• Title/Summary/Keyword: Device-to-device

Search Result 25,588, Processing Time 0.058 seconds

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

A Comparison of Bioacoustic Recording and Field Survey as Bird Survey Methods - In Dongbaek-dongsan and 1100-altitude Wetland of Jeju Island - (조류 조사 방법으로써 생물음향 녹음과 현장 조사의 비교 - 제주 동백동산과 1100고지 습지를 대상으로 -)

  • Se-Jun Choi;Kyong-Seok Ki
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.5
    • /
    • pp.327-336
    • /
    • 2023
  • This study aimed to propose an effective method for surveying wild birds by comparing the results of bioacoustic detection with those obtained through a field survey. The study sites were located at Dongbaek-dongsan and a 1100-altitude wetland in Jeju-do, South Korea. The bioacoustic detection was conducted over the course of 12 months in 2020. For the bioacoustic detection, a Song-meter SM4 device was installed at each study site, recording bird songs in 1-min per hour, .wav, and 44,100 Hz format. The findings of the field survey were taken from the 「Long-term trends of Bird Community at Dongbaekdongsan and 1100-Highland Wetland of Jeju Island, South Korea.」 by Banjade et al. (2019). The results of this study are as follows. First, the avifauna identified using bioacoustic detection comprised 29 families and 46 species in Dongbaek-dongsan, and 16 families and 25 species in the 1100-altitude wetland. Second, based on the song frequency, the dominant species in Dongbaek-dongsan were Hypsipetes amaurotis (Brown-eared Bulbul, 33.62%), Horornis diphone (Japanese Bush Warbler, 12.13%), and Zosterops japonicus (Warbling White-eye, 9.77%). In the 1100-altitude wetland the dominant species were Corvus macrorhynchos (Large-billed Crow, 27.34%), H. diphone (19.43%), and H. amaurotis (16.56%). Third, in the field survey conducted at Dongbaek-dongsan, the number of detected bird species was 39 in 2009, 51 in 2012, 35 in 2015, and 45 in 2018, while the bioacoustic detection identified 46 species. In the field survey conducted in the 1100-altitude wetland, the number of detected bird species was 37 in 2009, 42 in 2012, 34 in 2015, and 38 in 2018, while the bioacoustics detection identified 25 species. Overall, 43.6% of the 78 species detected in the field survey in Dongbaek-dongsan (34 species) were identified using bioacoustic detection, and 38.3% of the 47 species detected in the field survey in the 1100-altitude wetland (18 species) were identified using bioacoustic detection. Fourth, the bioacoustic detection identified 9 families and 12 species of birds in Dongbaek-dongsan, and 3 families and 7 species of birds in the 1100-altitude wetland. No results from field survey were available for these species. The identified birds were predominantly nocturnal, including Otus sunia (Oriental Scops Owl) and Ninox japonica (Northern Boobook), passage migrants, including Larvivora cyane (Siberian Blue Robin), L. sibilans (Rufous-tailed Robin), and winter visitors with a relatively small number of visiting individuals, such as Bombycilla garrulus (Bohemian Waxwing) and Loxia curvirostra (Red Crossbill). Fifth, the birds detected in the field survey but not through bioacoustic detection included 18 families and 48 species in Dongbaek-dongsan and 14 families and 27 species in the 1100-altitude wetland; the most representative families were Ardeidae, Accipitridae, and Muscicapidae. This study is significant as it provides essential data supporting the possibility of an effective survey combining bioacoustic detection with field studies, given the increasing use of bioacoustic devices in ornithological studies in South Korea.

