• Title/Summary/Keyword: Development Test

Search Result 18,941, Processing Time 0.061 seconds

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Studies on the grassland Development in the Forest V. Effect of sharing degrees on the early growth characteristics and winter survival of main grasses (임간초지 개발에 관한 연구 V. 차광정도가 주요 초목의 초기생육과 월동에 미치는 영향)

  • Park, M.S.;Seo, S.;Han, Y.C.;Lee, J.Y.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.6 no.1
    • /
    • pp.38-43
    • /
    • 1986
  • This field experiment was conducted to determine the effects of shading degrees (0 : full sunlight, 25, 50 and 75%) on the early growth characteristics and winter survival of grasses. For the test different artificial shading houses were established and pasture species used were orchardgrass, timothy and perennial ryegrass. The experiment was performed at Livestock Experiment Station in Suweon, and sowing date was Aug. 25, 1984. The results are summarized as follows : 1. Generally, root length, new root length, number of new root and tillers of grasses were increased at 0% (full sunlight) of shading, followed by 25, 50 and 75% of shading degrees, in that order. Plant length and leaf elongation, however were increased at 50% of shading, followed by 75, 25 and 0%. 2. The percentage of winter killing of grasses was significantly (P<0.05) increased as the shading degrees increased. Also the percentages of winter killing were 10.1% in orchardgrass, 9.5% in timothy and 14.2% in perennial ryegrass, respectively. 3. A significant negative correlations were observed in the relationship between winter killing and tillers, new root length and number of new root of grasses. However, there were positive correlations between winter killing and plant length or leaf elongation under shading conditions. 4. As the shading degrees are increased by 0, 25, 50 and 75%, the NAR of grasses was tended to be decrease to 10.98, 11.52, 9.81 and 6.12 g/$m^2$/day, in that order. Also there was a negative correlation (r=-0.5943*) between winter killing and NAR of grasses, and NAR of orchardgrass, timothy and perennial ryegrass were 8.58, 8.53 and 11.71 g/$m^2$/day, respectively.

  • PDF

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Establishment of PCR Conditions for the Identification of Stenotrophomonas maltophilia Isolated from Boar Semen and Antimicrobial Susceptibility Patterns of the Isolates (돼지 정액에서 분리된 Stenotrophomonas maltophilia 확인을 위한 PCR 기법 개발 및 분리 균주의 항생제 감수성 양상)

  • Jung, Byeong-Yeal;Park, Bum-Soo;Kim, Ha-Young;Byun, Jae-Won;Kim, Ae-Ran;Jeon, Albert Byung-Yun;Kim, In-Cheul;Chung, Ki-Hwa
    • Journal of Life Science
    • /
    • v.22 no.8
    • /
    • pp.1114-1119
    • /
    • 2012
  • Bacteria are frequently contaminated during the collection and processing procedures of boar semen. Of the contaminants, Stenotrophomonas (S.) maltophilia is a Gram-negative bacterium that is widely distributed in a variety of habitats. Although PCR assays have been developed for the detection of S. maltophilia, they cross-react with some species of Xanthomonas. In this study, we designed a primer set for the detection of S. maltophilia in order to target the chiA (GenBank accession no. NC_010943) gene. The specific PCR products were amplified from S. maltophilia only, not from other tested strains that are frequently found in semen. The detection limit of the PCR was $1.5{\times}10^3$ CFU/ml with pure-cultured S. maltophilia and $1.5{\times}10^4$ CFU/ml with S. maltophilia spiked in semen. Twenty-six (5.9%) S. maltophilia were isolated from 440 semen samples. The PCR results exhibited 98.9% agreement with a comparison of S. maltophilia isolation. Also, the sensitivity and specificity of the PCR were 100% and 98.7%, respectively. In the antimicrobial susceptibility test, S. maltophilia isolates were highly susceptible to enrofloxacin and florfenicol, while the majority of them were resistant to amoxicillin/clavulanic acid, apramycin, ceftiofur, penicillin, and spectinomycin. These results indicated that the PCR using the chiA gene was proven to be reliable and effective for the detection of S. maltophilia with high levels of sensitivity and specificity.

