• Title/Summary/Keyword: Determination method

Search Result 6,616, Processing Time 0.033 seconds

Sexual Size Dimorphism and Morphological Sex Determination in the Black-billed Magpie in South Korea (Pica pica sericea)

  • Lee, Sang-Im;Jang, Hyun-Joo;Eo, Soo-Hyung;Choe, Jae-Chun
    • Journal of Ecology and Environment
    • /
    • v.30 no.2
    • /
    • pp.195-199
    • /
    • 2007
  • Statistical tools for determining sex in the sexually monomorphic black-billed magpie based on morphological characters have been developed based on studies of European and North American populations. However, since no morphological method has been developed for black-billed magpies in Korea, it has been difficult to conduct field studies that require information about the sex of individuals. We present two discriminant equations for determining sex of second-year (SY) and after-second-year (ASY) magpies in north- and midwestern part of South Korea. Based on morphological measurements on 105 SY (56 females, 49 males) and 72 ASY (36 females, 36 males) individuals, we found body mass, wing chord, and head length to be the most useful features for morphological sex determination. The accuracy of our method was 86.5% for SYs and 93.1% for ASYs, which is similar to values reported previously from American and European magpies. Since the equations contain morphological traits which are only minimally susceptible to seasonal variation and measurement errors, our discriminant equations should be both useful and robust for sex determination on black-billed magpies in the northern and mid-western regions of South Korea.

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

Development Strategy of Orbit Determination System for Korea's Lunar Mission: Lessons from ESA, JAXA, ISRO and CNSA's Experiences

  • Song, Young-Joo;Ahn, Sang-Il;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.247-264
    • /
    • 2014
  • In this paper, a brief but essential development strategy for the lunar orbit determination system is discussed to prepare for the future Korea's lunar missions. Prior to the discussion of this preliminary development strategy, technical models of foreign agencies for the lunar orbit determination system, tracking networks to measure the orbit, and collaborative efforts to verify system performance are reviewed in detail with a short summary of their lunar mission history. Covered foreign agencies are European Space Agency, Japan Aerospace Exploration Agency, Indian Space Research Organization and China National Space Administration. Based on the lessons from their experiences, the preliminary development strategy for Korea's future lunar orbit determination system is discussed with regard to the core technical issues of dynamic modeling, numerical integration, measurement modeling, estimation method, measurement system as well as appropriate data formatting for the interoperability among foreign agencies. Although only the preliminary development strategy has been discussed through this work, the proposed strategy will aid the Korean astronautical society while on the development phase of the future Korea's own lunar orbit determination system. Also, it is expected that further detailed system requirements or technical development strategies could be designed or established based on the current discussions.

Variable Selection for Logistic Regression Model Using Adjusted Coefficients of Determination (수정 결정계수를 사용한 로지스틱 회귀모형에서의 변수선택법)

  • Hong C. S.;Ham J. H.;Kim H. I.
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.2
    • /
    • pp.435-443
    • /
    • 2005
  • Coefficients of determination in logistic regression analysis are defined as various statistics, and their values are relatively smaller than those for linear regression model. These coefficients of determination are not generally used to evaluate and diagnose logistic regression model. Liao and McGee (2003) proposed two adjusted coefficients of determination which are robust at the addition of inappropriate predictors and the variation of sample size. In this work, these adjusted coefficients of determination are applied to variable selection method for logistic regression model and compared with results of other methods such as the forward selection, backward elimination, stepwise selection, and AIC statistic.

A Study on Effects of Wireless Devices using Similar Frequency for Location Determination Precision (동일한 주파수 대역을 사용하는 무선기기가 측위 정확도에 미치는 영향)

  • Jang, Jung-Hwan;Jang, Jing-Lun;Kwon, Hyeok-Cheol;Li, Guang-Zhu;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.305-311
    • /
    • 2014
  • Recently, though it was developed several services using the context-awareness technology of IoT, there exist also obstacles for high quality service. Specifically it is short the study for uncertainty of context-awareness. This study focused on understanding the effect of frequency interference among several environmental factors for location determination to increase precision of location determination. It was found that frequency interference between devices using 2.4Ghz frequency effect on the location determination precision. It was resulted that frequency interference increase the error of location determination precision. Then, we confirmed that it was required the suitable compensation method corresponding to frequency interference.

Real-Time Determination of Relative Position Between Satellites Using Laser Ranging

  • Jung, Shinwon;Park, Sang-Young;Park, Han-Earl;Park, Chan-Deok;Kim, Seung-Woo;Jang, Yoon-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.351-362
    • /
    • 2012
  • We made a study on real-time determination method for relative position using the laser-measured distance data between satellites. We numerically performed the determination of relative position in accordance with extended Kalman filter algorithm using the vectors obtained through nonlinear equation of relative motion, laser simulator for distance measurement, and attitude determination of chief satellite. Because the spherical parameters of relative distance and direction are used, there occur some changes in precision depending on changes in relative distance when determining the relative position. As a result of simulation, it was possible to determine the relative position with several millimeter-level errors at a distance of 10 km, and sub-millimeter level errors at a distance of 1 km. In addition, we performed the determination of relative position assuming the case that global positioning system data was not received for long hours to see the impact of determination of chief satellite orbit on the determination of relative position. The determination of precise relative position at a long distance carried out in this study can be used for scientific mission using the satellite formation flying.

