• 제목/요약/키워드: Deterioration factors

검색결과 650건 처리시간 0.025초

노화로 인한 신체적 기능 쇠퇴와 고령자를 위한 욕실 디자인 가이드라인 관계 연구 (A Study on Relations between Deterioration of Physical Functions due to Aging and Bathroom Design Guidelines for the Elderly)

  • 이연숙;임현진;이지혜;안창헌
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.188-198
    • /
    • 2013
  • Advancement toward aging society has presented the importance of house planning in consideration of the elderly, increasing the necessity of such planning. Therefore the importance of indoor design guideline for elderly houses has been stressed and the understanding of the aging in regard to this trend will create more mature spaces. In line with this trend the purpose of this study is to study the medical factors related with bathroom interior design guidelines of the existing elderly houses from the viewpoint of deteriorating physical functions due to aging process. In order to research the deterioration of physical functions due to aging literatures of medical and exercise physiology were used and concerning the existing bathroom design guidelines for the aged people, the guideline items of behavior facilitation, physiological maintenance and perceptual maintenance aspects out of Murtha & Lee's user benefit criteria(1976) related with physical functions were selected to research in relation with the knowledge about the deterioration phenomena of physical functions. Physical aging and deterioration aspects were classified from the viewpoint of musculoskeletal disorder, cardiovascular disorder, respiratory disorder, gastronomy disorder, urology disorder, somatosensory disorder, endocrine disorder, immune disorder, nervous disorder and skin diseases and these were utilized in interpreting total 100 items of bathroom design guideline. Because bathroom is the space where many physical movements are done, it had the closest relationship with the deterioration of musculoskeletal health in general and as bathroom is the space where people use water and feel the difference in temperature and moisture more than other spaces, deterioration of skin and somatosensory health had the next closest relationship. The result of this study revealed that regarding the deterioration of physical functions of the elderly people in aspect of their perceptibility as designers will design creatively and sincerely based on its relationship with nervous system in future, the result of this study will be used to develop better spatial designs efficiently to meet for the aging society.

화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가 (Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy)

  • 이찬영;이상훈;박진환
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.53-61
    • /
    • 2009
  • 본 연구에서는 강교 도장재료로 사용될 수 있는 에폭시 하도 도료를 도포한 시험편을 촉진시험을 통해 열화시킨 후 도막의 외관 평가 및 EIS에 의한 평가를 실시하고, 그 2가지 방법에 대한 비교 분석을 실시하였다. 화상처리 기법에 의해 구한 총 열화 면적율과 열화도 평점 산정 결과를 상호 비교해 본 결과 녹이 발생한 경우가 그렇지 않은 경우보다 열화도 평점이 높게 나타났다. 이는 강교 도장의 열화도 평가 기준에서 단위 열화 면적율당 부여하는 열화도 평점이 박리의 경우보다 녹의 경우가 더 크기 때문이다. 열화 면적율과 EIS 측정 데이터를 비교해 본 결과 녹의 면적율 약 0.1% 이상, 블리스터링의 면적율 약 3% 이상만 되어도 도막의 임피던스는 약 $10^4{\Omega}{\cdot}cm^2$ 혹은 그 이하로 크게 저하되었다. 2개의 시험편을 제외한 모든 시험편에 대해 전하전달저항(charge transfer resistance, $R_{ct}$)과 이중층 정전용량(double layer capacitance, $C_{dl}$) 값이 나타났으며, 이 결과로부터 이들 시험편들은 도막과 강재 계면에 수분이 축적되어 부식이 진행되고 있음을 알 수 있었다. 열화도 평점과 EIS 측정결과를 상호 비교해 본 결과 저주파수(10 mHz)에서의 임피던스 값이 $10^6{\Omega}{\cdot}cm^2$ 이하로 떨어진 경우는 모두 열화도 평점이 10점 이상으로 나타났으며, NORSOK cyclic test 과정에 의해 열화시킨 경우 열화도 평점이 높지 않음에도 불구하고 임피던스는 가장 낮게 나타났다. 이것은 도장계와 열화조건이 주 시험편과 다르기 때문인 것으로 판단되며, 열화조건이 더 가혹하거나 복합적일 경우 외관 상태에 비해 도막의 저항이 더 크게 저하될 가능성이 있다고 생각된다.

