• Title/Summary/Keyword: Development Scale

Search Result 7,414, Processing Time 0.041 seconds

Effect of Resistance Training on Skeletal Muscle Gene Expression in Rats: a Beadarray Analysis (저항성 운동이 골격근 유전자 발현에 미치는 영향: Beadarray 분석)

  • Oh, Seung-Lyul;Oh, Sang-Duk
    • Journal of Life Science
    • /
    • v.23 no.1
    • /
    • pp.116-124
    • /
    • 2013
  • The aim was to examine resistance exercise-related genes after 8 weeks of resistance training. Thirty-two male Sprague-Dawley rats were divided into four groups: 4 weeks sedentary (4 wks CON, n=8), 8 weeks sedentary (8 wks CON, n=8), 4 weeks exercise training (4 wks REG, n=8), and 8 weeks exercise training (8 wks REG, n=8). The rats were trained to climb a 1-m vertical incline (85-degree), with weights secured to their tails. They climbed 10 times, 3 days per week, for 8 consecutive weeks. Skeletal muscle was taken from the flexor halucis longus after the exercise training. After separating the total RNA, large-scale gene expression was investigated by beadarray (Illumina RatRef-12 Expression BeadChip) analysis, and qPCR was used to inspect the beadarray data and to analyze the RNA quantitatively. The detection p-value for the genes was p<0.01, the M-value {M=$log_2$(condition)-$log_2$(reference)} was >1.0, and the DiffScore was >20. In total, the expression of 30 genes significantly increased 4 weeks after the exercise training, and the expression of six genes decreased. At 8 weeks, the expression of five genes significantly increased and that of 12 decreased. Several genes are potentially involved in resistance exercise and muscle hypertrophy, including 1) regulation of cell growth (IGFBP1, PLA2G2A, OKL38); 2) myogenesis (CSRP3); 3) tissue regeneration and muscle development (MUSTN1, MYBPH); 4) hypertrophy (CYR61, ATF3, NR4A3); and 5) glucose metabolism (G6PC, PCK1). These results may help to explain previously reported physiological changes of the skeletal muscle and suggest new avenues for further investigation.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

A Study on Comparative Analysis of Socio-economic Impact Assessment Methods on Climate Change and Necessity of Application for Water Management (기후변화 대응을 위한 발전소 온배수 활용 양식업 경제성 분석)

  • Lee, Sangsin;Kim, Shang Moon;Um, Gi Jeung
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • In order to resolve the problem of change in global climate which is worsening as days go by and to preemptively cope with strengthened restriction on carbon emission, the government enacted 'Framework Act on Low Carbon Green Growth' in 2010 and selected green technology and green industry as new national growth engines. For this reason, the necessity to use the un-utilized waste heat across the whole industrial system has become an issue, and studies on and applications of recycling in the agricultural and fishery fields such as cultivation of tropical crops and flatfishes by utilizing the waste heat and thermal effluent generated by large industrial complexes including power plants are being actively carried out. In this study, we looked into the domestic and overseas examples of having utilized waste heat abandoned in the form of power plant thermal effluent, and carried out economic efficiency evaluation of sturgeon aquaculture utilizing thermal effluent of Yeongwol LNG Combined Cycle Power Plant in Gangwon-do. In this analysis, we analyzed the economic efficiency of a model business plan divided into three steps, starting from a small scale in order to minimize the investment risk and financial burden, which is then gradually expanded. The business operation period was assumed to be 10 years (2012~2021), and the NVP (Net Present Value) and economic efficiency (B/C) for the operation period (10 years) were estimated for different loan size by dividing the size of external loan by stage into 80% and 40% based on the basic statistics secured through a site survey. Through the result of analysis, we can see that reducing the size of the external loan is an important factor in securing greater economic efficiency as, while the B/C is 1.79 in the case the external loan is 80% of the total investment, it is presumed to be improved to 1.81 when the loan is 40%. As the findings of this study showed that the economic efficiency of sturgeon aquaculture utilizing thermal effluent of power plant can be secured, it is presumed that regional development project items with high added value can be derived though this, and, in addition, this study will greatly contribute to reinforcement of the capability of local governments to cope with climate change.

