• Title/Summary/Keyword: Deviation

Search Result 9,403, Processing Time 0.047 seconds

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

The Non-Destructive Determination of Heavy Metals in Welding Fume by EDXRF (EDXRF에 의한 용접흄 중의 중금속의 비파괴 정량)

  • Park, Seunghyun;Jeong, Jee Yeon;Ryoo, Jang Jin;Lee, Naroo;Yu, Il Je;Song, Kyung Seuk;Lee, Yong Hag;Han, Jeong Hee;Kim, Sung Jin;Park, Jung sun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.229-234
    • /
    • 2001
  • The EDXRF(Energy Dispersive X-ray Fluorescence Spectrometer) technique was applied to the determination of heavy metals in welding fume. The EDXRF method designed in this study was a non-destructive analysis method. Samples were analyzed directly by EDXRF without any pre-treatment such as digestion and dilution. The samples used to evaluate this method were laboratory samples exposed in a chamber connected with a welding fume generator. The samples were first analyzed using a non-destructive EDXRF method. The samples subsequently were analyzed using AAS method to verify accuray of the EDXRF method. The purpose of this study was to evaluate the possibility of the non-destructive analysis of heavy metals in welding fume by EDXRF. The results of this study were as follow: 1.When the samples were collected under the open-face sampling condition, a surface distribution of welding fume particles on sample filters was uniform, which made non-destructive analysis possible. 2. The method was statistically evaluated according to the NIOSH(National Institute for Occupational Safety and Health) and HSE(Health and Safety Executive) method. 3. The overall precision of the EDXRF method Was calculated at 3.45 % for Cr, 2.57 % for Fe and 3.78 % for Mn as relative standard deviation(RSD), respectively. The limits of detection were calculated at $0.46{\mu}g$/sample for Cr, $0.20{\mu}g$/sample for Fe and $1.14{\mu}g$/sample for Mn, respectively. 4. A comparison between the results of Cr, Fe, Mn analyzed by EDXRF and AAS was made in order to assess the accuracy of EDXRF method. The correlation coefficient between the results of EDXRF and AAS was 0.9985 for Cr, 0.9995 for Fe and 0.9982 for Mn, respectively. The overall uncertainty was determined to be ${\pm}12.31%$, 8.64 % and 11.91 % for Cr, Fe and Mn, respectively. In conclusion, this study showed that Cr, Fe, Mn in welding fume were successfully analyzed by the EDXRF without any sample pre-treatment such as digestion and dilution and a good correlation between the results of EDXRF and AAS was obtained. It was thus possible to use the EDXRF technique as an analysis method of working environment samples. The EDXRF method was an efficient method in a non-destructive analysis of heavy metals in welding fume.

  • PDF

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Effect of Enzyme Replacement Therapy on Growth in Korean Patients with Mucopolysaccharidosis Type I (I형 뮤코다당증 환자들에서 효소 보충 요법이 성장에 미치는 영향)

  • Huh, Rimm;Cho, Sung Yoon;Chang, Mi Sun;Lee, Jieun;Kwun, Younghee;Kim, Su Jin;Sohn, Young Bae;Park, Sung Won;Maeng, Se Hyun;Kwon, Eun-Kyung;Han, Sun Ju;Jung, Jooyoun;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.13 no.2
    • /
    • pp.111-119
    • /
    • 2013
  • Purpose: Mucopolysaccharidosis type I (MPS I) is a lysosomal storage disorder caused by deficiency of the enzyme ${\alpha}$-L-iduronidase, which leads to a broad spectrum of multisystemic manifestations. Short stature and decreased growth velocity are prominent features of MPS I. The aim of the present study was to evaluate the effect of enzyme replacement therapy (ERT) on growth of Korean MPS I patients from a single center. Methods: Height data were obtained by retrospective chart review of 10 Korean patients with MPS I who had received ERT for a minimum of 3 years. Height was expressed as standard deviation scores (SDS) based on normative data. Annual growth rates were calculated before and during ERT. A piecewise regression model was used to analyze height z-scores before and after treatment. Individual analysis was performed for impact of phenotype [(severe (Hurler) versus attenuated (Hurler-Scheie, Scheie)] on growth. Results: Annual growth was 3.3 cm (z-score= -0.21) in the year before ERT and 6.2 cm (z-score= 0.17), 5.8 cm (z-score= 0.07), and 3.8 cm (z-score= -0.4) in the first, second, and third years of ERT, respectively. Regression analysis showed improvement in the slope after ERT (difference= 0.04; P=0.022). Estimated slope differences between severe and attenuated phenotypes were statistically significant before (P=0.001) and after treatment (P<0.0001), although no significant difference was noted when stratified by phenotype. Conclusion: ERT with aldurazyme appears to have a positive impact on linear growth in patients with MPS I.

