• 제목/요약/키워드: Deviation angle

검색결과 510건 처리시간 0.035초

협응이동훈련이 특발성 측만증 환자의 척추 외형과 삶의 질에 미치는 효과 : 단일사례연구 (Effect of Coordinative Locomotor Training on Spine Appearance and Quality of Life in Patients with Idiopathic Scoliosis: Single Subject Study)

  • 김진철;오은주
    • 대한물리의학회지
    • /
    • 제16권3호
    • /
    • pp.89-97
    • /
    • 2021
  • PURPOSE: This study examined the effects of coordinative locomotor training on the spine appearance and quality of life of patients with idiopathic scoliosis. METHODS: This study included two patients with idiopathic scoliosis: one with a thoracic and lumbar type scoliosis and the other with thoracic type scoliosis. The study design was a single case study (A-B-A'), with a baseline-intervention/phase-post-intervention. The baseline (A) was designed and measured five times, intervention phase (B) ten times, and post-intervention (A') five times. The coordinative locomotor training program was divided into 10 minutes of warm-up exercise, 30 minutes of the main exercise, and 10 minutes of the finishing exercise, for 50 minutes each time. The primary outcome measurements were measured using the Cobb's angle, Adam's test, and Gait view pro 2.0 to determine the changes in the spine appearance. The secondary outcome measurements were compared before and after using the SRS-22 questionnaire to determine the quality of life of the scoliosis patients. A statistical test analyzed the mean and standard deviation, and the rate of change was presented by a visual analysis method using descriptive statistics and graphs. RESULTS: The findings showed that the spine appearance and quality of life of the two subjects were improved compared to the baseline measurements during the intervention phase, and the improved state was maintained during the post-intervention period. CONCLUSION: These findings indicate that coordinative locomotor training may help improve the spine appearance and quality of life of patients with idiopathic scoliosis.

등가변형을 이용한 테이터 말뚝의 지지력 산정 (Estimation of Axial toad Capacity for Tapered Piles Using Equivalent Transformation)

  • 전성남;서경범;송원준;이준환
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.57-64
    • /
    • 2009
  • 본 연구에서는 등가변형을 이용하며 테이퍼 말뚝의 지지력을 산정하는 방법을 제안하였다. 지반조건과 테이퍼각도를 고려하여 지지력을 산정하던 기존의 방법과 달리, 테이퍼말뚝의 지지력산정시 콘관입시험 결과를 활용하도록 하였다. 이때 테이퍼말뚝은 등가변형을 이용하여 형태를 단순화 시켰으며 이를 통해 실무에서 비교적 쉽게 지지력을 산정 할 수 있는 방법을 제안하였다. 제안된 방법의 검증을 위해 실내시험과 현장시험을 실시하였다. 실내모형시험 결과로부터 측정된 극한지지력과 본 연구에서 제안된 방법에 의한 예측값을 비교한 결과 표준편차는 $0.05{\sim}0.121$, COV는 $0.04{\sim}0.05$의 값을 보여 대체적으로 유사한 결과를 보였으며, 현장시험은 약 2.5%의 오차를 보여 측정값에 근접함을 알 수 있었다. 그 결과 제안된 지지력 산정법은 테이퍼말뚝의 지지력을 비교적 정확하게 예측하는 것으로 나타났다.

Spatial Estimation of soil roughness and moisture from Sentinel-1 backscatter over Yanco sites: Artificial Neural Network, and Fractal