재가치매노인의 인지장애 영향 요인 (Factors Influencing Cognitive Impairment in Elders with Dementia Living at Home)

  • 하은호;박경숙
    • 기본간호학회지
    • /
    • 제18권3호
    • /
    • pp.317-327
    • /
    • 2011
  • Purpose: The purpose of this study was to contribute data toward prevention from advancing dementia and also prevention of deterioration in cognitive impairment by constructing an optimal prediction model and verifying factors influencing cognitive impairment in elders with dementia who reside at home. Methods: The participants in this study were 351 elders who were registered at dementia day care centers in 11 regions of Metropolitan Incheon. Collected data were analyzed using SPSS Statistics 17.0 and SAS 9.1. Bootstrap method using the Clementine program 12.0 was applied to build an optimum prediction model. Results: Gender and education (general characteristics), alcohol, urinary/fecal incontinence, exercise, weight, and ADL (state of health), and depression (psychological state) were found to have an affect on cognitive impairment in these elders. Conclusion: Study results indicate nine key factors that affect cognitive impairment of elders with dementia who reside at home and that could be useful in prevention and management nursing plans. These factors could also be used to expand the role of nurses who are working in community day care centers, and can be applied in the development and provision of various programs to aid retention and improve cognitive function as well as preventing deterioration of cognition.

수침목재의 재질분석에 관한 연구-미시형태적 변화를 중심으로 (MICROMORPHOLOGICAL ASPECTS OF HARDWOODS DETERIORATED IN THE SEA-WATER FROM WRECKED SHIP'S TIMER)

  • 김윤수;최광남
    • 보존과학연구
    • /
    • 통권7호
    • /
    • pp.246-264
    • /
    • 1986
  • Micoromorphological alterations of sea-waterlogged woods by marinemicro-oragnisms were investigated by the light and scanning electron microscopy as a part of serial investigations on the shipwrecked materials which were excavated at the sea shore of Wando-Kun, southern coast of Korea in 1984.Deterioration of sea-waterlogged wood by marine microorganisms were varied with the wood species. The degree of deterioration even in the same wood specieswas different according to the part where it was in mud of sea-water. However, the resistance of Torreya nucifera over the marine organisms was marked. Deterioration in cell wall may be classified into three types; thinning of cell wall, separation of secondary wall from compound middle lamella and tunneling of cell wall. Thinning and separation were frequently observed, while the tunneling was rare. Among the wood cell elements of hardwoods, vessel wall was the least deteriorated. The difference degree of degradation of cell wall constituents and the accumulation of inorganic substances in cell lumen indicate that some factors to be considered for the conservation treatment were discussed. The kinds of marine microorganisms invading and/or inhabiting in wrecked wooden ship were also discussed.

  • PDF

Transient Neurologic Deterioration after Total Removal of Parasagittal Meningioma Including Completely Occluding Superior Sagittal Sinus

  • Oh, In-Ho;Park, Bong-Jin;Choi, Seok-Keun;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권1호
    • /
    • pp.71-73
    • /
    • 2009
  • In surgical planning of the parasagittal meningioma, invasion and occlusion of the superior sagittal sinus are important factors. When tumor is located within anterior 1/3, or when angiographic finding shows total occlusion of superior sagittal sinus, it is regarded that the ligation of superior sagittal sinus is safe. We report a case of parasagittal meningioma in 59-year-old male patient with complete occlusion of superior sagittal sinus which was confirmed by preoperative angiography, who developed temporary neurologic deterioration after superior sagittal sinus ligation and resection.