  • PDF

The Effect of Spiritual Nursing Intervention on Anxiety of the Hospice Patients (영적 간호중재가 호스피스 환자의 불안에 미치는 효과)

  • Yoon, Mae-Ok
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 2001
  • Purpose : Surveying the effects on drop the anxiety of the hospice patients in spiritual nursing intervention with a quasi-experimental design using non-equivalent contrast group non-synchronized design to try in order to give the support which provide a holistic and individualizational nursing to comfort of hospice patients. Method : The results of survey were collected from 67 patients(67 subjects comprised 37 hospice patients of the experimental group and 30s of contrast) who were given hospice care from July to September of 2000 at the General Hospital in Cheon Ju city. The tool was used Spielberger's State Anxiety Scale, and the difference in the level of dropping anxiety among patient groups was analyzed with the mean, standard deviation, $x^2-test$. t-test and paired t-test. The spiritual nursing intervention was carried out through Hymn, Scripture, prayer, the therapeutic use of self over a period of three weeks. Results : 1) In general characters, men were a many more of the objects and the average age of the experimental and contrast group was 59.6, 55.9 respectively. The family of living together was $2{\sim}3$ members of most part. 2) There were not significant differences in the general, disease and therapeutic, religional characters between the experimental and contrast group. 3) The majority of the objects were cancer patients in disease and therapeutic characters(Experimental : 92%, Contrast : 95%). 4) After the spiritual nursing intervention state anxiety of the experimental group were remarkably lower than those of the contrast (t=-5.987, P=0.000). 5) Decreasing rate in the anxiety scores of before and post facto of the experimental group were remarkably lower than those of the contrast (t=6.237, P=0.000). Conclusion : The hospice patients who were offered spiritual nursing intervention became much lower than those who were not offered it in anxiety. Spiritual nursing intervention can be suited to field with one program of an effective that that relieved their anxieties. It is not only a very short time but has quite a little findings in part of spiritual nursing intervention. Therefore, further study in this field is necessary to concrete and substantial investigate in order to more and more increasing hospice patients in 21st century.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Effects on senior fitness, cognitive function and daily living activity of female elderly with light dementia by continuous and intermittent exercises (연속적.간헐적 운동이 경증치매 여성고령자의 기능적 체력, 인지기능 및 일상생활수행능력에 미치는 영향)

  • Kang, Joo-Seong;Jeang, Il-Hong;Yang, Jum-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4234-4243
    • /
    • 2010
  • Dementia such as poor concentration, anxiety and tension makes it hard to continue exercise in reality. For this, intermediate exercise is suggested in this study. And the study investigates the effects on senior fitness, cognitive function(MMSE-K) and daily living activity(ADL) by continuous exercise and intermittent exercise, which helps to provide proper exercise treatment to them. For this, female elderly patients at A dementia hospital in B Metropolitan city are selected and they have been diagnosed with possible Alzheimer's disease according to DSM-IV. Among them, six(6) are grouped for continuous exercise and five(5) for intermediate exercise, total 11 people are finally tested. They are given hand&foot exercise, Korean folk dance and band exercise three times a week for the total 12 weeks. The continuous exercise group does their exercise one time of 30 minutes a day while the intermediate exercise group for three times of each 10 minute a day. For the result, SPSS Ver. 18.0 is used to get mean value(M) and standard deviation(SD) and in order to verify the interaction effect between exercise group and time, two-way repeated ANOVA is applied and statistical significance level is set at .05. The result shows that there is significant difference in time between senior fitness and cognitive function. But there is no significant difference in group and time${\times}$group. And there is no significant difference in time, group and time${\times}$group for daily living activity. Continuous exercise group and intermediate exercise group both have the similar effects. That does not mean that intermediate exercise is the best for all people with dementia, but in terms of exercise time, intermittent exercise may be effective for patients of light dementia.

Relative efficacy of three Ni-Ti file systems used by undergraduates (학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교)

  • Kim, Hyeon-Cheol;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.38-48
    • /
    • 2005
  • The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems - $ProFile^{(R)}$ (PF), Manual $ProTaper^{(R)}$ (MPT), Rotary $ProTaper^{(R)}$ (RPT). Every student prepared 3 simulated root canals with each system respectively. After root canal preparation, the Ni-Ti files were evaluated for distortion or breakage Assessments were made according to the presence of various types of canal aberrations. The pre- and post-instrumented canal images were attained and superimposed. The instrumented root canal width were measured and calculated for the net transportation (deviation) and the centering ratio. Under the condition of this study, both $ProTaper^{(R)}$ systems allowed significantly more removal of root canal wall than the $ProFile^{(R)}$ system. In the important other aspects such as the centering ratio, there was no significant differences between the systems. Novice dental students were able to prepare curved root canals with any kinds of Ni-Ti file systems with little aberration and great conservation of tooth structure. Students want to learn effective methods and at the same time simple rotary procedures. The rotary $ProTaper^{(R)}$ systems were one of the most compatible to these students from the point of view of cutting ability The $ProFile^{(R)}$ system was also compatible in safe and gentle shaping.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.