The Aspects and Meaning of "Wind" Accepted in Sijo (고시조(古時調)에 수용된 '바람'의 양상과 역할)

  • Byun Seung-goo
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.49
    • /
    • pp.401-432
    • /
    • 2024
  • This article examines the types of "wind (바람)" accepted in sijo (three-verse poems), focusing on the accepted pattern, and investigating its role and meaning. The summary is as follows: first of all, the works of "wind" were accepted in the sijo, and the total number of works was 620. There were 459 short sijo, and 161 long sijo. On the other hand, 148 authors wrote on "The Wind," and in the Late Joseon Dynasty, 90 authors composed 265 poems, the most. In the Early Joseon Dynasty, 50 poets composed 111 poems. Most of them were civil officials, and 170 poems were identified. Next, the aspect of jang (章) was confirmed to occur 684 times in total, with 632 instances of being single uses and 52 instances of duplication. Meanwhile, the core of the sijo, the first sentence of the last chapter, contains 'wind (바람)' 34 times in 25 words. And in terms of the aspect of the particle combined with 'wind,' the nominative particle appeared the most at 113 instances, and the auxiliary particle 'eun/neun (은/는)' was the most numerous at 58 instances. As for the types of wind contained in sijo, there are 6 major categories: 106 medium categories, with the total frequency is 688. 'Singular' appears 133 times in 6 words, and 'combination' appears 121 times in terms of total frequency. The combination with terrestrial objects was the most frequent at 79 times, and the combination with 'heavenly' objects was 75 times with 3 words, and 'mixture' indicated a mixture of several objects, with 7 words occurring 42 times. Second the literary acceptance and role of 'wind' in Sijo was examined. First, 'acceptance' and the role as a medium for conveying ideas, acceptance and the role as the development of ideas, and acceptance and role of literary expression. Through this, it can be seen that 'wind' in Sijo was accepted in literature and played a major role. Lastly, the role and meaning of wind in Sijo can be seen in the fact that it remains differentiated from other form of ancient literature or other genres. It serves as a literary device that effectively expresses the theme, and the scope of the material accepted in Sijo was expanded through wind.

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

A Review of Personal Radiation Dose per Radiological Technologists Working at General Hospitals (전국 종합병원 방사선사의 개인피폭선량에 대한 고찰)

  • Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • To find the personal radiation dose of radiological technologists, a survey was conducted to 623 radiological technologists who had been working at 44 general hospitals in Korea's 16 cities and provinces from 1998 to 2002. A total of 2,624 cases about personal radiological dose that were collected were analyzed by region, year and hospital, the results of which look as follows : 1. The average radiation dose per capita by region and year for the 5 years was 1.61 mSv. By region, Daegu showed the highest amount 4.74 mSv, followed by Gangwon 4.65 mSv and Gyeonggi 2.15 mSv. The lowest amount was recorded in Chungbuk 0.91 mSv, Jeju 0.94 mSv and Busan 0.97 mSv in order. By year, 2000 appeared to be the year showing the highest amount of radiation dose 1.80 mSv, followed by 2002 1.77 mSv, 1999 1.55 mSv, 2001 1.50 mSv and 1998 1.36 mSv. 2. In 1998, Gangwon featured the highest amount of radiological dose per capita 3.28 mSv, followed by Gwangju 2.51 mSv and Daejeon 2.25 mSv, while Jeju 0.86mSv and Chungbuk 0.85 mSv belonged to the area where the radiation dose remained less than 1.0 mSv In 1999, Gangwon also topped the list with 5.67 mSv, followed by Daegu with 4.35 mSv and Gyeonggi with 2.48 mSv. In the same year, the radiation dose was kept below 1.0 mSv. in Ulsan 0.98 mSv, Gyeongbuk 0.95 mSv and Jeju 0.91 mSv. 3. In 2000, Gangwon was again at the top of the list with 5.73 mSv. Ulsan turned out to have less than 1.0 mSv of radiation dose in the years 1998 and 1999 consecutively, whereas the amount increased relatively high to 5.20 mSv. Chungbuk remained below the level of 1.0 mSv with 0.79 mSv. 4. In 2001, Daegu recorded the highest amount of radiation dose among those ever analyzed for 5 years with 9.05 mSv, followed by Gangwon with 4.01 mSv. The area with less than 1.0 mSv included Gyeongbuk 0.99 mSv and Jeonbuk 0.92 mSv. In 2002, Gangwon also led the list with 4.65 mSv while Incheon 0.88 mSv, Jeonbuk 0.96 mSv and Jeju 0.68 mSv belonged to the regions with less than 1.0 mSv of radiation dose. 5. By hospital, KMH in Daegu showed the record high amount of average radiation dose during the period of 5 years 6.82 mSv, followed by GAH 5.88 mSv in Gangwon and CAH 3.66 mSv in Seoul. YSH in Jeonnam 0.36 mSv comes first in the order of the hospitals with least amount of radiation dose, followed by GNH in Gyeongnam 0.39 mSv and DKH in Chungnam 0.51 mSv. There is a limit to the present study in that a focus is laid on the radiological technologists who are working at the 3rd referral hospitals which are regarded to be stable in terms of working conditions while radiological technologists who are working at small-sized hospitals are excluded from the survey. Besides, there are also cases in which hospitals with less than 5 years since establishment are included in the survey and the radiological technologists who have worked for less than 5 years at a hospital are also put to survey. We can't exclude the possibility, either, of assumption that the difference of personal average radiological dose by region, hospital and year might be ascribed to the different working conditions and facilities by medical institutions. It seems therefore desirable to develop standardized instruments to measure working environment objectively and to invent device to compare and analyze them by region and hospital more accurately in the future.

