• Title/Summary/Keyword: Dew

Search Result 314, Processing Time 0.03 seconds

Analysis of Meteorological Features and Prediction Probability Associated with the Fog Occurrence at Chuncheon (춘천의 안개발생과 관련된 기상특성분석 및 수치모의)

  • Lee Hwa Woon;Lee Kwi Ok;Baek Seung-Joo;Kim Dong Hyeok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.303-313
    • /
    • 2005
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years $(2000\~2003)$ data at Chuncheon and the probability of prediction is investigated. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for $2\~4$ hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1m/s. Especially, about $42\%$ of foggy day fell on the calm $(0\~0.2\;ms^{-1})$ conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water surface temperature was calculated by using Water Quality River Reservoir System (WQRRS) and then it was used as the surface boundary condition of MM5. The numerical experiment was carried out for 2 days from 1300 LST on 14 October 2003 to 1300 LST on 16 October 2003 and fog was simulated at dawn on 15 and 16 October 2003. Simulated air temperature and dew point temperature indicate the similar tendency to observation and the simulated difference between air temperature and dew point temperature has also the similar tendency within $2^{\circ}C$. Thus, the occurrence of fog is well simulated in the terms of the difference between air temperature and dew point temperature. Horizontal distribution of the difference between air temperature and dew point temperature from the numerical experiment indicates occurrence, dissipation and lasting time of fog at Chuncheon. In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

Changes in Absorption Coefficient of Krypton Hygrometer in Long-term Monitoring of Evapotranspiration and Its Calibration Using a Dew Point Generator (증발산 장기 관측에 따른 크립톤 습도계의 흡수 계수의 변화와 이슬점 생성기를 이용한 기기 보정)

  • Park Yunho;Kim Joon;Lee Heechoon;Lim Jonghwan;Kwon Wontae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.75-79
    • /
    • 2000
  • Calibrations of fast-response krypton hygrometers were carried out using a dew-point hygrometer to investigate the changes in their absorption coefficients due to long-term field operation. Absorption coefficients changed proportionally with the number of hours of field operation. The increase in absorption coefficient indicates that the water vapor flux, calculated with the original absorption coefficient, would underestimate the true flux in the field. To minimize the uncertainty in quantifying evapotranspiration and surface energy budget studies, frequent calibrations (for example, every 1500 hours of field operation) of krypton hygrometer are recommended.

  • PDF

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

The Sintering Behaviour of Fe-Mn-C Powder System, Correlation between Thermodynamics and Sintering Process, Mn Distribution, Microstructure

  • Hryha, Eduard;Dudrova, Eva
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.839-840
    • /
    • 2006
  • Sintering behavior of the Fe-0.8Mn-0.5C powder system was studied on the specimens with a density of ${\sim}7.0g/cc$ sintered at $1120^{\circ}C$ for 30 min in a gas mixture of $7%H_2/93%N_2$ with the inlet dew point of $-60^{\circ}C$. During the atmosphere monitoring ($CO/CO_2$-content and dew point) was showed, that carbothermical reduction occurs in two different temperature ranges; three peaks of dew point profile also can be distinguished during sintering cycle as well. Following sintering the Mn-content distribution and microstructures around the Mn-source were micro-analytical evaluated; the results showed that manganese travels through porous iron matrix up to ${\sim}60{\mu}m$.

  • PDF

Water Vapor Supply Study for Air and Carbon dioxide (공기와 이산화탄소 가스에 수분공급을 위한 연구)

  • Lee, Taeck Hong;Park, Tae Seong;Kim, Tae Wan;Noh, Jae Hyun;Kang, Young Jin;Lee, Seung Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.72-78
    • /
    • 2014
  • The study has been designed to develop water vapor supply for semiconductor industry, industrial gas manufacturing, impurities analysis, and fuel cell. Water concentration in air reached $1019{\mu}mol/mol$ at dew temp ($-20^{\circ}C$) and water concentration in CO2 reached $127{\mu}mol/mol$ at dew temp ($-40^{\circ}C$. Carbon dioxide needs more wet gas than air because interaction potential of carbon dioxide shows more strong attraction than air.

A Study on the Design Parameters of a Gasket and Innercase of a Refrigerator to Reduce Dew Generation on the Outer Surface (표면의 이슬 맺힘 저감을 위한 냉장고 가스켓 및 냉동냉장실 내벽 구조개선에 관한 연구)

  • Kang, Seok-Hoon;Kim, Seong-Jin;Kim, Ju-Hwan;Min, June-Kee;Sohn, Chang-Min;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.457-463
    • /
    • 2012
  • Current refrigerators are designed to have thin doors and walls to facilitate user convenience and increase inner storage space. However, the thin doors and walls gives rise to the problem of dew generation on the outer surface of a refrigerator due to a large critical temperature difference between the outer wall and the room air; So far, an electric heater is commonly used for making the dew to evaporate; in this case, the heater inevitably requires additional electrical power. We propose a new approach to reduce the dew generation in a refrigerator by redesigning the gasket and varying the thickness of the inner case of the refrigerator. The results of simulations performed in this study indicate that the surface temperature in the region where dew was generated was increased by approximately $0.39{\sim}3.07^{\circ}C$ without the use of a heater.