  • PDF

A Study on the Characteristic of Pollutants of Water Quality and Sediments in Gul-po Stream Basin (굴포천 유역 내 수질 및 퇴적물의 오염물질 특성 파악에 관한 연구)

  • Ahn, Tae-Woong;Jung, Jae-Hoon;Kim, Tae-Hoon;Kim, Sea-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.495-503
    • /
    • 2012
  • The water quality of Gul-po Stream, the subject of this study, has been deteriorating because of the inflow of domestic sewage and the industrial wastewater due to industrialization and the problems relating to the structure of river including slow flow rate and the covering of river. In particular, the domestic sewage from small-medium sized factories by the river and large-scale industrial complex by the upper and middle streams of the river, and the domestic sewage from increasing population due to the regional development are the main pollution sources. Thus, this study aims to survey the water quality and the sediment affecting Gul-po Stream; monitor the state of pollution in water body; assess the yield of sediment and investigate the water quality of river and the problems arising from sediment; and then suggest reasonable ways to improve the situation. The findings from surveying pollution load shows the discharge increases up to average 72.8 times from the upper stream to the downstream of Gul-po Stream, and pollution load increases up to: SS 111 times, BOD 150 times, COD 145 times, the nutrient T-N 222 times and T-P 312 times on an average basis. As for the pollution concentration range, ignition loss is 1.29~12.43%; COD is 4,015~37,547 kg/day; T-N and T-P 94.8~352.5 kg/day and 81.8~372.3 kg/day, respectively. As for the releasing rate of sediment, T-N is -14.46~$156.61mg/m^2/day$; T-P is -11.53~$26.10mg/m^2/day$, indicating the likelihood of internal contamination due to the elution of sediment. This study is expected to be used as basic data to manage Gul-po Stream basin.

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).

A Study on the Temperature fronts observed in the South-West Sea of Korea and the Northern Area of the East China Sea (한국 남$\cdot$서해 및 동중국해 북부해역에 출현하는 수온전선)

  • YANG Young Jin;KIM Sang Hyun;RHO Hong Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.695-706
    • /
    • 1998
  • SST (Sea Surface. Temperature) fronts which were found in the South-West Sea of Korea and the northern area of the East China Sea were examined in order to clarify their positions, shapes, seasonal changes and the formation mechanism, For this study used SST data rearranged from the SST IR image during 1991 to 1996 and oceanographical data obtained by National Fisheries Research and Development Institute. Temperature front in the Cheju Strait was analyzed by the data obtained from a fisheries guidance ship of Cheju Provincial Government, The coastal frontal zone in the South-West Sea of Korea and the offshore frontal zone in the northern area of the East China Sea can be divided into several types (Type of Winter, Summer, Spring, Autumn and late Autumn), Short term variations of SST fronts have a tendency not to move to any Bleat extent for several days. The location of the frontal zone in the southwestern sea of Cheju Island changes on a much large scale than that of the one in the southern coast of Korea, The frontal Tone, formed every year in the southern sea of Korea approaches closer to the coastal area in winter, and moves closer to the south in spring and autumn. The frontal zone of the southwestern sea of Cheju Island moves in a westerly direction from the east, and reaches its most westerly point in the winter and its most easterly point in the summer related to the seasonal change of the Tsushima Current. Additionally, the frontal zone of the southwestern sea of Korea becomes extremely weak in March, April and November. SST fronts are formed every year around the line connecting Cheju Island to Yeoseo Island or to Chungsan Island in the Cheju Strait. A Ring-shaped tidal mixing front appears along the coastal area of Cheju Island throughout the year except during the months from November to January. Especially, in May and October fronts are formed between the coastal waters of Cheju Island and the Tsushima currents connecting the frontal zone of the coastal region in the southern sea of Korea with that of the southwestern sea of Cheju Island.