비파괴 검사법에 의한 노후터널의 건전도 평가 (Damage Detection of Decrepit Tunnel Structures using the NDT)

  • 김동규;정호섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1388-1391
    • /
    • 2010
  • Recently, the construction of road, subway, railroad, and microtunnel for electricity supplement have been increased because of increasement of traffic in urban area, increasement of industrial transportation, and the network between cities in Korea. The deterioration of tunnel structure may occur by various internal and external factors and particularly, tunnel structures tend to contact with either underground water or harmful ions. Therefore, leakage sometimes occurred through the cracks and joints of concrete lining. The leakage in tunnel may affect the durability of concrete lining. In this study, to evaluate the durability and deterioration of concrete lining in tunnel structures, we were performed the various experiments for compressive strength. Compressive strength obtained from nondestructive inspection and compressive strength test varies according to the concrete lining conditions.

  • PDF

철근의 강종 및 직경 변화에 따른 부식특성에 관한 연구 (A Study on the Characteristics of Reinforcing Steel according to Specification and Diameter)

  • 임재원;지남용;윤상천;최진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.53-58
    • /
    • 2003
  • Concrete structures move wholly with concrete and rebar, so they endure external force, but recently the embedded rebar in concrete has been corroded by environmental, physical and chemical factors, the embedded rebar corrosion influences concrete structure to deteriorate structure capacity. To revaluate effect to deterioration of concrete structure according to corrosion of rebar, the researcher mostly examined into corrosion rebar and complex relation of concrete. In that there are flexural strength deterioration of corrosion concrete structure and the bond strength of concrete. But It has not sufficiently studied about physical characteristic of corrosion rebar itself. In this study I will compare specification of rebar through corrosion experiment with corrosion ratio of rebar according to diameter and revaluate. And will investigate the effect to strength characteristic of rebar according to corrosion ratio.

  • PDF

철근의 강종 및 직경 변화에 따른 부식특성에 관한 연구 (A Study on the Characteristics of Reinforcing Steel according to Specification and Diameter)

  • 임재원;지남용;윤상천;최진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.53-58
    • /
    • 2003
  • Concrete structures move wholly with concrete and rebar, so they endure external force, but recently the embedded rebar in concrete has been corroded by environmental, physical and chemical factors. the embedded rebar corrosion influences concrete structure to deteriorate structure capacity. To revaluate effect to deterioration of concrete structure according to corrosion of rebar, the researcher mostly examined into corrosion rebar and complex relation of concrete. In that there are flexural strength deterioration of corrosion concrete structure and the bond strength of concrete. But It has not sufficiently studied about physical characteristic of corrosion rebar itself. In this study I will compare specification of rebar through corrosion experiment with corrosion ratio of rebar according to diameter and revaluate. And I will investigate the effect to strength characteristic of rebar according to corrosion ratio.

  • PDF

동특성 추정 기법과 신뢰성 해법에 의한 기설교량의 내하력 판정 방법 (A RELIABILITY-BASED CAPACITY RATING OF EXISTING BRIDGES BY INCORPORATING SYSTEM IDENTIFICATION)

  • Cho, Hyo-Nam;Yun, Chung-Bang
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.37-43
    • /
    • 1990
  • This paper develops practical models and methods for the assessment of safety and rating of damaged and/or deteriorated bridges by incorporating a system identification technique for the explicit inclusion of the degree of deterioration or damage and of the actual bridge response. And, based on the proposed model, reliability-based rating methods are proposed as LRFR(Load and Resistance Factor Rating) and system reliability-index rating criteria. The proposed limit state model explicitly accounts for the degree of deterioration or damage in terms of the damage and response factors. The damage factor in the paper is proposed as the ratio of the current stiffness to the intact stiffness. Based on the observation and the results of applications to existing bridges, it may be concluded that the proposed rating models, which explicitly account for the uncertainties and the effects of degree of deterioration or damage based on the system identification technique, provide more realistic and consistent safety-assessment and capacity-rating.

  • PDF

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.