• Title/Summary/Keyword: Deviation

Search Result 9,477, Processing Time 0.032 seconds

A Study on the Application of a Dementia Prevention Program and Its Effect Test (치매예방 프로그램 운영 및 효과검증 연구)

  • Hwang, Ok-Nam;Yoon, Sook-Rye;Hwang, Hye-Yeon;Nam, Ki-Seok
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.5 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • The objective of this study was to apply a dementia prevention program to the subjects who were suspected of dementia and test its effect. This study was one group pretest-posttest design. The dementia prevention program was applied for 20 weeks to the 19 subjects who were suspected of dementia after a screen test among 638 subjects enrolled in 10 senior citizen's centers in G city. The scores of self-efficacy, cognition, quality of life were measured before and after the program. The data collected were analyzed using a SPSS (statistical analysis system) program, and frequencies, averages and standard deviations were obtained. The differences of the scores of the pretest and posttest were analyzed with Mann-Whitney test and sign test. The results were as follows: 1. After the program, the average score of self-efficacy was increased from 75.31 (standard deviation 11.99) to 84.26 (standard deviation 13.92). 2. There are no differences between the average scores of physical and psychological quality of life, however, the average score of social quality of life was slightly increased from 2.25 (standard deviation 0.40) to 2.53 (standard deviation 0.43), and the overall score of social quality of life was low. 3. The average score of cognition was significantly increased from 21.00 (standard deviation 2.60) to 24.58 (standard deviation 3.37), thus, it was found that the program was effective to improve the cognition level. 4. The score differences of self-efficacy, quality of life, cognition between the pretest and posttest were statistically significant. 5. The score differences of quality of life between the pretest and posttest were found to be dependent on marital status, exercise and regular checkup yes or no. In conclusion, the program was effective to prevent the subjects suspected of dementia from dementia.

  • PDF

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

Concha bullosa, nasal septal deviation, and their impacts on maxillary sinus volume among Emirati people: A cone-beam computed tomography study

  • Al-Rawi, Natheer H;Uthman, Asmaa T;Abdulhameed, Elaf;Al Nuaimi, Ahmed S;Seraj, Zahra
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.45-51
    • /
    • 2019
  • Purpose: To determine the prevalence of concha bullosa (CB) and nasal septal deviation (NSD) and their impact on maxillary sinus volume (MSV). Materials and Methods: Cone-beam computed tomographic (CBCT) images of 106 Emirati people were used in this study. The direction and angle of septal deviation were calculated. The presence of CB, which could be unilateral, contralateral, or bilateral in relation to the direction of NSD, was also recorded. MSV was measured using reconstructed Digital Imaging and Communication in Medicine images on Dolphin 3D imaging software version 11.8 premium (Dolphin Imaging, Chatsworth, CA, USA). P values<0.05 were considered to indicate statistical significance. Results: CB was detected in 37.7% of the sample; 20.7% of the sample showed single unilateral CB and 16.6% had single bilateral CB. NSD was seen in 74.5% of the sample. In the participants with CB, 45.5% showed mild deviation, 34.4% showed moderate deviation, and only 12.5% showed severe septal deviation. CB, but not NSD, was associated with significantly higher MSV on the affected side (P=0.001). Conclusion: Although NSD was observed in more than two-thirds of the sample and CB was present in more than one-third of the sample, only CB had a significant impact on MSV.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Estimation of Climatological Standard Deviation Distribution (기후학적 평년 표준편차 분포도의 상세화)

  • Kim, Jin-Hee;Kim, Soo-ock;Kim, Dae-jun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.93-101
    • /
    • 2017
  • The distribution of inter-annual variation in temperature would help evaluate the likelihood of a climatic risk and assess suitable zones of crops under climate change. In this study, we evaluated two methods to estimate the standard deviation of temperature in the areas where weather information is limited. We calculated the monthly standard deviation of temperature by collecting temperature at 0600 and 1500 local standard time from 10 automated weather stations (AWS). These weather stations were installed in the range of 8 to 1,073m above sea level within a mountainous catchment for 2011-2015. The observed values were compared with estimates, which were calculated using a geospatial correction scheme to derive the site-specific temperature. Those estimates explained 88 and 86% of the temperature variations at 0600 and 1500 LST, respectively. However, it often underestimated the temperatures. In the spring and fall, it tended to had different variance (e.g., increasing or decreasing pattern) from lower to higher elevation with the observed values. A regression analysis was also conducted to quantify the relationship between the standard deviation in temperature and the topography. The regression equation explained a relatively large variation of the monthly standard deviation when lapse-rate corrected temperature, basic topographical variables (e.g., slope, and aspect) and topographical variables related to temperature (e.g., thermal belt, cold air drainage, and brightness index) were used. The coefficient of determination for the regression analysis ranged between 0.46 and 0.98. It was expected that the regression model could account for 70% of the spatial variation of the standard deviation when the monthly standard deviation was predicted by using the minimum-maximum effective range of topographical variables for the area.