  • PDF

Numerical Analysis of Unstable Combustion Flows in Normal Injection Supersonic Combustor with a Cavity (공동이 있는 수직 분사 초음속 연소기 내의 불안정 연소유동 해석)

  • Jeong-Yeol Choi;Vigor Yang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.91-93
    • /
    • 2003
  • A comprehensive numerical study is carried out to investigate for the understanding of the flow evolution and flame development in a supersonic combustor with normal injection of ncumally injecting hydrogen in airsupersonic flows. The formulation treats the complete conservation equations of mass, momentum, energy, and species concentration for a multi-component chemically reacting system. For the numerical simulation of supersonic combustion, multi-species Navier-Stokes equations and detailed chemistry of H2-Air is considered. It also accommodates a finite-rate chemical kinetics mechanism of hydrogen-air combustion GRI-Mech. 2.11[1], which consists of nine species and twenty-five reaction steps. Turbulence closure is achieved by means of a k-two-equation model (2). The governing equations are spatially discretized using a finite-volume approach, and temporally integrated by means of a second-order accurate implicit scheme (3-5).The supersonic combustor consists of a flat channel of 10 cm height and a fuel-injection slit of 0.1 cm width located at 10 cm downstream of the inlet. A cavity of 5 cm height and 20 cm width is installed at 15 cm downstream of the injection slit. A total of 936160 grids are used for the main-combustor flow passage, and 159161 grids for the cavity. The grids are clustered in the flow direction near the fuel injector and cavity, as well as in the vertical direction near the bottom wall. The no-slip and adiabatic conditions are assumed throughout the entire wall boundary. As a specific example, the inflow Mach number is assumed to be 3, and the temperature and pressure are 600 K and 0.1 MPa, respectively. Gaseous hydrogen at a temperature of 151.5 K is injected normal to the wall from a choked injector.A series of calculations were carried out by varying the fuel injection pressure from 0.5 to 1.5MPa. This amounts to changing the fuel mass flow rate or the overall equivalence ratio for different operating regimes. Figure 1 shows the instantaneous temperature fields in the supersonic combustor at four different conditions. The dark blue region represents the hot burned gases. At the fuel injection pressure of 0.5 MPa, the flame is stably anchored, but the flow field exhibits a high-amplitude oscillation. At the fuel injection pressure of 1.0 MPa, the Mach reflection occurs ahead of the injector. The interaction between the incoming air and the injection flow becomes much more complex, and the fuel/air mixing is strongly enhanced. The Mach reflection oscillates and results in a strong fluctuation in the combustor wall pressure. At the fuel injection pressure of 1.5MPa, the flow inside the combustor becomes nearly choked and the Mach reflection is displaced forward. The leading shock wave moves slowly toward the inlet, and eventually causes the combustor-upstart due to the thermal choking. The cavity appears to play a secondary role in driving the flow unsteadiness, in spite of its influence on the fuel/air mixing and flame evolution. Further investigation is necessary on this issue. The present study features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous works. In particular, the oscillatory flow characteristics are captured at a scale sufficient to identify the underlying physical mechanisms. Much of the flow unsteadiness is not related to the cavity, but rather to the intrinsic unsteadiness in the flowfield, as also shown experimentally by Ben-Yakar et al. [6], The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The work appears to be the first of its kind in the numerical study of combustion oscillations in a supersonic combustor, although a similar phenomenon was previously reported experimentally. A more comprehensive discussion will be given in the final paper presented at the colloquium.

  • PDF

The Clinical Significance of STAT-PAK ULTRA FAST$^{(R)}$ and ICT Tuberculosis$^{(R)}$ for Serologic Diagnosis of Tuberculosis (폐결핵 진단을 위한 STAT-PAK ULTRA FAST$^{(R)}$와 ICT Tuberculosis$^{(R)}$의 유용성에 관한 연구)

  • Kim, Geun-Hwa;Park, Hee-Sun;Kim, Myung-Hoon;Kang, Dong-Won;Lee, Kyu-Seung;Ko, Dong-Seok;Suh, Jae-Chul;Jeong, Seong-Su;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.311-320
    • /
    • 1999
  • Background: In recent years, tuberculosis has re-emerged as a major health problem in both industrialized & developing countries. Recent advances in identifying & purifying antigens secreted in active tuberculosis infection have lead to the development of serological assays based on a number of immunodominant antigens. To date, the most sensitive and specific of these antigens has been the 38-kDa antigen. Method: Two rapid membrane-based serologic assays using antigen(38-kDa) from mycobacterium tuberculosis for the diagnosis of tuberculosis were evaluated in 22 patients with smear-positive pulmonary tuberculosis, 14 patients with inactive pulmonary tuberculosis, and 9 patients with non-tuberculous lung disease. Result: The evaluation of validity(sensitivity, specificity, positive predictive value, negative predictive value, false positivity and false negativity) of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 28.6%, 63.0%, 44.4%, 71.4 %, and 22.7% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis, respectively. The evaluation of validity of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 33.3%, 73.9%, 37.5%, 66.7%, and 22.7% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 57%, 66.7%, 44.4%, 42.9%, and 45.5% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 100%, 100%, 47.4%, 0%, and 45.4% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. Conclusion: We concluded no effectiveness of STAT-PAK ULTRA FAST$^{(R)}$ & ICT tuberculosis$^{(R)}$on serologic diagnosis of pulmonary tuberculosis. In the future, further large-scale study should be needed for serologic diagnosis of pulmonary tuberculosis.