The Determination of Elastic Constant for Ceramic Forming Material by Hybrid Method (하이브리드 방법에 의한 세라믹 성형재료의 탄성계수 결정)

  • Park Myong Kyun;Koo Bon Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.1
    • /
    • pp.211-222
    • /
    • 2005
  • The ceramic forming materials are getting more important recently since they are used widely in repairing metal structures, welded metal structures and mechanical components etc. The determination of elastic constants for ceramic coating materials takes much time and efforts in experiment due to the brittleness of ceramic material itself. The aim of this research is to determine the Young's Modulus for ceramic metal coating material. In order to achieve the goal, the hybrid method which uses impulse hammer technique for experimental method and modal analysis of finite element method for computational method was used. The results show good agreement with existing experimental data on Young's Modulus.

Determination of Isomaltooligosaccharides in Yoghurts by Using HPLC-ELSD (HPLC-ELSD를 이용한 발효유 제품 중의 Isomaltooligosaccharides 분석법 개발)

  • Ko, Jinhyouk;Lee, Moon-Seok;Kwak, Byung-Man;Ahn, Jang-Hyuk;Park, Jong-Su;Kwon, Joong-Ho
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.417-424
    • /
    • 2013
  • A rapid and simple analytical method for the determination of 9 isomaltooligosaccharides (IMO) species in yoghurts was developed using dispersive solid phase extraction (dSPE) clean-up technic and high performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD). In this study, 9 IMO were extracted from samples simply with chemical reagent using ISO22662 IDF198 method and additional dSPE clean-up. The optimum instrument conditions for the determination were used carbohydrate ES $5{\mu}$ column with gradient elution of water and acetonitrile and ELS detector. The linearity of this method was expressed as the correlation coefficient ($r^2$), the results of IMO 9 species were shown in 0.9999. LOD and LOQ were respectively 7.9-22.1 mg/kg, 25.9-72.8 mg/kg. The accuracy of intra- and inter-day measurements were in the range from $84.3{\pm}4.5$ to $104.9{\pm}6.5%$, and the preceision of the intra- and inter-day measurements were in the range from 0.8 to 7.7%. The recoveries were from $84.3{\pm}4.5$ to $104.9{\pm}6.5%$. The determination results of IMO 9 species for the 9 yoghurts circulated in the market were in the range from $0.317{\pm}0.007$ to $1.624{\pm}0.050$ g/100 g. The newly developed method is appropriate for the determination of IMO in yoghurts, is a rapid and simple method with excellent resolution in compared with previous method.

Determination of Lead in Urine by Atomic Absorption Spectrophotometry (원자흡광법을 이용한 요중 연 배설량의 정량)

  • Paik, Nam-Won;Yoon, Bock-Sang;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.377-381
    • /
    • 1974
  • Determination of lead in urine is important in industrial hygiene and toxicology. Dithizone method has been principally used for the determination of lead in urine, which gives accurate results in skilful hands but is usually complex and time-consuming. Atomic absorption spectrophotometry is a new simple method and several procedures have been described. However, the influences of pH and the presence of chelating agents during treatment of lead poisoning are not clear. The purpose of this study was to find out the effect of pH and chelating agents on the determination of lead using Shimadzu atomic absorption/flame spectrophotometer, model AA-610. The results obtained were as follows: 1. The atomic absorption spectrophotometry(AAS) could be applied without prior acid digestion to specimens in the absence of chelating agents. The absorbance at $2,170\;{\AA}$, though more sensitive, was more noisy electronically. Therefore, we selected the wavelength of $2,833\;{\AA}$ plus scale expansion. 2. The optimal pH was in the range from 2 to 3. 3. The sensitivity was $0.075{\mu}g/ml/%$ and detection limit was about $0.2{\mu}g/ml$. 4. In the presence of EDTA, lead could not be completely determined without prior acid digestion. 5. On specimens from patients receiving penicillamine therapy, a comparison was made between the values obtained with dithizone method and AAS method with prior acid digestion. The results of comparison showed a very good agreement.

  • PDF

Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME) (HF-LPME를 이용한 수용액 시료중의 카페인 분석)

  • In, Chi-Yeon;Kim, Taek-Jae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.84-92
    • /
    • 2008
  • A method for the determination of trace amount of caffeine in urine and various drink samples using hollow fiber-liquid phase microextraction (HF-LPME) and capillary gas chromatograph/nitrogen phosphorus detector (GC/NPD) has been established. HF-LPME method has been optimized with respect to several experimental parameters including the effects of the hollow fiber length, extraction solvent, stirring mode, pH and salt concentration for the determination of caffeine from aqueous samples. The correlation coefficient of calibration curve for caffeine was 0.9994. The average recovery was 102%(n=3). The established method is feasible for the determination of trace amounts of caffeine in several aqueous sample. The limit of detection (LOD) and the limit of quantitation (LOQ) have been found to be 2.5 and 10 ng/mL, respectively. The established HF-LPME method for the analysis of caffeine from aqueous sample can be used for the determination of biological, food and environmental samples.