• Title/Summary/Keyword: Deviation angle

Search Result 510, Processing Time 0.023 seconds

Evaluation of Spray Flight Attitude for Agricultural Roll-balanced Helicopter using Kalman Filter (칼만필터를 이용한 농용 균평헬리콥터의 살포비행자세 평가)

  • Park, Hee Jin;Koo, Young Mo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.342-351
    • /
    • 2012
  • Purpose: Aerial spraying with an agricultural unmanned helicopter became a new paradigm in the agricultural practice. Laterally tilting behavior of a conventional agricultural helicopter, resulting in the biased down-wash and uneven spray deposit is a physically intrinsic phenomenon while hovering and cruise flights. Authors studied and developed a roll-balanced agricultural helicopter with a raised pylon tail rotor system. In this study, the attitude of the roll-balanced helicopter was determined using the Kalman filter algorithm, and the quality of roll balancing of a bare-airframe helicopter was evaluated. Methods: Instantaneous attitudes were estimated using the advantage of gyroscope, followed by the long term correction and prediction using accelerometer data for the advantage of convergence. The attitudes of the fuselage were calculated by applying the Kalman filter algorithm. The spraying maneuver of the helicopter was performed at a field of 50 m long, and the attitude data were acquired and evaluated. Results: The determination of attitude using the inertial measurement unit(IMU) and Kalman filter was reliable and practical. The intrinsic attitude of the developed helicopter was stable and roll-balanced. The deviation of roll angle was ${\pm}6.3^{\circ}$ with an average of $0^{\circ}$, referring to roll-balanced. Conclusions: Handling quality of the roll attitude determined to be steadily balanced. The balancing behavior of the developed helicopter would result in an even spray pattern during aerial application.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

A Study of Pedestrian Navigation Service System for Visual Disabilities (시각장애인용 길안내 서비스 시스템에 대한 연구)

  • Jang, Young Gun;Cha, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.315-321
    • /
    • 2017
  • This paper is a study on the design and realization of Pedestrian navigation service system for the visually impaired. As it is an user interface considering visually impaired, voice recognition functioned smartphone was used as the input tool and the Osteoacusis headset, which can vocally guide directions while recognizing the surrounding environment sound, was used as the output tool. Unlike the pre-existing pedestrian navigation smartphone apps, the developed system guides walking direction by the scale of the left and right stereo sound of the headset wearing, and the voice guidance about the forked or curved path is given several meters before according to the speed of the user, and the user is immediately warned of walking opposite direction or proceeding off the path. The system can acquire stable and reliable directional information using the motion tracker with the dynamic heading accuracy of 1.5 degrees. In order to overcome GPS position error, we proposed a robust trajectory planning algorithm for position error. Experimental results for the developed system show that the average directional angle error is 6.82 degrees (standard deviation: 5.98) in the experimental path, which can be stated that it stably navigated the user relatively.

Analysis for Realization of Vertical Wall in Holes by Applying Alternate High Pressure in the Punchless Piercing Process (무 펀치 피어싱 공정에서 교번식 고압 적용을 통한 구멍 내 직벽 구현 해석)

  • Lee, Sang-Wook;Um, Tai-Joon;Joo, Young-Cheol;Kim, Kug-Weon;Kwon, Kye-Si
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.929-934
    • /
    • 2009
  • In this work, the punchless piercing process with application of alternate high pressure has been proposed as a method to obtain pierced holes having nearly vertical wall over thin metal plates. The numerical simulation considering Lemaitre damage model has been accomplished for the proposed method. The simulated results have been compared with those by conventional one-way punch less piercing process. It has been revealed that the fractured section made by pressure alternation method shows nearly steep wall where the deviation angle from the vertical line is as small as $3.6^{\circ}$.