  • PDF

Pleural Fluid Analysis in Tuberculous Pleurisy Progressing into Severe Pleural Thickening Underwent Pleural Decortication (심한 흉막비후로 진행하여 흉막박피술을 시행받은 결핵성 흉막염 환자들의 흉막액 분석)

  • Chung, Jae Ho;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Chung, Kyung Young;Kim, Sung Kyu;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.353-360
    • /
    • 2003
  • Background : Although most patients with tuberculous pleurisy respond well to anti-tuberculous drugs, some are known to progress into severe pleural thickening which needs decortication despite adequate anti-tuberculous treatment. Therefore, the purpose of this study was to identify factors associated with the development of severe pleural thickening in patients who finally underwent pleural decortication in tuberculous pleurisy. Patients and Methods : From retrospective medical records review, 121 patients initially diagnosed as tuberculous pleurisy without initial pleural fluid loculation were enrolled between January 1998 and December 2002. They were separated into two groups: 85 patients in group 1 who improved by anti-tuberculous drugs only, and 36 patients in group 2 who had progressed into pleural adhesion and finally underwent pleural decortication despite adequate (more than 6 months) anti-tuberculous treatment. Results : Males were more common in group 2 (M/F=31/5) than in group 1 (M/F=53/32) (p=0.010). Group 2 patients tended to have lower pleural fluid glucose level ($58{\pm}4$ mg/dL) than group 1 ($89{\pm}3$ mg/dL) (p=0.001) and higher pleural fluid adenosine deaminase level ($86{\pm}5$ IU/L) than group 1 ($76{\pm}3$ IU/L), (p=0.038). There were no significant differences in age, symptom duration, pleural fluid amount, or pleural fluid LDH level between groups 1 and 2. Conclusions : There was a relative risk of tuberculous pleurisy progression into severe pleural thickening which needed decortication in the case of male patients, low pleural fluid glucose or high adenosine deaminase level. But further, large-scale, prospective studies should be investigated.

Analysis of Sawmill Productivity and Optimum Combination of Production Factors (제재생산성(製材生産性)과 적정생산요소투입량(適正生産要素投入量) 계측(計測))

  • Cho, Woong Hyuk
    • Journal of Korean Society of Forest Science
    • /
    • v.32 no.1
    • /
    • pp.29-35
    • /
    • 1976
  • In order to estimate sawmill productivities, rates of technical change and optimum combination of production factors, Cobb-Douglas production functions have been derived using data obtained from 96 sample mills in Busan-Incheon, southwestern and northeastern areas. The results may be summarized as follows: 1. There is a tendency of expanding average sawmill size in the areas. The horse-power holdings per mill have been increased at the rates of 91 percent in Busan-Incheon, 7.7 percent in southwestern and 16.9 percent in northeastern areas. This implies that the mills around log-importing ports have made rapid development, compared with those in forest regions. 2. The regression coefficients (production elasticities) of the functions for the year of 1967 in the above three areas are much similar each other, but significant differencies are found in the production functions of 1975. In other words, sawmill productivity was mainly restricted by capital deficiencies in all areas in 1967, but this situation was succeeded only by N-E area in 1975. The range of sum of regression coefficients is 1.0437-1.4214, this indicates increasing rates of return to scale. 3. The annual rates of technical changes in B-I, S-W and N-E areas for the observed period are 17.6, 7.6 and 2.2 percents respectively. Busan-Incheon is the only area where labor productivity is higher than that of capital. 4. The best combination of production factors for maximizing firm's profit is subject to the changes of input and output prices. With some assumptions of prices and costs, the optimum levels of power and labor input in B-I, S-W and N-E areas are 57:17, 427:94 and 192:27.

  • PDF