  • Lee, Ju Hyoung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.125-125
    • /
    • 2020
  • European Space Agency's Sentinel-1 has an improved spatial and temporal resolution, as compared to previous satellite data such as Envisat Advanced SAR (ASAR) or Advanced Scatterometer (ASCAT). Thus, the assumption used for low-resolution retrieval algorithms used by ENVISAT ASAR or ASCAT is not applicable to Sentinel-1, because a higher degree of land surface heterogeneity should be considered for retrieval. The assumption of homogeneity over land surface is not valid any more. In this study, considering that soil roughness is one of the key parameters sensitive to soil moisture retrievals, various approaches are discussed. First, soil roughness is spatially inverted from Sentinel-1 backscattering over Yanco sites in Australia. Based upon this, Artificial Neural Networks data (feedforward multiplayer perception, MLP, Levenberg-Marquadt algorithm) are compared with Fractal approach (brownian fractal, Hurst exponent of 0.5). When using ANNs, training data are achieved from theoretical forward scattering models, Integral Equation Model (IEM). and Sentinel-1 measurements. The network is trained by 20 neurons and one hidden layer, and one input layer. On the other hand, fractal surface roughness is generated by fitting 1D power spectrum model with roughness spectra. Fractal roughness profile is produced by a stochastic process describing probability between two points, and Hurst exponent, as well as rms heights (a standard deviation of surface height). Main interest of this study is to estimate a spatial variability of roughness without the need of local measurements. This non-local approach is significant, because we operationally have to be independent from local stations, due to its few spatial coverage at the global level. More fundamentally, SAR roughness is much different from local measurements, Remote sensing data are influenced by incidence angle, large scale topography, or a mixing regime of sensors, although probe deployed in the field indicate point data. Finally, demerit and merit of these approaches will be discussed.

  • PDF

수준별 힘 안정성에 대한 EMG 변인 및 근육 특성의 관여 (Involvement of EMG Variables and Muscle Characteristics in Force Steadiness by Level)

  • 조현덕;김맹규
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권5호
    • /
    • pp.336-345
    • /
    • 2023
  • The present study was designed to evaluate changes in neuromuscular properties and the structural and qualitative characteristics of muscles during submaximal isometric contractions at low-to-relatively vigorous target forces and to determine their influence on force steadiness (FS). Thirteen young adult males performed submaximal isometric knee extensions at 10, 20, 50, and 70% of their maximal voluntary isometric contraction using their non-dominant legs. During submaximal contractions, we recorded force, EMG signals from vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF), and ultrasound images from the distal RF (dRF). Force and EMG standard deviation (SD) and coefficient of variation (CV) values were used to measure FS and EMG steadiness, respectively. Muscle thickness (MT), pennation angle (PA), echo intensity (EI), and texture features were calculated from ultrasound images to assess the structural and qualitative characteristics of the muscle. FS, neuromuscular properties, and texture features showed significant differences across different force levels. Additionally, there were significant differences in EMG_CV among the quadriceps at the 50% and 70% force levels. The results of correlation analysis revealed that FS had a significant relationship with EMG_CV in VM, VL, and RF, as well as with the texture features of dRF. This study's findings demonstrate that EMG steadiness and texture features are influenced by the magnitude of the target force and are closely related to FS, indicating their potential contribution to force output control.

Correlation between cone-beam computed tomographic findings and the apnea-hypopnea index in obstructive sleep apnea patients: A cross-sectional study

  • Marco Isaac;Dina Mohamed ElBeshlawy;Ahmed Elsobki;Dina Fahim Ahmed;Sarah Mohammed Kenawy
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.147-157
    • /
    • 2024
  • Purpose: The aim of this study was to explore the correlations of cone-beam computed tomographic findings with the apnea-hypopnea index in patients with obstructive sleep apnea. Materials and Methods: Forty patients with obstructive sleep apnea were selected from the ear-nose-throat (ENT) outpatient clinic, Faculty of Medicine, Mansoura University. Cone-beam computed tomography was performed for each patient at the end of both inspiration and expiration. Polysomnography was carried out, and the apnea-hypopnea index was obtained. Linear measurements, including cross-sectional area and the SNA and SNB angles, were obtained. Four oral and maxillofacial radiologists categorized pharyngeal and retropalatal airway morphology and calculated the airway length and volume. Continuous data were tested for normality using the Kolmogorov-Smirnov test and reported as the mean and standard deviation or as the median and range. Categorical data were presented as numbers and percentages, and the significance level was set at P<0.05. Results: The minimal value of the cross-sectional area, SNB angle, and airway morphology at the end of inspiration demonstrated a statistically significant association (P<0.05) with the apnea-hypopnea index, with excellent agreement. No statistically significant difference was found in the airway volume, other linear measurements, or retropalatal airway morphology. Conclusion: Cone-beam computed tomographic measurements in obstructive sleep apnea patients may be used as a supplement to a novel radiographic classification corresponding to the established clinical apnea-hypopnea index classification.

