• Title/Summary/Keyword: Device

Search Result 29,497, Processing Time 0.055 seconds

Sensor Device Plug & Play for Ubiquitous Computing (유비쿼터스 컴퓨팅을 위한 센서 디바이스 Plug & Play)

  • Park, Jung-Sun;Eun, SeongBae;Yoon, Hyeon-Ju
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.3
    • /
    • pp.151-156
    • /
    • 2012
  • When mounting the sensor device in the way of Plug&Play, sensor device drivers need to be loaded and linked dynamically. Since a sensor node platform is based on small 8 bit MCU, dynamic loading and linking technique used in Windows and Linux can not be applied. In this paper, we present how to link and load dynamically sensor device drivers for sensor device Plug&Play. We implement a prototype and evaluate it to make sure that there is no performance degradation like sensor device driver connection speed and memory usage. Connection speed overhead increases to 0.2ms. Memory usage overhead increases to hundreds byte. It shows that there is no heavy influence in running the actual program.

Estimation of MCG parameters for the diagnosis of heart diseases (심질환 진단을 위한 심자도 파라메터의 추출)

  • Jeon, Chang-Ik;Huh, Young;Kim, Ki-Uk;Han, Byung-Hee;Jin, Seung-Oh;Chang, Won-Suk;Lee, Hyun-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.549-552
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring tangential components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. In this paper, we developed a new analysis method, which is based on the theory of electromagnetic field. We show some differences of the current direction between the normal MCG and the abnormal(ischemic heart disease) MCG.

  • PDF

Design and Implementation of LonWorks/IP Router for Network-based Control (네트워크 기반 제어를 위한 Lonworks/IP 라우터의 설계 및 구현)

  • Hyun, Jin-Waok;Choi, Gi-Sang;Choi, Gi-Heung
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.409-412
    • /
    • 2007
  • Demand for the technology for access to device control network in industry and for access to building automation system via internet is on the increase. In such technology integration of a device control network with a data network such as internet and organizing wide-ranging DCS(distributed control system) is needed, and it can be realized in the framework of VDN(virtual device network). Specifications for device control network and data network are quite different because of the differences in application. So a router that translates the communication protocol between device control network and data network, and efficiently transmits information to destination is needed for implementation of the VDN(virtual device network). This paper proposes the concept of NCS(networked control system) based on VDN(virtual device network) and suggests the routing algorithm that uses embedded system.

  • PDF

Optimization of Device Process Parameters for GaAs-AlGaAs Multiple Quantum Well Avalanche Photodiodes Using Genetic Algorithms (유전 알고리즘을 이용한 다중 양자 우물 구조의 갈륨비소 광수신소자 공정변수의 최적화)

  • 김의승;오창훈;이서구;이봉용;이상렬;명재민;윤일구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.241-245
    • /
    • 2001
  • In this paper, we present parameter optimization technique for GaAs/AlGaAs multiple quantum well avalanche photodiodes used for image capture mechanism in high-definition system. Even under flawless environment in semiconductor manufacturing process, random variation in process parameters can bring the fluctuation to device performance. The precise modeling for this variation is thus required for accurate prediction of device performance. The precise modeling for this variation is thus required for accurate prediction of device performance. This paper will first use experimental design and neural networks to model the nonlinear relationship between device process parameters and device performance parameters. The derived model was then put into genetic algorithms to acquire optimized device process parameters. From the optimized technique, we can predict device performance before high-volume manufacturign, and also increase production efficiency.

  • PDF

Combination-mode BLE Device Profile for Connection & Non-connection Methods

  • Jiang, Guangqiu;Joe, Inwhee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.897-899
    • /
    • 2016
  • In recent years, BLE technology has received extensive attention and has been applied to all aspects of life. The existing BLE device has two methods, one is the connection method, and the other is a non-connection method. The representative profile of the connection method is the proximity file. The most typical example of Non-connection method BLE device is a beacon. However, they are both independent and have their own shortcomings. Connection method device can provide service for only one user, others can't use. Security performance of Non-connection method BLE device is poor and the device can't be controlled by the user. In this paper, a combination-mode BLE device profile design scheme is presented, which combines with the previous two methods, and solves the defaults. And We define a dual purpose advertising package that can be used in a normal environment as well as in a disaster environment. Finally, a unidirectional Control idea is proposed. Through performance evaluation, we found that the device has strong stability and low power consumption.

A Study about XML Application for Integrating Field Device (필드기기 통합구성을 위한 XML 적용에 관한 연구)

  • Moon, Yong-Seon;Lee, Myung-Bok;Jeong, Cheol-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.8
    • /
    • pp.733-739
    • /
    • 2005
  • Device Description that is described as C-based DDL(Device Description Language) should be provided for the control system to use the progressive function of field device in the distributed control system. DD expresses field device function itself and parameter. DD is used to set a necessary function far a control strategy in the central control system. DD technology which was adopted as international standard IEC 61804-Part 2 is being used in PROFIBUS, Foundation Fieldbus and HART. However, the DD is dependent to the fieldbus and it doesn't have a suitable form in the industrial Ethernet. This paper presents the possibility of a change from EDD(Electronic Device Description) and GSD(General Slave Data) used for integrating field devices to XDD(XML for Device Description) and verifies it's effectiveness. Also, this paper presents research assignment on the XML application in the distributional system from now on by examining the possibility of Ethernet`s development in the industrial area.