• Title/Summary/Keyword: Device-to-Device

Search Result 25,316, Processing Time 0.052 seconds

CdSe Quantum Dot based Transparent Light-emitting Device using Silver Nanowire/Ga-doped ZnO Composite Electrode (AgNWs/Ga-doped ZnO 복합전극 적용 CdSe양자점 기반 투명발광소자)

  • Park, Jehong;Kim, Hyojun;Kang, Hyeonwoo;Kim, Jongsu;Jeong, Yongseok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.6-10
    • /
    • 2020
  • The silver nanowires (AgNWs) were synthesized by the conventional polyol process, which revealed 25 ㎛ and 30 nm of average length and diameter, respectively. The synthesized AgNWs were applied to the CdSe/CdZnS quantum dot (QD) based transparent light-emitting device (LED). The device using a randomly networked AgNWs electrode had some problems such as the high threshold voltage (for operating the device) due to the random pores from the networked AgNWs. As a method of improvement, a composite electrode was formed by overlaying the ZnO:Ga on the AgNWs network. The device used the composite electrode revealed a low threshold voltage (4.4 Vth) and high current density compared to the AgNWs only electrode device. The brightness and current density of the device using composite electrode were 55.57 cd/㎡ and 41.54 mA/㎠ at the operating voltage of 12.8 V, respectively, while the brightness and current density of the device using (single) AgNWs only were 1.71 cd/㎡ and 2.05 mA/㎠ at the same operating voltage. The transmittance of the device revealed 65 % in a range of visible light. Besides the reliability of the devices was confirmed that the device using the composite electrode revealed 2 times longer lifetime than that of the AgNWs only electrode device.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Smart Home Healthcare Device based on Ubiquitous Communication

  • Kim, Keun-Young;Cha, Joo-Hun;Park, Mig-Non
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2235-2239
    • /
    • 2003
  • The aim of this research is to study and develop enabling technologies for home healthcare device with ubiquitous network. The motivation of this paper is to enable healthcare in home, to development the device for smart home health care. To achieve the aim, we must develop the prototype platform based on home gateways, distributed context user interface based on UPnP and support for information sharing with high speed power line communication and mobile infra-structures. And IPv6 is the base technology of this platform. In this paper, we concern that physical health, mental health and medical emergencies is all of home healthcare. With the smart device, we evaluate the connectivity, automatic information extraction and private data exchange and event driven message. The result of this paper is demonstration of smart device for ubiquitous communication in a healthcare application such as patient monitoring device and several information services. In conclusion, home healthcare will support more healthy and easy living for a human.

  • PDF

The Effect of a Portable Voice Feedback Device on the Hyperfunctional Voice Behaviors of Children with Vocal Nodules (휴대용 음성 피드백 도구의 사용이 과기능적 음성 행동의 발생 빈도에 미치는 영향)

  • Lee, Moo-Kyung
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.31-36
    • /
    • 2009
  • This study attempted to examine the effects of a portable voice feedback device on the hyperfunctional voice behaviors of children with vocal nodules when they wore the device in their daily lives. The device could set fundamental frequency and intensity at optimal levels for the subjects, It produces an audible alarm for inappropriate hyperfunctional voices beyond the preset levels, In addition, the frequency of hyperfunctional voice behaviors was recorded by the device, therefore the users were able to chart their number of hyperfunctional voice behaviors per day, According to results acquired after having subjects wear the device for 12 weeks, the subjects' frequency of hyperfunctional voice behaviors decreased significantly (p < .01). Especially from the first to fourth week, the frequency of their hyperfunctional voice behaviors declined significantly.