Microstructural Evolution of Ultrafine Grained AA1050/AA6061 Complex Aluminum Alloy Sheet with ARB Process (ARB공정에 따른 초미세립 AA1050/AA6061 복합알루미늄 합금 판재의 미세조직 발달)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 2013
  • The microstructural evolution of AA1050/AA6061 complex aluminum alloy, which is fabricated using an accumulative roll-bonding (ARB) process, with the proceeding of ARB, was investigated by electron back scatter diffraction (EBSD) analysis. The specimen after one cycle exhibited a deformed structure in which the grains were elongated to the rolling direction for all regions in the thickness direction. With the proceeding of the ARB, the grain became finer; the average grain size of the as received material was $45{\mu}m$; however, it became $6.3{\mu}m$ after one cycle, $1.5{\mu}m$ after three cycles, and $0.95{\mu}m$ after five cycles. The deviation of the grain size distribution of the ARB processed specimens decreased with increasing number of ARB cycles. The volume fraction of the high angle grain boundary also increased with the number of ARB cycles; it was 43.7% after one cycle, 62.7% after three cycles, and 65.6% after five cycles. On the other hand, the texture development was different depending on the regions and the materials. A shear texture component {001}<110> mainly developed in the surface region, while the rolling texture components {011}<211> and {112}<111> developed in the other regions. The difference of the texture between AA1050 and AA6061 was most obvious in the surface region; {001}<110> component mainly developed in AA1050 and {111}<110> component in AA6061.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Sports Biomechanical Analysis before and after Applying Weight Belt during Squat Exercise (스쿼트 동작 시 웨이트 벨트 착용 전·후에 따른 운동역학적 분석)

  • LEE, Jeong-Ki;HEO, Bo-Seob;KIM, Yong-Jae;LEE, Hyo-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.893-902
    • /
    • 2016
  • The purpose of this study is to investigate the effect of wearing a weightlifting belt, which is an auxiliary equipment used during squat, by measuring and analyzing biomechanical difference in lower limb and proposing safer and to suggest a more effective exercise method for general population. Selected 8 male participants in their 20s who have not performed regular resistance exercise for at least a year, but have experience of performing squat. The comprehensive method of study is as follows: subjects were notified of the purpose of the study and were told to practice warm-up and the squat motion for the experiment for 20 minutes. When the participant believed they were ready to begin, the experiment was started. At controlled points, foot pressure distribution sensor has been installed. Then left and right feet have been placed on the pressure distribution sensor, from which data for successful squat position that does not satisfy the criteria for failure have been collected and computed with Kwon3D XP program and TPScan program. For data processing of this study, SPSS 21.0 was used to calculated mean (M) and standard deviation (SD) of the analyzed values, and paired t-test has been conducted to investigate the difference before and after wearing the weightlifting belt, with p-value of ${\alpha}<.05$. As for time consumed depending on usage of weightlifting belt in squat, statistically significant difference has been found in P2, which is recovery movement. Lower limb angle depending on usage of weightlifting belt in squat has shown statistically significant difference in E1 foot joint(p<. 001). There has been statistically significant difference in E2 knee joint. Foot pressure percentage depending on usage of weightlifting belt in squat were found to be statistically significant (p<. 01) in both regions of anterior and posterior foot.

A Study on the Development of Torso Pattern for the Schoolgirl of a Tween Generation - Focused on the Elementary School Students of Fifth and Sixth Grades - (트윈세대 여학생을 위한 토르소 원형의 개발에 관한 연구 - 초등학교 5, 6학년을 중심으로 -)

  • Hur Nam-Kyoung;Kim So-Ra
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.3 s.62
    • /
    • pp.387-403
    • /
    • 2006
  • The purpose of this study was to develop a new torso pattern for the schoolgirl of a tween generation who had different somatotype from children and teenagers. The subjects in this study were female elementary school students of fifth or sixth grade. Through a sensory evaluation of four existing torso patterns, the first research torso pattern was developed. Drafting methods of each item, which closed to the optimum value three, were selected. The differences between the values of the selected drafting methods and the optimum three were verified through a Wilcoxon's ranked sum test. The final research torso pattern was developed through adjusting the drafting methods according to the deviation from the optimum value three. The schoolgirl of a tween generation is at the time to show the remarkable breast development compared with a waist circumference, so the bust drafting was defined as B/4+ 1.25cm separately front and back. The drafting of a waist circumference was defined as W/4+1cm separately front and back which taken the ease amounts of the somatotype into consideration of the schoolgirl of a tween generation. A princess line was used instead of a waist dart because their hip circumference was more developed than a waist circumference. The crossed amount of a front hemline was 0.3cm and that of a back hemline was 0.7cm. and the princess line of the position was drawn with a straight line at a right angle of the back waistline. The armhole depth was determined B/4-1cm in consideration of the aesthetic and the trend, although the effective movement of upper arm was required.

