴껍질을 이용한 하수슬러지의 탈수특성에 관한 기초연구)

  • 신남철;문종익;정유진;장혜정;성낙창
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.30-33
    • /
    • 2000
  • The objective of this study is to examine the subsitiution effect of the waste oyster shell powder as the conditioning agent in municipal wasterwater sludge dewatering process. Beacuse the oyster shells have a large amount(about 38% by weight) of alkaline minerals, such as calcium and magnesium, they are thought to have the potential as a good conditioning agent. In this study, the physico-chemical properties of powdered oyster shells (75${\mu}{\textrm}{m}$ or 200 mesh) and the dewatering characteristics of municipal waste water sludge using powdered oyster shells and CaCO3 are investigated. The conclusions are as follows, 1. Oyster shell could produce calcium ions up to 14ppm at pH-7.0, and this represents that oyster shell is a potential properties as a good conditioner. 2. 100ml of wastewater sludges, conditioned with pretreated oyster shell, are dewatered to the level of 25% solid concentration. 3. Wasterwater sludges, conditioned with oyster shell and CaCO3 are dewatered to the level of 32% solid concentration. And this shows that two-stage combined conditioning process is desirable than the one-stage conditioning process.

  • PDF

Sludge Minimization by Using Dewater and Thermal Treatment in the Water Treatment Plant (탈수(脫水) 및 건조기법(乾燥技法)을 이용한 정수장(淨水場) 슬러지 감량화(減量化))

  • Jun, Hang-Bae;Kim, Yong-Han;Kim, Ryang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.87-98
    • /
    • 1994
  • Sludge minimization in an water treatment plant can be achieved by optimizing a main water treatment process as well as by enhancing a thickening and a dewatering facilities. In this study, dewatering and drying techniques for reducing the quantity of the water sludge generated from the conventional water treatment plant in the local states were investigated by reducing its water content. Not only the types and dosages of polymers but also the mixing intensity of the mixtures of a concentrated sludge and polymers on the different pH were evaluated for the optimum dewatering conditions of the water sludge. Weight reduction of the water sludge was also tested at a given temperature range. The dewatering efficiency of the water sludge was not affected by the types of polymer but by mixing intensity(GT value) in this study. pH effect on dewaterbility of the water sludge took a major role at the neutral pH range. The optimal polymer dose was 1.5 mg-polymer/g-TSS(about 40mg/L as polymer). Dewaterability was enhanced at a lower mixing intensity(GTbelow 10,000 sec-1). Free water in the void of sludge cake was dried around $100^{\circ}C$, chemical bound water was evaporated around $320^{\circ}C$, and organic material was burned out at the range of 300 to $600^{\circ}C$. Ignition losses of the water sludge were varied 15 to 40 % as the raw water quality. The ignition loss due to the chemical bound water was 10-20% and the loss due to the organic material was 4-20% of the total ignition loss.

  • PDF

Effect of Microwave Irradiation and Chemical Conditioning for Dewatering Characteristics of Sludge (슬러지의 탈수 특성에 대한 마이크로파와 약품개량의 영향)

  • Park, Sang-Sook;Kang, Hwa-Young;Wang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.732-738
    • /
    • 2005
  • The purpose of this study is the presentation of the proper microwave treatment conditions by means of the investigation of the effect of microwave irradiation on the dewaterability and dryability of sludge. For the improving of dewatering efficiency of sludge using the microwave, the proper time of microwave irradiation is very important. The dewatering efficiency of thickening sludge conditioned by microwave irradiation for proper time was considerably improved with reducing of capillary suction time from 52.3 sec to 30.8 sec, and the sludge conditioned by microwave irradiation had contained the moisture of 81.4% after that pressure filtrationed. The result of drying characteristics of dewatered sludge using the microwave irradiation and furnace heating, for drying of sludge to moisture of below 55%, microwave irradiation time was required 3 min, whereas, furnace heating was required 40 min at $105^{\circ}C$, 20 min at $170^{\circ}C$ and 9 min at $300^{\circ}C$, respectively. We certified that the drying of dewatered sludge using the microwave irradiation was effectively reduction of moisture of sludge compare to traditional heating method.

A Study on Characteristics of Water Content Changes of Wastewater Sludge Using Direct Current Electricity (직류전기를 이용한 하수슬러지 함수율 변화특성에 관한 연구)

  • Ahn, Jeong-Mo;Song, Ji-Yun;Joo, Jae-Young;Bae, Yun-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2010
  • This study examined the change of water content in sludge using direct current electric equipment for decreasing the amount of sludge. The experiment showed that the average density of solids in the sludge treated by direct current before the centrifugal dewatering process was increased by 47.8%, when compared to those not treated by direct current. From the result of measuring the granularity of the sludge by the direct current treatment, that the average particle size of the sludge that was not exposed to the electric current was 52.36 ${\mu}m$, and more than 90% of the sludge was <94.29 ${\mu}m$ in size. On the other hand, the average particle size of the sludge passed through the direct current was 28.67 ${\mu}m$, and more than 90% of the sludge was 52.46 ${\mu}m$. This means that the average particle size of the sludge treated by the direct current was 45.2% smaller, and the standard deviation of granularity was improved. Because of water that separated from sludge moves to the (+) pole, larger particles become smaller and fine particles combine together, resulting in the equalization of the particle size. On the sludge after the centrifugal dehydrator, the change of the water content by the direct current was measured. The results showed that the average density of the solids was increased by 44.2% compared.

A study for Beating Filter Press Dewatering Technology (열(熱) 필터프레스 기술(技術)을 통한 슬러지 탈수율(脫水率) 향상(向上)을 위한 연구(硏究))

  • Lee, Jung-Eun;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.38-45
    • /
    • 2006
  • The thermal filter press dewatering(TFPD) technology to improve the dewaterability through increasing the inner vapor pressure, lowering the filtration viscosity and forming the porosity easily within cake as applying the heat at the sludge layer was developed in this study. The hot water with temperature of $95^{\circ}C$ and pressure of $1.2kg_f/cm^2$ was supplied to the heating plate equipped between filter plates with plate size of $470{\times}470mm$ and material of polypropylene. Sludge was dewaterd by supplying pressure of $5kg_f/cm^2$ and then by squeezing pressure of $15kg_f/cm^2$. As a results of estimating the characteristics of thermal dewatering to consider the initial water content and organic content to be influenced by a period of water shortage and rainwater, the dewatered cake water content was about 35 wt% and dewatering velocity was $4DSkg/m^2{\cdot}hr$ under the rainwater period, and the dewatered cake water content was about 50 wt% and dewatering velocity was $1.5DSkg/m^2{\cdot}hr$ in the case of sludge of water shortage season. These results was superior to the mechanical dewatering performance with water content of 70wt% and dewatering velocity of $0.9DSkg/m^2{\cdot}hr$. On the base of the results of TFPD, energy consumpted to deal with DS(Dry Solid) of 1kg was estimated by 300 kJ. It was analyzed that the energy consumption of TFPD was decreased about one third with comparison to the dryer system. Dewatering velocity of this technology was faster than the one of mechanical dewatering equipment and it was easier to product low water content cake. Therefore, this technology was recognized that dewaterability was predominant because of the fast of dewatering velocity and production of low water content cake, and also this known as economical efficiency was excellent because of low energy consumption in comparison with dryer.