Prevalence of malocclusions and parafunctional habits in pediatric patients with developmental dyslexia

  • Federica Guglielmi;Anna Alessandri-Bonetti;Geraldine Gemelli;Linda Sangalli;Patrizia Gallenzi
    • 대한치과교정학회지
    • /
    • 제54권4호
    • /
    • pp.229-238
    • /
    • 2024
  • Objective: The study aimed to assess the prevalence of dental malocclusion, orthodontic parameters, and parafunctional habits in children with developmental dyslexia (DD). Methods: Forty pediatric patients (67.5% boys and 32.5% girls, mean age: 11.02 ± 2.53 years, range: 6-15 years) with DD were compared with 40 age- and sex-matched healthy participants for prevalence of dental malocclusion, orthodontic parameters, and parafunctional habits. Dental examinations were performed by an orthodontist. Results: Pediatric patients with DD exhibited a significantly higher prevalence of Angle Class III malocclusion (22.5% vs. 5.0%, P = 0.024), deep bite (27.5% vs. 7.5%, P = 0.019), midline deviation (55.0% vs. 7.5%, P < 0.0001), midline diastemas (32.5% vs. 7.5%, P = 0.010), wear facets (92.5% vs. 15.0%, P < 0.0001), self-reported nocturnal teeth grinding (82.5% vs. 7.5%, P < 0.0001), nail biting (35.0% vs. 0.0%, P < 0.0001), and atypical swallowing (85.0% vs. 17.5%, P < 0.0001) compared to that in healthy controls. Conclusions: Pediatric patients with DD showed a higher prevalence of Class III malocclusion, greater orthodontic vertical and transverse discrepancies, and incidence of parafunctional activities. Clinicians and dentists should be aware of the vulnerability of children with dyslexia for exhibiting malocclusion and encourage early assessment and multidisciplinary intervention.

젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값 (Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts)

  • 박상배
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.127-134
    • /
    • 2008
  • 본 연구는 조절 및 이향운동 기능장애 분석을 위한 표준 값을 알아보기 위해 시행하였다. 방법: 안질환이 없고 현성사시 및 간헐 사시가 없으며 조절 및 이향운동 기능장애가 없는 54명(평균연령 25.3${\pm}$2.7세)을 대상으로 하였다. 객관적 편위각을 기준으로 하여 폭주근점, 원거리 및 근거리 사위량을 측정하였고 이후 AC/A비, 상대조절력 및 이향운동 기능을 측정한 후 이 값들을 Morgan의 표준값과 비교 분석하였다. 결과: 원거리 및 근거리 사위량은 각각 1.24${\pm}$2.72${\Delta}$, 2.70${\pm}$4.91${\Delta}$이었고 렌즈차 이용법에 의한 AC/A비는 3.92${\pm}$2.17${\Delta}$/D로 Morgan의 표준값과 거의 같은 값을 보였다. 원거리 음성융합성폭주량은 동일한 값을 보인반면, 양성융합성폭주량은 Morgan의 표준값에 비해 7${\Delta}$ 높은 값을 보였다. 근거리의 전체 이향운동의 범위는 Morgan 값과 큰 차이를 보이지 않은 반면 원거리의 전체 이향운동의 범위는 양성융합성폭주여력이 상대적으로 더 넓은 범위를 가지는 것으로 나타났다. 양성상대조절력은 +0.37D 높은 값이었고, 음성상대조절력은 -0.63D 더 높은 값을 보였다. 결론: 본 연구에 의한 양안시 분석 값들은 Morgan의 표준값이 상당한 근접성 폭주를 포함하고 있을 가능성을 나타낸다. Morgan 표준값과 비교하여 한국인을 대상으로 한 원거리 및 근거리 이향운동량과 근접성 폭주량은, 특히 BO limit 값에서 매우 다른 값을 보이고 있기 때문에 만약 Morgan 값을 한국인의 양안시 분석에 그대로 적용한다면 부정확한 양안시 진단으로 유도될 수도 있다. 본 연구의 측정값은 한국인 정상 젊은 성인의 양안시 분석을 위한 자료로 활용될 수 있을 것으로 생각한다.