A Study on the Applicability of Chinese Steamed Dumpling with Korean Food Stuffing - Focusing on Jiangsu Residents - (중국 만두소의 한국음식 적용가능성 연구 - 중국 강소성 지역 주민을 대상으로 -)

  • Wu, Di;Joo, Nami
    • Korean journal of food and cookery science
    • /
    • v.31 no.3
    • /
    • pp.344-351
    • /
    • 2015
  • The purpose of this study is to improve Korean food market competitiveness in China, and to develop product diversity. Therefore, the paper will discuss and analyze the feasibility of combining Korean and Chinese cuisines. The paper is based on a SPSS-analyzed survey of 255 Jiangsu residents focusing on the concept of breakfast, and the recognition of and preference for Korean food. The result showed a high level of eating out for breakfast in Jiangsu province and the expectation of many options. The respondents generally preferred porridge, steamed stuffed dumplings, noodles and other options that are relatively convenient. Korean foods such as bulgogi, samgyeopsal, tteokbokki and bibimbap generally enjoyed a high degree of recognition and preference. This study selected bulgogi, jeyukbokkeum, dakgalbi and japchae as the stuffings for steamed dumplings and an evaluation of sensory attributes including saltiness, sweetness, spiciness, and gravy was conducted using 30 professionals. Relatively high scores were recorded in all aspects. Compared with the reference product, the dumplings with Korean food stuffing achieved higher scores. As a new development and attempt, the steamed dumplings with Korean food filling evaluated during this test demonstrated feasibility and enormous market potential. The study provides a new direction and reference value for the Chinese breakfast market and for the penetration of Korean food into the Chinese market.

Antioxidant activity and quality characteristics of black sesame gruel added with glutinous rice, glutinous brown rice and, glutinous black rice powder (찹쌀, 찹쌀현미, 찰흑미 가루를 첨가한 흑임자죽의 항산화활성 및 품질특성)

  • Park, Jung-Lee
    • Korean journal of food and cookery science
    • /
    • v.29 no.5
    • /
    • pp.581-590
    • /
    • 2013
  • This study investigated the quality characteristics and antioxidant effects of black sesame gruel made with different concentrations of 15 minutes of treatment at $100^{\circ}C$ roasted black sesame. Total lignans showed the highest levels with 15 minutes of treatment at $100^{\circ}C$ roasted black sesame. With regard to lecithin's antioxidant effects, 15 minutes of treatment at $100^{\circ}C$ roasted black sesame showed a higher oxidation restriction rate. Hydroxyl radical scavenging, a similar scavenging activity to tocopherol, and a comparatively higher scavenging activity than sesamol, was shown with 15 minutes of treatment at $100^{\circ}C$ roasted black sesame and showed scavenging abilities of 90% and higher. For black sesame gruels, roasting can be used in a variety of ways in cooking in order to enhance functionality and preference. The most appropriate ratios of $100^{\circ}C$, 15minutes roasted black sesame in black sesame gruels, with regard to the overall quality characteristics, are as follows: The results of the sensory test showed that the overall preference was highest for glutinous rice-black sesame gruel, glutinous brown rice-black sesame gruel, and glutinous black rice-black sesame gruel, which were deemed best with 50% black sesame. From the above results, it could be seen that glutinous rice, glutinous brown rice, and glutinous black rice black sesame gruels, which are made by adding 50% roasted black sesame, contributed to enhancing the function of antioxidant activation and development quality.

A Clinicopathologipal Study on the Prognosis of IgA Nephropathy in Children (소아 IgA 신병증의 예후와 관련한 임상병리학적 고찰)

  • Kwon Jae-Hun;Choi Eun-Na;Park Jee-Min;Jeung Hyeun-Joo;Lee Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 2003
  • Purpose : This study was performed to determine the natural history of histologically confirmed IgA nephropathy in pediatric patients who presented with hematuria and proteinuria. Patients and Methods : We reviewed the clinical course of 57 patients diagnosed with IgA nephropathy at the age of 15 years or younger from 1981 to 2000. All patients presented with hematuria or minimal proteinuria($<40\;mg/m^2/day$) and had normal renal function and blood pressure at the time of renal biopsy. Based on the clinical and pathological findings at the time of diagnosis, we sought for complications of IgA nephropathy such as heavy proteinuria(${\ge}40\;mg/m^2/day$), hypertension, and chronic renal failure. Results : The mean age at presentation was $9.5{\pm}2.8$ years(4 to 15 years) and 42(74%) were male. Isolated gross hematuria was observed in 20 patients(35%), microscopic hematuria in 3(5%), minimal proteinuria in 4(7%), both gross hematuria and minimal proteinuria in 15(26%), and both microscopic hematuria and minimal proteinuria in 15(26%). During a median follow-up of $7.0{\pm}3.5$ years, 38(67%) had complete resolution of hematuria and proteinuria, 12(21%) had persistently abnormal urinalysis without development of adverse events. Only 7(12%) developed adverse events : 4(7%) developed severe proteinuria, 1(2%) became hypertensive, and 2(3%) developed Impaired renal function. By univariate analysis using the chisquare test, the age at presentation(>10 years)(P<0.01) and poor histological classes of the Lee or Haas classification at onset(P<0.05) were significantly correlated with adverse events, whereas sex and clinical signs at onset were less concordant. Conclusion : We can conclude that the prognosis of IgA nephropathy diagnosed in early childhood is better and a good correlation exists between the clinical manifestations of this disease and the histological classes.

  • PDF

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.