Earth Science Prospective Teachers' Perceptions on the Relationship between Absolute Humidity and Dew Point Temperature (절대 습도와 이슬점 온도의 관계에 대한 지구과학 예비 교사들의 인식)

  • Kang, So Ra;Seo, Eun-Kyoung;Kim, Dong Young
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.624-638
    • /
    • 2019
  • A questionnaire was administered, and all responses were analyzed to examine prospective teachers' conceptual understanding of the relationship between dew point temperature and absolute humidity in air parcels. The responses revealed that many prospective teachers have substantial misconceptions about the relationship. For example, some thought that the absolute humidity and the dew point temperature are proportional to each other, and that the dew point temperature is proportional to the water vapor mass in the parcel. The misconceptions seemingly stemmed from inadequate descriptions on the relationship in middle-school science textbooks of the 7th and 2007 revised curricula. The study notes that the first year students' textbook of the 2015 revised curriculum introduced the concepts of evaporation, condensation, and volume changes as a function of gaseous pressure and temperature, from a perspective of molecular motion. It is suggested that keeping this perspective in the middle school curriculum, while introducing water vapor pressure as the measure of water vapor amount and dew point temperature, should help prevent middle school teachers and students from having misconceptions. There should be a concerted effort to make the science curriculum more consistent and coherent across the grade levels.

A Study of Horizontal Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials of Solid Insulator in Quasi-Uniform Field (Dry Air 중의 준평등전계에서 노점과 고체절연물 재질에 따른 수평연면방전 특성 연구)

  • Kang, Byoung-Chil;Seok, Jeong-Hoo;Min, Gyeong-Jun;Bae, Sungwoo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2015
  • This study investigates the Horizontal surface discharge characteristics of solid insulators by varying their materials, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polyethlene and polyurethane. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polyethlene is higher than that of polyurethane. Moreover, it is observed that the flashover voltage increases as the horizontal distance between the electrodes of each solid insulator become larger, respectively. However, as the pressure is increased, flashover voltage of the solid insulators is saturated. Therefore, selection of cost-effective insulation is needed in order to appropriate pressure.

A Study on Factors that Influence Traffic Accident Severity in Road Surface Freezing (결빙구간의 교통사고 심각도 영향 요인 연구)

  • Lee, Sang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.150-156
    • /
    • 2017
  • A frozen road surface increases traffic accidents during the winter season. Hence, information on easily-frozen road sections and their specificities are required to prevent traffic accidents. Frozen road surfaces are determined by equipment measuring road surface temperatures. However, there are limitations in investigating the entire road network. Therefore, it is imperative to develop new methods that effectively determine road surface freezing risks. Meteorologically, road surfaces are frozen when the actual temperature cools down to the dew point temperature. Under this condition, there is likely to be frost if relative humidity reaches 100% and frozen road surfaces as the temperature gets lower. Meteorological characteristics give us an alternative to a direct measurement road surface temperature to estimate risks of road surface freezing. Based on the clues, the relationship between severity of traffic accidents and temperature changes is empirically investigated using Paju weather data. The results reveal that as the temperature gets lower and changes in current temperature are relatively small, the severity of traffic accidents become higher. In addition, the same is true when the difference between current temperature and the dew point temperature is relatively small, as it increases possibilities of road surface freezing. Future studies must investigate how current temperature and the dew point temperature affect road surface freezing and thereby establish a time-space scope to estimate possible road surface freezing sections using only weather and road material type data. This would provide invaluable information for predicting and preventing frozen road accidents based on weather patterns.

A Study on the Effect of Hot Lines and the Assembly of Flange for a Refrigerator to Reduce Dew Generation (냉장고 Flange부 이슬 맺힘 방지를 위한 열선의 영향 및 조립에 관한 연구)

  • Kim, Na Hyun;Cho, Jong Rae;Park, Sang Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • When the temperature of a flange in a refrigerator is reduced to the dew point, condensation is generated on the flange. Generally, hot lines, having a temperature of $35^{\circ}C$, are located near the flange to increase its surface temperature above the dew point. Hot lines are installed in close contact with the flange in order to increase the heat transfer from the hot lines to the flange surface. Through this work, the effects of the hot line shape and installation conditions, including a gap between the hot line and flange, and the function of a spacer in the inner case of the refrigerator were investigated. Additionally, an optimal shape of the inner case for easy assembling is proposed considering the contact between the hot line and flange.