  • PDF

단안 선택적 레이저섬유주성형술에서 안압 변동을 보정한 성공예측인자의 분석 (Predictors of Success of Selective Laser Trabeculoplasty Adjusted for Intraocular Pressure Variations)

  • 이준석;이종은;서샘;이규원
    • 대한안과학회지
    • /
    • 제59권12호
    • /
    • pp.1166-1172
    • /
    • 2018
  • 목적: 선택적 레이저섬유주성형술(selective laser trabeculoplaty, SLT)을 시행 받은 개방각녹내장 환자에서 치료받지 않은 반대안의 안압을 보정하여 SLT의 안압하강 효과 및 성공예측인자를 분석하고자 하였다. 대상과 방법: 단안에 SLT를 시행 받고 1년 이상 관찰한 개방각녹내장 환자 52명 52안을 후향적으로 분석하였다. 시술 전, 시술 후 1, 2, 3개월, 이후 3개월마다 안압을 측정하였다. 시술 후 안압은 치료받지 않은 반대안의 안압변화량으로 보정하여 계산하였다. SLT의 성공은 시술 전 안압보다 20% 이상 감소한 경우로 정의하였다. Kaplan-Meier 생존분석을 이용하여 성공률을 산출하였고, 성공예측인자를 분석하였다. 결과: 시술 전 평균 안압은 $23.17{\pm}6.96mmHg$, 시술 후 1년째 평균 안압하강은 $5.59{\pm}4.78mmHg$ (29.7%)였으며, 반대안 안압을 보정한 안압하강은 $4.70{\pm}4.67mmHg$ (23.9%)였다. SLT의 성공률은 65.4%, 반대안 안압을 보정한 성공률은 53.9%였다. 시술 전안압만이 SLT 성공과 유의한 상관관계를 보였고, 시술 전 안압이 높을수록 시술 후 안압하강이 크게 나타났다(p=0.025). 나이와 시야검사의 mean deviation은 SLT 성공과 유의한 상관관계가 없었다(p=0.066, p=0.464). 결론: 개방각녹내장 환자에서 SLT는 안전하고 효과적인 치료 방법이며, 시술 전 안압만이 SLT의 성공과 유의한 상관관계를 보였다. 정확한 치료 효과 분석을 위하여 반대안의 안압 변동을 고려하여야 하겠다.

상수리나무 채종원에서 수형목 풍매차대 35가계의 생장 및 가지특성 (Growth and Branch Characteristics of 35 Half-sib Families in a Seed Orchard of Quercus acutissima)