  • PDF

A CLINICO-RADIOLOGIC STUDY OF BONY REMODELING OF THE FRACTURED CONDYLES IN CHILDREN (소아에서 골절된 하악과두의 골개조 양상에 관한 임상 및 방사선학적 연구)

  • Cho Jeong-Shin;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.471-482
    • /
    • 1995
  • Bony remodeling pattern of condyle fractures in children are different from in adult for growing of condyle, also might affect treatment and prognosis of the condyle fracture. Subjects of this clinical and radiologic study were 26 temporomandibular joints diagnosed as condyle fracture in 23 patients under 15 years old age. They were treated with conservative method at Dental Hospital of Yonsei University from Jan., 1986 to Oct., 1994. Bony remodeling related with fracture pattern was evaluated. The results obtained are as follows: 1. The ratio of male to female in patients with condyle fracture was 1 : 0.9 and the difference of sex ratio was not noted. Comparing with preschool-age group and school-age group, age frequency was higher in preschool-age group(83%). 2. Fallen down(54%) was the most frequent cause of condyle fractures. Traffic accident and slip down were followed. 3. The most common clinical sign of condyle fractures was tenderness to paipation09 cases). Mouth opening limitation07 cases), swelling(7 cases), malocclusion(3 cases) were next in order. 4. According to sites of condyle fractures, unilateral fractures were in 20 patients and bilateral fractures in 3 patients, therefore total 23 patients-26 cases of condyle fracture were observed. According to fracture distribution, condyle fractures were in 10 patients(44%). Condyle fractures with symphysis fracture(9 patients, 39%), condyle fractures with ascending ramus fracture(2 patients, 9%), condyle fracture with mandibular body fracture(1 patient, 4%), and condyle fractures with mandibular angle fracture(1 patient, 4%) were followed. 5. In displacement pattern of fractured fragment of mandibular condyle, dispiacement(17 cases, 66%) was most common. Dislocation(5 cases, 19%) and deviation (4 cases, 15%) were next in order. 6. During the observation period of fractured condyles, remodeling patterns of fracture sites related with articular fossa were observed with usual condylar shape in 23 cases and with prominently different shape in 3 cases.

  • PDF

Experimental Study of Hydrodynamic Performance of Backward Bent Duct Buoy (BBDB) Floating Wave Energy Converter (부유식 진동수주형 파력발전기(BBDB)의 유체 동역학적 성능 실험 연구)

  • Kim, Sung-Jae;Kwon, Jinseong;Kim, Jun-Dong;Koo, Weoncheol;Shin, Sungwon;Kim, Kyuhan
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.53-58
    • /
    • 2012
  • An experimental study on the hydrodynamic performance of a backward bent duct buoy (BBDB) was performed in a 2D wave tank. The BBDB is one of the promising oscillating water column (OWC) types of floating wave energy converters. Two different corner-shaped BBDBs (sharp-corner and round-corner) were used to measure the maximum chamber surface elevations and body motions for various incident wave conditions, and their hydrodynamic characteristics were compared. In order to investigate the effect of the pneumatic pressure inside the chamber, the heave and pitch angle interacted with elevations were compared for both open chamber and partially open chamber BBDBs. From the comparison study, the deviation in the chamber surface elevations between the two shapes of BBDBs was found to be significant near the resonance period, which may be explained by viscous energy loss. It was also found that the pneumatic pressure noticeably affected the chamber surface elevation and body motions.