  • PDF

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

The Jurisdictional Precedent Analysis of Medical Dispute in Dental Field (치과임상영역에서 발생된 의료분쟁의 판례분석)

  • Kwon, Byung-Ki;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.283-296
    • /
    • 2006
  • Along with the development of scientific technologies, health care has been growing remarkably, and as the social life quality improves with increasing interest in health, the demand for medical service is rapidly increasing. However, medical accident and medical dispute also are rapidly increasing due to various factors such as, increasing sense of people's right, lack of understanding in the nature of medical practice, over expectation on medical technique, commercialize medical supply system, moral degeneracy and unawareness of medical jurisprudence by doctors, widespread trend of mutual distrust, and lack of systematized device for solution of medical dispute. This study analysed 30 cases of civil suit in the year between 1994 to 2004, which were selected among the medical dispute cases in dental field with the judgement collected from organizations related to dentistry and department of oral medicine, Yonsei university dental hospital. The following results were drawn from the analyses: 1. The distribution of year showed rapid increase of medical dispute after the year 2000. 2. In the types of medical dispute, suit associated with tooth extraction took 36.7% of all. 3. As for the cause of medical dispute, uncomfortable feeling and dissatisfaction with the treatment showed 36.7%, death and permanent damage showed 16.7% each. 4. Winning the suit, compulsory mediation and recommendation for settlement took 60.0% of judgement result for the plaintiff. 5. For the type of medical organization in relation to medical dispute, 60.0% was found to be the private dental clinics, and 30.0% was university dental hospitals. 6. For the level of trial, dispute that progressed above 2 or 3 trials was of 30.0%. 7. For the amount of claim for damage, the claim amounting between 50 million to 100 million won was of 36.7%, and that of more than 100 million won was 13.3%, and in case of the judgement amount, the amount ranging from 10 million to 30 million won was of 40.0%, and that of more than 100 million won was of 6.7%. 8. For the number of dentist involved in the suit, 26.7% was of 2 or more dentists. 9. For the amount of time spent until the judgement, 46.7% took 11 to 20 months, and 36.7% took 21 to 30 months. 10. For medical malpractice, 46.7% was judged to be guilty, and 70% of the cases had undergone medical judgement or verification of the case by specialists during the process of the suit. 11. In the lost cases of doctors(18 cases), 72.2% was due to violence of carefulness in practice and 16.7% was due to missing of explanation to patient. Medical disputes occurring in the field of dentistry are usually of relatively less risky cases. Hence, the importance of explanation to patient is emphasized, and since the levels of patient satisfaction are subjective, improvement of the relationship between the patient and the dentist and recovery of autonomy within the group dentist are essential in addition to the reduction of technical malpractice. Moreover, management measure against the medical dispute should be set up through complement of the current doctors and hospitals medical malpractice insurance which is being conducted irrationally, and establishment of system in which education as well as consultation for medical disputes lead by the group of dental clinicians and academic scholars are accessible.