  • 전병환;강규석;한상억;오창영;김장수;김계환
    • 한국육종학회지
    • /
    • 제41권3호
    • /
    • pp.228-235
    • /
    • 2009
  • 상수리나무 실생채종원에서 수형목 풍매차대 35 가계의 생장 및 가지특성 변이에 대한 연구결과를 요약하면 다음과 같다. 채종원 임령 12년생 때의 평균 수고는 9.96 m, 평균 흉고 직경 14.50 cm, 평균 지하고 1.04 m, 평균 수관폭 6.80 m, 평균 가지각도는 $18.82^{\circ}$이었고 평균 통직성 등급은 2.58로 조사되었다. 수고생장에 있어서 075 및 052 가계가 우수하였던 반면에 0511 및 0517 가계는 불량한 것을 나타났다. 또한 흉고직경 생장에 있어서는 075 및 0413 가계가 우수하였고 0725 및 0511 가계가 불량하였다. Pearson 상관 및 Spearman 순위상관 계수는 2006년과 2008년 조사에서 가지각도를 제외한 조사된 모든 형질에 있어서 정의 상관이 있는 것으로 나타났다. 아울러 수고 생장 및 흉고직경 생장이 우수한 가계가 통직성에서도 우수한 것으로 조사되었다. 분산분석 결과, 수고, 흉고직경, 원주재적 및 통직성에 있어 가계간 고도의 유의적인 생장 차이가 있는 것으로 나타났다. 그리고 지하고, 수관폭 및 가지각도에 있어서도 가계간 차이가 인정되었다. 채종원 임령 10년 및 12년의 경우에 개체유전력 보다는 가계유전력이 더욱 높게 추정되었다. 특히 가계유전력이 높게 추정된 수고, 흉고직경 및 통직성은 강한 유전적 영향을 받고 있는 것으로 나타났다. 이러한 결과로부터 개체선발보다는 가계선발에 의하여 더욱 높은 개량효과가 추정됨을 알 수 있었다. 가계선발에 의한 각 조사형질별 개량효과 기대치를 추정한 결과 가지각도에서 개량효과가 가장 높은 것으로 추정되었으며, 그 다음으로 흉고직경, 수고 순이었다. 최종적으로 생장 및 가지특성에 대한 분산분석, 유전력, 유전변이량 등에 근거하여 생장형질별 가중치를 부여하여 가계별 육종가를 추정하였다. 이러한 육종가는 상수리나무 채종원에서 유전간벌을 적용하는데 있어 선발 기준 등 기초 자료로 이용될 수 있을 것이다.

열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가 (The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer)

  • 제영완;나경수;윤일규;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.57-71
    • /
    • 2005
  • 목적 : 전자선을 이용하여 전신피부를 치료할 경우, 조사되는 피부선량과 정확도를 열형광 선량계(TLD)와 반도체(Diode) 검출기를 이용하여 평가하고자 한다. 대상 및 방법 : 본원에 내원한 다발성 발적을 보이는 균상식육종(Mycosis fungoides) 환자를 대상으로 스텐포드 테크닉(Stanford technique)을 시행하였다. 선형가속기의 6MeV 전자선을 SSD 300 cm에서 0.8 cm의 아크릴 스포일러를 사용하여 6개 자세로 각 자세 당 gantry각도 $64^{\circ}.\;90^{\circ}.\;116^{\circ}$로 각각 조사하면서 열형광 선량계와 반도체검출기를 이용하여 환자피부선량과 출력을 동시에 $5{\sim}6$회 측정하였다. 결과 : 열형광선량계의 측정결과 종양선량과 오차는 조사중심부(C.A) $+\;6\%$, 대퇴부(thigh) $+\;8\%$, 배꼽(umbilicus) $+\;4\%$, 종아리(calf) $-\;8\%$, 두정부(vertex) $-\;74.4\%$, 액와부(deep axillae) $-\;10.2\%$, 항문(anus)과 고환(testis) $-\;87\%$, 발바닥(sole) $-\;86\%$로 나타났다. 손톱과 발톱은 4 mm납으로 차폐하여 $+\;4\%$로 나타났다. 반도체검출기의 측정결과 선량오차는 환자조사중심부에서 $-\;4.5\%{\sim}+\;5\%$, 스포일러에 부착한 경우 $-\;1.1\%{\sim}+\;1\%$로 나타났다. 결론 : 열형광선량계의 측정결과, 전신피부의 선량오차는 $+\;8\%{\sim}-\;8\%$로 허용오차인 ${\pm}10\%$의 범위를 만족시키는 선량분포를 보였으며, 저선량 부위에는 여러 개의 열형광선량계로 측정하여 추가선량과 조사야 크기를 결정하여 두정부, 회음부, 양쪽 발바닥에 추가조사 하였다. 스포일러에서 측정한 전자선출력은 안정되었고, 환자조사 중심부에서 측정한 반도체 검출기의 선량오차는 검출기 부착위치재현과 환자자세재현 등에 의해 기인된 것으로 사료된다.

  • PDF