• Title/Summary/Keyword: Determination method

Search Result 6,607, Processing Time 0.035 seconds

Comparison of methods for Determination of Aflatoxins in food Products (식품중 Aflatoxin 측정방법의 비교)

  • 김면희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 1996
  • A procedure for the determination of Aflatoxins in food and grains which utilizes reversed phased liquid chromatographic (LC) analysis with postcolumn derivatization by an electrochemical cell and determination with a fluorescence detector has been evaluated. The LC mobile phase was water-acetonitrile-methanol (6+2+2) with 1mM KBr and 1 mM HNO3 which gave baseline separation for the four Aflatoxins (AfB1, AfB2, AfG1, AfG2). The electrochemical cell set at 7V, generated bromine and derivatized aflatoxins B1 and G1, The derivatives were detected by the fluorescence detector. The aflatoxins in naturally contaminated corn samples were isolated by three different cleanup procedures: the AOAC method I column(CB method), a rapid filtrate column (Romer's column), and an immunoaffinity column. The final extract were quantitated with fluordensitometric TLC and the LC postcolumn derivatization techniques. The results were quite similar, however the LC technique showed less interferences and could be automated. Samples of corn, raw peanuts, peanut butter and dried dates were also analyzed successfully with this procedure.

  • PDF

Study on the Age Determination in Korean Adult Teeth by Gustafson에s Method (Gustafson 방법에 의한 한국인 영구치에서의 연령감정에 관한 연구)

  • 김동원;김종열
    • Journal of Oral Medicine and Pain
    • /
    • v.9 no.1
    • /
    • pp.103-116
    • /
    • 1984
  • Randumly sampled out 157 extracted Korean adult teeth, aged 12 to 79 years, was applicated to estimat the age by Gustafson's method, were evaluated and analyzed in terms of phyological aging change. The results are as follows : 1. It was reconfirmed that there existed comparatively close correlationship between age and score, especially in old age. 2. Korean score had comparatively high level than those of European. 3. In the probability of age edetermination, the estimation error was the most high level in the age of 70~ with ±4.47, and next order was in the age of 10-19 with ±5.20,60-69 with ±5.8,30-39 with ±5.98,50-59 ±6.20,40-49 with ±6.72,20-29 with ±9.28.Mean value was ±8.03. 4. The regression equation is as follows. y=3.55x+8.52(r=8.75) standard deviation σ=±8.03 (y= estimated age x=score) 5. In age determination with those data, needs to estimate slightly lower than caculated age in range of 10-49, and higher in 50-70 for the real age determination.

  • PDF

Isolation and Quantitative Determination of Berberine and Coptisine from Tubers of Corydalis ternata (들현호색으로부터 Berberine과 Coptisine의 분리 및 함량분석)

  • Lee, Hyang-Yi;Kim, Chong-Won
    • Korean Journal of Pharmacognosy
    • /
    • v.30 no.3
    • /
    • pp.332-334
    • /
    • 1999
  • Corydalis Tuber has been used in traditional medicine for an analgesic, antispasmodic and gastric ulcers. For the quality control on this drug, isolation and quantitative determination of berberine and coptisine from Corydalis ternata Nakai (Papaveraceae) has been conducted by using HPLC method. Berberine and coptisine in quarternary alkaloidal fraction from the crude drug were separated on silicagel column using a $CHCl_3:MeOH\;(85:15)$ and $CHCl_3:MeOH:H_2O\;(70:30:4)$ as an eluent, and the average contents were about 0.93 and 0.36%.

  • PDF

Isolation and Quantitative Determination of Dioscin from Smilacis Chinae Radix (토복령(土茯令, Smilacis Chinae Radix)으로부터 Dioscin의 분리 및 함량분석)

  • Seo, Jung-Hak;Lee, Joo-Mi;Kwon, Soon-Jin;Chang, Seung-Yeup;Lee, Kyong-Soon;Son, Kun-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.32 no.2 s.125
    • /
    • pp.153-156
    • /
    • 2001
  • The methods for isolation and quantitative determination of dioscin, a spirostanol triglycoside, from the roots of Smilax china have been developed. Isolation of dioscin was achieved by silica gel and RP-18 chromatography. The HPLC method used for quantitative determination of dioscin enabled the standardization of the crude drug. It suggests that the content of dioscin in Smilax china should be above 0.01%.

  • PDF

ACTIVATION ANALYSIS OF ENVIRONMENTAL SAMPLES USING THE MT-25 MICROTRON OF THE FLNR

  • Maslov, O.D.;Belov, A.G.;Starodub, G.Ya.;Dmitriev, S.N.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.815-820
    • /
    • 1995
  • Instrumental neutron and gamma activation analysis of coal and combustion products, determination of platinum content in natural samples by radiochemical gamma activation analysis and high-sensitive track method of thorium determination has been studied with the use of the MT-25 microtron.The optimal conditions for complete elemental analysis of coal and combustion products, isolation and determination of platinum and thorium are recommended.