  • PDF

Design of Roller-Type Metering Device for Precision Planting (정밀 파종용 롤러식 배종장치의 설계)

  • 류일훈;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.401-410
    • /
    • 1997
  • Scattering of seeds is one of the problems in the hill- dropping planters with a roller-type metering device. For crops like rice, corns and beans, the hill-dropping is own better for a high yield than the drill planting. The roller type metering device has been used for the drill planters and has many advantages. However, it has a problem of scattering of seeds when they are placed on rows. In this study a method was developed to design the roller type metering device fir the precision hill-droppings. Design parameters were derived to configure completely the geometries of the roller and brush. The method was applied to the design of the metering device of the rice seeding machines. The field test showed that the metering device designed by the method made a better performance of seed placement than that made by the precvious one. The method also can be applied to the design of metering devices for the precise hill-droppings of other crops.

  • PDF

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

Effects of Irrigation/Aspiration Device and Viscoelastic Material on Complication after Extracapsular Lens Extraction in Dogs (개에서 Irrigation/Aspiration장비와 점탄물질이 수정체 낭외적출술후의 합병증에 미치는 효과)

  • 우흥명;권오경;남치주
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.56-64
    • /
    • 1997
  • These studies were performed to investigate the complications affecting the vision after extracapsular lens extraction(ECE), the effects of an I/A (irrigation & aspiration)device and a viscoelastic material used on the vision, the occurrence of complications and the effective corneal incision method to reduce the corneal opacity in dogs. ECE was performed bilaterally with 3 different methods using clinically normal twele mixed dogs; the method in which I/A device and viscoelastic material were not used, the method in which I/A device was used but viscoelastic material not, and the method in which I/A device and viscoelastic material were used. Postoperative complications were observed as followed; conjunctival injection, uveitis, corneal opacity due to endothelial cell loss, hyphemia, remnants of lens cortex, vitreous loss, synechia and capsular opacity. Preservation rate of vision was lower significantly in the cases showing signs of synechia, capsular opacity, or remnants of lens cortex than the cases not showing the above signs(p<0.01). There were significant reduction of the complications such as corneal opacity, clot in anterior chamber in the group using I/A device compared to the group in which I/A device was not used(p<0.01). Groups using I/A device showed slightly higher vision than the group not using I/A device (75%; 42%). There were no significant differences in the occurrence rate of complications and the preservative rate of vision between the groups with and without viscoelastic material. The present study indicated that the postoperative complications of posterior synechia, capsular opacity, uveitis and vistreous loss were important factors affecting the vision and that I/A device was applicable to extract the lens cortex and effective to elevate the success rate after ECE in dogs.

  • PDF

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

A Study on the Application of Risk Management for Medical Device Software Test (의료기기 소프트웨어 테스트 위험관리 적용 방안 연구)

  • Kim, S.H.;Lee, jong-rok;Jeong, Dong-Hun;Park, Hui-Byeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.495-497
    • /
    • 2012
  • Development of application risk management for medical device software test. First, Through questionnaires, Medical device manufacturers, Analysis of software validation and risk management status. Second, Analyzed by comparing the difference between black box testing and white box testing. Third, After analyzing the potential for software analysis tools using code derived factors were quantified, Finally, Medical device risk management process so that it can be applied to build the framework by FMEA(Failure Mode and Effect Analysis) technique. Through this Difficult to build software validation and risk management processes for manufacturers to take advantage of support in medical device GMP(Good Manufacture Practice).

  • PDF

New Material Architecture and Its Process Integration for a-Si TFT Array Manufacturing

  • Song, Jean-Ho;Park, Hong-Sick;Kim, Sang-Gab;Cho, Hong-Je;Jeong, Chang-Oh;Kang, Sung-Chul;Kim, Chi-Woo;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.552-555
    • /
    • 2002
  • In order to achieve higher performance and low cost a-Si TFT-LCD panel, new material architecture and its process integration for a-Si TFT array manufacturing method were developed. Material combination of low resistant dry-etchable metal and new pixel electrode under currently adopted 4 mask process made it possible to get more-simplified manufacturing method and better device performance for the a-Si TFT-LCD application. Proposed 4 mask process architecture with optimized wet etchants and dry etching process was applicable to various devices such as notebook, monitor and TV.

  • PDF