Characteristics of Nasal Trauma in the Implanted Nasal Prosthesis (실리콘 코높임술 후 코 부위 외상의 특징)

  • Choi, Seok Min;Choi, Hwan Jun;Kim, Cheol Hann;Ahn, Hyung Sik;Kang, Sang Gue;Jung, Sung Gyun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.597-602
    • /
    • 2008
  • Purpose: Presently, silicone rubber is chosen most frequently for nasal augmentation. However, there is a possibility of extrusion with this material. Sometimes, noses are prone to be traumatized, and then silicone rubber has a possibility of deformity or deviation resulting in trauma. We experienced cases with complications and traumatic deformities after the augmentation rhinoplasty. Methods: A retrospective review was performed to determine the characteristics of the implanted nasal silicone prosthesis after trauma. The patients' data such as deviation of implant, shape of fracture, age and sex of the patient, time of treatment, operative methods were reviewed. From March 2001 to March 2008, this study was performed in 30 patients. The patients were 25 females and 5 males, from 24 to 60 years of age, with an average of 42. All patients had previous augmentation rhinoplasty with silicone implant. Results: All of the 30 patients were confirmed as deviation of silicone and nasal bone fractures in the facial bone CT scan. The most common cause of fracture was traffic accident. The classification of nasal trauma after augmentation was done by facial bone CT. Class I: Deviation of silicone without nasal bone fracture without extrusion(12 cases, 40%), Class II: Deviation of silicone without nasal bone fracture and with extrusion(4 cases, 13%), Class III: Deviation of silicone with nasal bone fracture and without extrusion(8 cases, 27%), Class IV: Deviation of silicone with nasal bone fracture and with extrusion(3 cases, 10%), Class V: Mild deviation of silicone with nasal bone fracture(3cases, 3%). Specially, the comminuted or trapezoid nasal fracture was confirmed in 11 cases(Class III, IV). Conclusion: The problems of silicone implant have generally been related to foreign body reactions, rigidity of the material, encapsulation, infections, and extrusion. We experienced 11 cases of comminuted or comminuted trapezoid shaped fracture below nasal implant. So, we think this phenomenon could be used in late problem of silicone implant.

Denoising on Image Signal in Wavelet Basis with the VisuShrink Technique Using the Estimated Noise Deviation by the Monotonic Transform (웨이블릿 기저의 영상신호에서 단조변환으로 추정된 잡음편차를 사용한 VisuShrink 기법의 잡음제거)

  • 우창용;박남천
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.2
    • /
    • pp.111-118
    • /
    • 2004
  • Techniques based on thresholding of wavelet coefficients are gaining popularity for denoising data because of the reasonable performance at the low complexity. The VisuShrink which removes the noise with the universal threshold is one of the techniques. The universal threshold is proportional to the noise deviation and the number of data samples. In general, because the noise deviation is not known, one needs to estimate the deviation for determining the value of the universal threshold. But, only for the finest scale wavelet coefficients, it has been known the way of estimating the noise deviation, so the noise in coarse scales cannot be removed with the VisuShrink. We propose here a new denoising method which removes the noise in each scale except the coarsest scale by Visushrink method. The noise deviation at each band is estimated by the monotonic transform and weighted deviation, the product of estimated noise deviation by the weight, is applied to the universal threshold. By making use of the universal threshold and the Soft-Threshold technique, the noise in each band is removed. The denoising characteristics of the proposed method is compared with that of the traditional VisuShrink and SureShrink method. The result showed that the proposed method is effective in denoising on Gaussian noise and quantization noise.

  • PDF

Result Analysis according to Population Distribution Trends when Reagents are Changed (시약 변경 시 모집단 분포 추이에 따른 결과 분석)

  • Hye-Mi Park;Soo-Yeon Lim;Sun-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

Asymptotics in Load-Balanced Tandem Networks

  • Lee, Ji-Yeon
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.155-162
    • /
    • 2003
  • A tandem network in which all nodes have the same load is considered. We derive bounds on the probability that the total population of the tandem network exceeds a large value by using its relation to the stationary distribution. These bounds imply a stronger asymptotic limit than that in the large deviation theory.

  • PDF