  • PDF

Determination of Selenium and Tellurium by HG-AAS in Foods

  • Cha, Ki-Won;Park, Sang-Ho;Park, Kwang-Won
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.419-425
    • /
    • 1995
  • A method has been investigated for the determination of selenium and tellurium in Ginseng, Ganoderma and Garlic using hydride generation atomic absorption spectrometry(HG-AAS). The concentration effects of hydrochloric acid and sodium tetrahydroborate on the hydride generation for the determination of selenium and tellurium were investigated. The method of sample decomposition was also investigated using various mineral acids, such as nitric, perchloric and sulfuric acid in the closed system, and foreign ion effects containing in the samples were studied. The calibration curves of selenium and tellurium were obtained in the range of 0~40 ppb. The detection limits(S/N=2) of selenium and tellurium are 0.1 and 0.2 ppb. Analytical data of selenium and tellurium in Garlic, Ganoderma and Ginseng are 289, 296 and 198 ng/g for selenium and 146, 127 and 110 ng/g for tellurium, respectively.

  • PDF

Determination of Ba-140 in Fission Products by Substoichiometry (Substoichiometry 법에 의한 Ba-140의 핵붕괴수률의 결정)

  • Park, Keung-Shik;Lee, Chul
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.3
    • /
    • pp.113-115
    • /
    • 1965
  • In previous paper, the determination procedure of fission products mainly consists of many steps which are usually derived from classical analysis schemes. In the present paper a simple and more rapid method of the determination of fission products by means of a smaller amount of reagent than that correspond to the stoichiometric ratio of element to be determined is investigated. The yield of Ba-140 in fission products is determined by this method.

  • PDF

Determination of Catecholamines and Their Metabolites in Rat Brain by High Performance Liquid Chromatography with Electrochemical Detector (HPLC-ECD에 의한 흰쥐 뇌 부위별 Catecholamine 및 대사산물의 신속정량법)

  • Ro, Ihl-Hyeob
    • YAKHAK HOEJI
    • /
    • v.32 no.1
    • /
    • pp.50-54
    • /
    • 1988
  • A simple and sensitive method was studied for the simultaneous determination of catecholamine, indoleamine and their related metabolites by high performance liquid chromatography with electrochemical detector. Norepinephrine, dopamine, serotonin and their metabolites of 3,4-dihydroxyphenylacetic acid, homovanillic acid, 5-indoleacetic acid were resolved from rat brain tissue homogenates by separation on reversed phase $C_{18}$ column with mobile phase consisting of monochloroacetate buffer (pH2.47), 1.42mM sodium octyl sulfonate and 7% acetonitrile. Both catechols and indoles can be eluted in 15min. The sensitivities of this method are sufficient for determination of at least 100 pg of neurochemical amines in brain samples, for example, frontal cortex, olfactory bulb, striatum, septum, hippocampus, thalamus, hypothalamus, medulla & pons and cerebellum. The highest level of dopamine was observed in striatum whereas norepinephrine and serotonin were in hypothalamus.

  • PDF

Determination of Silver with Mercaptans (III). Amperometric Titration of Silver with 2-Mercaptothiazoline (Mercapto 화합물에 의한 은의 정량 (제3보). 2-Mercaptothiazoline에 의한 은의 전류적정)

  • Young Gu Ha
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.6
    • /
    • pp.439-443
    • /
    • 1973
  • 2-Mercaptothiazoline is very sensitive reagent for silver, which have been used for highly selective amperometric determination of silver. A method is described for the determination of micro-quantity of silver by amperometric titration with 2-mercaptothiazoline in ammonical solution. Direct titration of milligram amount of silver (0.05∼1.00mg) is possible in the presence of a number of foreign ions in ammonical solution containing ethylenediaminetetraacetic acid as masking agent under atmosphere. The interfering elements are gold and platinum. The milligram amounts of silver can be determined by the proposed method within an error ${\pm}$5%.

  • PDF

The Optimal Analytical Method for the Determination of PCE and TCE by GC/FID with SPME technieque (고체상미량분석법(SPME)을 이용한 GC/FID에서 PCE 및 TCE 최적 분석법)

  • Ahn Sang-Woo;Lee Si-Jin;Chang Soon-Woong
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.903-909
    • /
    • 2004
  • A new method based on solid phase microextraction(SPME), coupled with GC/FID, has been developed for the determination of PCE and TCE in water samples. The experimental parameters affecting the SPME process (i.e, kinds of fibers, extraction time, desorption time, extraction temperature, volume ratio of sample to headspace, salt addition, and magnetic stirring) were optimized. The coefficients of determination ($R^2$) for PCE and TCE were 0.9951 and 0.9831, respectively when analytes concentration ranges from 10 to 300$\mu$g/L. The relative standard deviations were 3.4 and $2.1\%$ for concentration of 10$\mu$g/L(n=5), respectively. The detection limits of PCE and TCE were 0.5 and l.3$\mu$g/L, respectively.